Method to diagnose open-circuit faults in active power switches and clamp-diodes of three-level neutral-point clamped inverters

被引:53
|
作者
Abadi, Mohsen Bandar [1 ]
Santos Mendes, Andre Manuel [1 ]
Angelo Cruz, Sergio Manuel [1 ]
机构
[1] Univ Coimbra, Dept Elect & Comp Engn, Inst Telecomunicacoes, Polo 2 Pinhal Marrocos, P-3030290 Coimbra, Portugal
关键词
invertors; fault diagnosis; insulated gate bipolar transistors; semiconductor diodes; clamps; insulated gate bipolar transistor; clamp-diode; three-level neutral-point clamped inverter; multiple semiconductor open-circuit fault diagnosis; OC; output pole voltage evaluation; output current evaluation; modulation; MULTILEVEL CONVERTERS; MOTOR-DRIVES; INDUSTRIAL APPLICATIONS; VOLTAGE; ALGORITHM; SYSTEMS; VECTOR; ENERGY;
D O I
10.1049/iet-epa.2015.0644
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new real-time method able to diagnose multiple semiconductor open-circuit (OC) faults in a three-level neutral-point clamped inverter is introduced in this paper. The proposed diagnostic method is based on the evaluation of the output pole voltages and output currents of the inverter. The proposed method allows a real-time detection and localisation of multiple OC faults in all active power switches and clamp-diodes within one modulation period. Experimental results obtained for different operating conditions of the inverter demonstrate the applicability and performance of the proposed diagnostic approach.
引用
收藏
页码:623 / 632
页数:10
相关论文
共 50 条
  • [1] Active Neutral-Point Balancing of Three-Level Neutral-Point-Clamped Traction Inverters
    Xu, Huihui
    Bubert, Andreas
    Laumen, Michael
    De Doncker, Rik W.
    [J]. 2018 21ST INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2018, : 2256 - 2261
  • [2] Detection of Open-Circuit Faults in Multi-Level Hybrid Active Neutral Point Clamped Inverters
    Laith M. Halabi
    Ibrahim Mohd Alsofyani
    Kyo-Beum Lee
    [J]. Journal of Electrical Engineering & Technology, 2022, 17 : 2299 - 2307
  • [3] Detection of Open-Circuit Faults in Multi-Level Hybrid Active Neutral Point Clamped Inverters
    Halabi, Laith M.
    Alsofyani, Ibrahim Mohd
    Lee, Kyo-Beum
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2022, 17 (04) : 2299 - 2307
  • [4] Open-Circuit Fault Tolerance Method for Three-Level Hybrid Active Neutral Point Clamped Converters
    Halabi, Laith M.
    Mohd Alsofyani, Ibrahim
    Lee, Kyo-Beum
    [J]. ELECTRONICS, 2020, 9 (09) : 1 - 23
  • [5] A Noninvasive and Robust Diagnostic Method for Open-Circuit Faults of Three-Level Inverters
    Wu, Xun
    Chen, Te-Fang
    Cheng, Shu
    Yu, Tianjian
    Xiang, Chaoqun
    Li, Kaidi
    [J]. IEEE ACCESS, 2019, 7 : 2006 - 2016
  • [6] A New Active Common-Mode Voltage Elimination Method For Three-Level Neutral-Point Clamped Inverters
    Alawieh, H.
    Tehrani, K. Arab
    Azzouz, Y.
    Dakyo, B.
    [J]. IECON 2014 - 40TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2014, : 1060 - 1066
  • [7] An Open-Circuit Fault Diagnosis Method for Three-Level Neutral Point Clamped Inverters Based on Multi-Scale Shuffled Convolutional Neural Network
    Yan, Yan
    Wu, Jiaqi
    Cao, Yanfei
    Liu, Bo
    Li, Chen
    Shi, Tingna
    [J]. SENSORS, 2024, 24 (06)
  • [8] The Zero-Sequence Circulating Current Suppression Method for Parallel Three-Level Rectifiers System Under the Open-Circuit Fault of Neutral-Point Switches
    Chen, Zhiyuan
    Xing, Xiangyang
    Li, Xiaoyan
    Pang, Xianzhe
    Zhang, Chenghui
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2023, 19 (01) : 189 - 199
  • [9] Open-Circuit Fault Diagnosis of Neutral Point Clamped Three-Level Inverter Based on Sparse Representation
    Yu, Yunjun
    Pei, Shilei
    [J]. IEEE ACCESS, 2018, 6 : 73499 - 73508
  • [10] Fault Diagnosis and Tolerant Control of Three-Level Neutral-Point Clamped Inverters in Motor Drives
    Chao, Kuei-Hsiang
    Ke, Chen-Hou
    [J]. ENERGIES, 2020, 13 (23)