共 2 条
Complete Incineration of Diesel Particulate Matter Using Indirect Plasma
被引:0
|作者:
Nishii, Shunsuke
[1
]
Kuwahara, Takuya
[1
]
Kuroki, Tomoyuki
[1
]
Okubo, Masaaki
[1
]
机构:
[1] Osaka Prefecture Univ, Dept Mech Engn, Naka Ku, 1-1 Gakuen Cho, Sakai, Osaka 5998531, Japan
关键词:
EMISSION CONTROL;
D O I:
暂无
中图分类号:
P4 [大气科学(气象学)];
学科分类号:
0706 ;
070601 ;
摘要:
In recent years, the regulations governing diesel engine emissions become more stringent. It is difficult to fulfill these by only combustion improvement technique. Although an indirect plasma method for regenerating a diesel particulate filter (DPF) draws attention as an innovative technique, it is unknown that this technique can achieve a complete DPF regeneration, that is, all collected particulate matter (PM) can be oxidized by nonthermal plasma -induced ozone. In this study, we investigate a possibility of complete DPF regeneration by evaluating pressure differences between inlet and outlet of DPF. As a result, a complete DPF regeneration can be achieved with an ozone injection of 34.8 g/h for 2 hours after collecting PM in the DPF for 2 hours. The series of the PM collection and the DPF regeneration are performed without stopping engine operation.
引用
收藏
页码:151 / 152
页数:2
相关论文