Superior long-term stability of a glucose biosensor based on inserted barrel plating gold electrodes

被引:9
|
作者
Hsu, Cheng-Teng [1 ]
Hsiao, Hung-Chan [1 ]
Fang, Mei-Yen [1 ]
Zen, Jyh-Myng [2 ]
机构
[1] Bionime Corp, Dept Core Tech Res, Taichung 412, Taiwan
[2] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
来源
BIOSENSORS & BIOELECTRONICS | 2009年 / 25卷 / 02期
关键词
Biosensor; Glucose oxidase; Barrel plating gold electrode; Stability; Accuracy; BLOOD-GLUCOSE; OXIDASE; IMMOBILIZATION; ENZYME; CARBON; FABRICATION; MONOLAYER; PALLADIUM; SYSTEMS; DESIGN;
D O I
10.1016/j.bios.2009.07.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Disposable one shot usage blood glucose strips are routinely used in the diagnosis and management of diabetes mellitus and their performance can vary greatly. In this paper we critically evaluated the long-term stability of glucose strips made of barrel plating gold electrodes. Compared to other glucose biosensing platforms of vapor deposited palladium and screen printed carbon electrodes, the proposed glucose biosensor was found to show the best stability among the three biosensing platforms in thermal acceleration experiments at 40 degrees C for 6 months with an average bias of 3.4% at glucose concentrations of 5-20 mM. The precision test of this barrel plating gold glucose biosensor also showed the best performance (coefficients of variation in the range of 1.4-2.4%) in thermal acceleration experiments at 40 degrees C, 50 degrees C and 70 degrees C for 27 days. Error grid analysis revealed that all measurements fell in zone A and zone B. Regression analysis showed no significant difference between the proposed biosensor and the reference method at 99% confidence level. The amperometric glucose biosensor fabricated by inserting two barrel plating gold electrodes onto an injection-molding plastic base followed by immobilizing with a bio-reagent layer and membrane was very impressive with a long-term stability up to 2.5 years at 25 degrees C. Overall, these results indicated that the glucose oxidase/barrel plating gold biosensing platform is ideal for long-term accurate glycemic control. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:383 / 387
页数:5
相关论文
共 50 条
  • [1] Fabrication of a Glucose Biosensor Based on Inserted Barrel Plating Gold Electrodes
    Hsu, Cheng-Teng
    Chung, Hsieh-Hsun
    Tsai, Dong-Mung
    Fang, Mei-Yen
    Hsiao, Hung-Chan
    Zen, Jyh-Myng
    ANALYTICAL CHEMISTRY, 2009, 81 (01) : 515 - 518
  • [2] GLUCOSE BIOSENSOR BASED ON OXYGEN-ELECTRODE .2. LONG-TERM OPERATIONAL STABILITY OF THE RECHARGEABLE GLUCOSE BIOSENSOR
    ATANASOV, P
    WILKINS, E
    ANALYTICAL LETTERS, 1993, 26 (10) : 2079 - 2094
  • [3] A breathable flexible glucose biosensor with embedded electrodes for long-term and accurate wearable monitoring
    Zheng, Hao
    Chen, Hailong
    Pu, Zhihua
    Li, Dachao
    MICROCHEMICAL JOURNAL, 2022, 181
  • [4] A novel approach to improving the accuracy of glucose biosensor: cooperation of FAD-dependent glucose dehydrogenase with barrel-plating An electrodes
    Hsu, C. T.
    Fang, M. Y.
    Wu, M. H.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A43 - A43
  • [5] RECHARGEABLE GLUCOSE ELECTRODES FOR LONG-TERM IMPLANTATION
    XIE, SL
    WILKINS, E
    JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (05): : 375 - 378
  • [6] LONG-TERM RESPONSE OF AN INTEGRATED CARBON-PASTE BASED GLUCOSE BIOSENSOR
    KULYS, J
    HANSEN, HE
    ANALYTICA CHIMICA ACTA, 1995, 303 (2-3) : 285 - 294
  • [7] Glucose biosensor based on graphite electrodes modified with glucose oxidase and colloidal gold nanoparticles
    Natalija German
    Almira Ramanaviciene
    Jaroslav Voronovic
    Arunas Ramanavicius
    Microchimica Acta, 2010, 168 : 221 - 229
  • [8] Glucose biosensor based on graphite electrodes modified with glucose oxidase and colloidal gold nanoparticles
    German, Natalija
    Ramanaviciene, Almira
    Voronovic, Jaroslav
    Ramanavicius, Arunas
    MICROCHIMICA ACTA, 2010, 168 (3-4) : 221 - 229
  • [9] Long-Term Stability of Axonal Boutons in the Mouse Barrel Cortex
    Qiao, Qian
    Ma, Lei
    Li, Wei
    Tsai, Jin-Wu
    Yang, Guang
    Gan, Wen-Biao
    DEVELOPMENTAL NEUROBIOLOGY, 2016, 76 (03) : 252 - 261
  • [10] Long-Term Stability of a Cellulose-Based Glucose Oxidase Membrane
    Yabuki, Soichi
    Iwamoto, Miho
    Hirata, Yoshiki
    MATERIALS, 2014, 7 (02) : 899 - 905