Synthesis and Use of Stable-Isotope-Labeled Internal Standards for Quantification of Phosphorylated Metabolites by LC-MS/MS

被引:62
|
作者
Arrivault, Stephanie [1 ]
Guenther, Manuela [1 ]
Fry, Stephen C. [2 ]
Fuenfgeld, Maximilian M. F. F. [1 ]
Veyel, Daniel [1 ]
Mettler-Altmann, Tabea [1 ]
Stitt, Mark [1 ]
Lunn, John E. [1 ]
机构
[1] Max Planck Inst Mol Plant Physiol, D-14476 Potsdam, Germany
[2] Univ Edinburgh, Sch Biol Sci, Inst Mol Plant Sci, Edinburgh Cell Wall Grp, Edinburgh EH9 3BF, Midlothian, Scotland
关键词
TANDEM MASS-SPECTROMETRY; CHLAMYDOMONAS-REINHARDTII; ELECTROSPRAY-IONIZATION; ARABIDOPSIS-THALIANA; ESCHERICHIA-COLI; HUMAN URINE; SAMPLES; C-13; PURIFICATION; QUANTITATION;
D O I
10.1021/acs.analchem.5b01387
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is a highly specific and sensitive technique for measuring metabolites. However, coeluting components in tissue extracts can interfere with ionization at the interface of the LC and MS/MS phases, causing under- or overestimation of metabolite concentrations. Spiking of samples with known amounts of stable-isotope-labeled internal standards (SIL-IS) allows measurements of the corresponding metabolites to be corrected for such matrix effects. We describe criteria for selection of suitable SIL-IS and report the enzymatic synthesis and purification of nine SIL-IS for hexose-, pentose-, and triose-phosphates, UDP-glucose, and adenosine monophosphate (AMP). Along with commercially available SIL-IS for seven other metabolites, these were validated by LC MS/MS analyses of extracts from leaves, nonphotosynthetic plant tissues, mouse liver, and cells of Chlamydomonas reinhardtii, Escherichia coli and baker's yeast (Saccharomyces cerevisiae). With only a few exceptions, spiking with SIL-IS significantly improved the reproducibility of LC-MS/MS-based metabolite measurements across a wide range of extract dilutions, indicating effective correction for matrix effects by this approach. With use of SIL-IS to correct for matrix effects, LC-MS/MS offers unprecedented scope for reliable determination of photosynthetic and respiratory intermediates in a diverse range of organisms.
引用
收藏
页码:6896 / 6904
页数:9
相关论文
共 50 条
  • [1] Separation of Key Metabolites of the Kynurenine Pathway by Hilic LC-MS/MS with Stable Isotope-Labeled Internal Standards
    Krzyzanowski, Stanislaw
    Smith, Scott
    Jones, A. Daniel
    Brundin, Lena
    [J]. BIOLOGICAL PSYCHIATRY, 2017, 81 (10) : S229 - S230
  • [2] Bio-generation of stable isotope labeled internal standards for absolute and relative quantitation of drug metabolites in plasma samples by LC-MS/MS
    Li, Pei
    Gong, Yong
    Lim, Heng-Keang
    Jian, Wenying
    Edom, Richard W.
    Salter, Rhys
    Silva, Jose
    Weng, Naidong
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 926 : 92 - 100
  • [3] Development, Validation, and Application of a New Method To Correct the Nonlinearity Problem in LC-MS/MS Quantification Using Stable Isotope-Labeled Internal Standards
    Liu, Qian
    Jiang, Fulin
    Zhu, Janshon
    Zhong, Guoping
    Huang, Min
    [J]. ANALYTICAL CHEMISTRY, 2019, 91 (15) : 9616 - 9622
  • [4] Synthesis of Deuterium-Labeled Vitamin D Metabolites as Internal Standards for LC-MS Analysis
    Nagata, Akiko
    Iijima, Kazuto
    Sakamoto, Ryota
    Mizumoto, Yuka
    Iwaki, Miho
    Takiwaki, Masaki
    Kikutani, Yoshikuni
    Fukuzawa, Seketsu
    Odagi, Minami
    Tera, Masayuki
    Nagasawa, Kazuo
    [J]. MOLECULES, 2022, 27 (08):
  • [5] Reliable LC-MS quantitative glycomics using iGlycoMab stable isotope labeled glycans as internal standards
    Zhou, Shiyue
    Tello, Nadia
    Harvey, Alex
    Boyes, Barry
    Orlando, Ron
    Mechref, Yehia
    [J]. ELECTROPHORESIS, 2016, 37 (11) : 1489 - 1497
  • [6] Use of isotope-labeled Aflatoxins for LC-MS/MS stable isotope dilution analysis of foods
    Cervino, Christian
    Asam, Stefan
    Knopp, Dietmar
    Rychlik, Michael
    Niessner, Reinhard
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (06) : 1873 - 1879
  • [7] Simultaneous quantification of 11 antiepileptic drugs using limited isotope-labeled internal standards in LC-MS/MS: An accuracy assessment
    Abady, Mariam M.
    Jeong, Ji-Seon
    Kwon, Ha-Jeong
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1240
  • [8] Potential bias and mitigations when using stable isotope labeled parent drug as internal standard for LC-MS/MS quantitation of metabolites
    Jian, Wenying
    Edom, Richard W.
    Xu, Yaodong
    Gallagher, Joseph
    Weng, Naidong
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (31): : 3267 - 3276
  • [9] Evaluation of a cleavable stable isotope labeled synthetic peptide for absolute protein quantification using LC-MS/MS
    Barnidge, DR
    Hall, GD
    Stocker, JL
    Muddiman, DC
    [J]. JOURNAL OF PROTEOME RESEARCH, 2004, 3 (03) : 658 - 661
  • [10] An extended stable isotope-labeled signature peptide internal standard for tracking immunocapture of human plasma osteopontin for LC-MS/MS quantification
    Faria, Morse
    Halquist, Matthew S.
    Yuan, Moucun
    Mylott, William, Jr.
    Jenkins, Rand G.
    Karnes, H. Thomas
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (11) : 1780 - 1782