DietSee: An on-hand, portable, strip-type biosensor for lipolysis monitoring via real-time amperometric determination of glycerol in blood

被引:5
|
作者
Degrelle, Severine A. [1 ]
Delile, Sebastien [1 ,2 ]
Moog, Sophie [1 ]
Mouisel, Etienne [3 ,4 ]
O'Gorman, Donal [5 ]
Moro, Cedric [3 ,4 ]
Denechaud, Pierre-Damien [3 ,4 ]
Torre, Cyril [1 ,2 ]
机构
[1] Inovarion, 251 Rue St Jacques, F-75005 Paris, France
[2] LSee SAS, F-20090 Ajaccio, France
[3] INSERM, Inst Metab & Cardiovasc Dis, UMR1048, F-31432 Toulouse, France
[4] Paul Sabatier Univ, Univ Toulouse, F-31330 Toulouse, France
[5] Dublin City Univ, Sch Hlth & Human Performance, Dublin, Ireland
关键词
Biosensor; Fat loss management; Glycerometer; Glycerol; Lipolysis; On-hand portable instrument; Point-of-care testing (POCT); FATTY-ACIDS; HEMATOCRIT; METABOLISM;
D O I
10.1016/j.aca.2021.338358
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glycerol is a clinical biomarker of lipolysis that is mainly produced by adipose tissues. Blood glycerol content increases in pathological conditions such as metabolic and cardiovascular diseases or cancer cachexia, but also in response to energetic stress such as physical exercise. Accurate glycerol monitoring is therefore important in a range of healthcare contexts. However, current methods available for the quantification of glycerol are expensive, time-consuming, and require the extraction of plasma from blood, from which blood glycerol content is then extrapolated. Here, we report the development of a new point-of-care glycerometer device, DietSee, based on a strip-type biosensor that enables the quantifi-cation of glycerol directly from whole blood in 6 s. The performance of the biosensor was first evaluated using buffer solutions and spiked human and mouse plasma samples, and its response was compared with that of the gold-standard colorimetric method. The results obtained using DietSee correlated strongly with those from the reference method and demonstrated a linear response to glycerol levels across a wide range of concentrations (40-750 mM) that were representative of those in the human body. Next, the biosensor was validated using spiked human blood samples over a range of 30-55% hemat-ocrit; it also demonstrated a strong correlation with reference measurements under these conditions (R-2 = 0.97). In addition, the biosensor was only minimally affected by a variety of potential interferents (endogenous and exogenous) and was highly stable in storage (more than 2 years when strips were stored dry at 4 degrees C). Finally, we investigated the application of the biosensor to real-time monitoring of lipolysis and found that the DietSee is well adapted for this purpose in both human and mouse samples. To conclude, the novel DietSee glycerometer is a sensitive, selective, and rapid tool that enables characterization of the metabolic status of an individual by measuring the glycerol concentration from a single fingertip blood drop. (C) 2021 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license.
引用
收藏
页数:8
相关论文
共 2 条
  • [1] Mediator-type biosensor for real-time wireless monitoring of blood glucose concentrations in fish
    Takase, Mai
    Yoneyama, Yohei
    Murata, Masataka
    Hibi, Kyoko
    Ren, Huifeng
    Endo, Hideaki
    [J]. FISHERIES SCIENCE, 2012, 78 (03) : 691 - 698
  • [2] Mediator-type biosensor for real-time wireless monitoring of blood glucose concentrations in fish
    Mai Takase
    Yohei Yoneyama
    Masataka Murata
    Kyoko Hibi
    Huifeng Ren
    Hideaki Endo
    [J]. Fisheries Science, 2012, 78 : 691 - 698