Monte Carlo Simulation Affecting PSSD Position Resolution Factors

被引:0
|
作者
Song Haisheng [1 ]
Dong Caixia [1 ,2 ]
Niu Defang [1 ,2 ]
Zhuang Kai [2 ,3 ]
Li Ting [2 ,3 ]
Qin Xiubo [2 ,4 ]
Liu Penghao [2 ]
Yang Xiongbin [2 ]
Xue Yuxiong [5 ]
机构
[1] Northwest Normal Univ, Coll Phys & Elect Engn, Lanzhou 730000, Gansu, Peoples R China
[2] Chinese Acad Sci, Beijing Engn Res Ctr Radiog Tech & Equipment, Inst High Energy Phys, Beijing 100049, Peoples R China
[3] Univ Chinese Acad Sci, Sch Nucl Sci & Technol, Beijing 100049, Peoples R China
[4] China Aerosp Sci & Ind Corp Ltd, Acad 2, X Lab, Beijing 100049, Peoples R China
[5] Lanzhou Inst Phys, Sci & Technol Vacuum & Phys Lab, Lanzhou 730000, Gansu, Peoples R China
关键词
detectors; charged particles; FLUKA; electron; position sensitive silicon detector; position resolution;
D O I
10.3788/LOP202158.0504002
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Based on the theoretical basis of the interaction between particles and matter,the influence of charged particle energy,incident angle,detector thickness,and sensitive area on position sensitive silicon detector(PSSD) position resolution is analyzed by using FLUKA Monte Carlo simulation software. The simulation results show that as the electron energy increases,the position resolution capability of the detector becomes worse. When the electron energy increases to pass through the detector,the position resolution capability gradually increases with the increase of energy. For the detectors of different thickness,when the electron energy is completely deposited in the detector,the position resolution ability of the detector is basically the same. When the electron energy is not completely deposited in the detector,the position resolution ability of the detector with a larger thickness is relatively poor. The limited area of the detector will affect the position resolution. When electrons enter the detector at an incident angle alpha <= 45 degrees,the detected electron position will shift. The larger the incident angle,the more obvious the shift.
引用
收藏
页数:7
相关论文
共 21 条
  • [1] Banu A, 2007, 2007 ANN M DIV NUCL
  • [2] Chen Y H, 2014, STUDY MECH KEY TECHN
  • [3] STUDY OF POSITION RESOLUTION FOR CATHODE READOUT MWPC WITH MEASUREMENT OF INDUCED CHARGE-DISTRIBUTION
    CHIBA, J
    IWASAKI, H
    KAGEYAMA, T
    KURIBAYASHI, S
    NAKAMURA, K
    SUMIYOSHI, T
    TAKEDA, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03): : 451 - 463
  • [4] Dong J, 2009, STUDY 2 DIMENSIONAL
  • [5] Ferrari A., FLUKA MULTIPARTICLE
  • [6] Gao W D, 2016, HIGH SPEED DATA TEST
  • [7] Optimizing the response of Schottky barrier position sensitive detectors
    Henry, J
    Livingstone, J
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2004, 37 (22) : 3180 - 3184
  • [8] Influence of trapping on silicon microstrip detector design and performance
    Kramberger, G
    Cindro, V
    Mandic, I
    Mikuz, M
    Zavrtanik, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1717 - 1723
  • [9] High-Precision Laser Tracking System Based on Two-Dimensional Galvanometers and Position Sensitive Detectors
    Li Guicun
    Fang Yami
    Ji Rongyi
    Zhang Zili
    Zhang Hao
    Mu Jinzhen
    Song Ting
    [J]. CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2019, 46 (07):
  • [10] Li J, 2001, NUCL ELECT DETECTION, V21, P70