Calculation of per-unit-length parameters for shielded and unshielded twisted pair cables

被引:4
|
作者
Hassoun, F. [1 ]
Tarafi, R. [1 ]
Zeddam, A. [1 ]
机构
[1] Univ Clermont Ferrand, France Telecom R&D RESA FACE, 2,Ave Pierre Marzin, F-22307 Lannion, France
关键词
D O I
10.1109/EMCZUR.2006.214917
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The deployment of multimedia data transmission is increasing, Digital Subscriber Line technology (xDSL) and other systems are widely used on the telecommunication access network. Conveying such services requires higher data rates, consequently higher bandwidths, and operating frequencies. So, the modelling of the cables is essential to study the disturbing electromagnetic phenomena. Analytical expressions for P.U.L. parameters of finite length twisted pair lines are derived, and verified by the measurement in this paper. These expressions give the capacitances and the inductances values in every point of the cable.
引用
收藏
页码:250 / +
页数:3
相关论文
共 50 条