Testing of a read-out device processing electronics for IR linear and focal-plane arrays

被引:9
|
作者
Sizov, FF [1 ]
Derkach, YP [1 ]
Kononenko, YG [1 ]
Reva, VP [1 ]
机构
[1] Ukrainian Acad Sci, Inst Semicond Phys, UA-252028 Kiev, Ukraine
关键词
read-out devices; multielement arrays; CCD multiplexers;
D O I
10.1117/12.327995
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For preliminary selection of the silicon read-out devices designed for applications in hybrid mercury-cadmium-telluride (MCT) IR linear or matrix arrays manufactured according to flip-chip technology, there was designed constructions of the testing circuits imbedded into the read-out devices to test them before hybridization. Also the procedure of their testing at room temperature without attachment to the MCT photo-voltaic multielement arrays was developed. There were designed some types of multielement silicon read-out devices with input direct injection and buffered direct injection circuits and charge coupled devices (CCD) multiplexers to be used with n(+)-p- or p(+)-n-photodiodes with dynamical resistance at reverse bias R greater than or equal to 10(7) Omega. Into these read-out devices there were incorporated the testing snitches which attach the sources of direct injection transistors to the common load resistors to imitate the output signal of MCT photodiodes. The silicon read-out devices for 2x64 linear arrays and 2x4x128(144) TDI arrays with direct and buffered direct charge injection were manufactured by n-channel MOS technology with CCD register with buried channel. By changing the frequency of the control impulses here were investigated the characteristics of the read-oct devices for time delay and integration (TDI) arrays in the regime of integration and without it (in TDI channel).
引用
收藏
页码:942 / 948
页数:7
相关论文
共 36 条
  • [1] Readout device processing electronics for IR linear and focal plane arrays.
    Sizova, FF
    Derkach, YP
    Kononenko, YG
    Reva, VP
    [J]. INFRARED TECHNOLOGY AND APPLICATIONS XXV, 1999, 3698 : 816 - 825
  • [2] IR focal-plane arrays enable imaging that is out of this world
    Beletic, James W.
    [J]. LASER FOCUS WORLD, 2007, 43 (10): : 75 - 78
  • [3] Development of an analog and mixed-signal read-out circuit for long-wavelength infrared focal-plane arrays
    Claro, Marcel S.
    Quivy, Alain A.
    [J]. 2016 31ST SYMPOSIUM ON MICROELECTRONICS TECHNOLOGY AND DEVICES (SBMICRO), 2016,
  • [4] NEW HORIZONS FOR IR FOCAL-PLANE ARRAYS
    BOTTS, SE
    [J]. PHOTONICS SPECTRA, 1988, 22 (07) : 125 - &
  • [5] InAsSb and InGaAs linear and focal-plane arrays
    Merken, P
    Zimmermann, L
    John, J
    Németh, S
    Gastal, M
    Borghs, G
    Van Hoof, C
    [J]. INFRARED DETECTORS AND FOCAL PLANE ARRAYS VI, 2000, 4028 : 246 - 251
  • [6] Signal processing of microbolometer infrared focal-plane arrays
    Zhang, JJ
    Qian, YS
    Chang, BK
    Xing, SX
    Sun, LJ
    [J]. INFRARED COMPONENTS AND THEIR APPLICATIONS, 2005, 5640 : 137 - 144
  • [7] A BRIGHT FUTURE FOR SMART STARING IR FOCAL-PLANE ARRAYS
    KING, C
    MASSIE, M
    [J]. PHOTONICS SPECTRA, 1994, 28 (04) : 103 - &
  • [8] Read-out Electronics and Signal Processing in GERDA and Future Prospects
    D'Andrea, Valerio
    [J]. ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2019), 2020, 225
  • [9] INFRARED DETECTOR ARRAYS WITH MULTIPLEXING CRYOGENIC READ-OUT ELECTRONICS FOR ISOPHOT
    ENGEMANN, D
    FAYMONVILLE, R
    FELTEN, R
    FRENZL, O
    MEYER, K
    SOHN, A
    DIERICKX, B
    VERMEIREN, J
    [J]. INFRARED PHYSICS, 1989, 29 (2-4): : 235 - 241
  • [10] CMOS read-out IC with op-amp pixel amplifier for infrared focal plane arrays
    Niewiadomski, JJ
    Carlson, BS
    [J]. TENTH ANNUAL IEEE INTERNATIONAL ASIC CONFERENCE AND EXHIBIT, PROCEEDINGS, 1997, : 69 - 73