Pilot program on patient dosimetry in pediatric interventional cardiology in Chile

被引:28
|
作者
Ubeda, Carlos [1 ,2 ]
Vano, Eliseo [3 ,4 ]
Miranda, Patricia [5 ]
Leyton, Fernando [6 ,7 ]
机构
[1] Tarapaca Univ, Fac Hlth Sci, Radiol Sci Ctr, Dept Clin Sci, Arica, Chile
[2] Tarapaca Univ, CHIDE, Arica, Chile
[3] Univ Complutense, Dept Radiol, E-28040 Madrid, Spain
[4] San Carlos Hosp, Madrid 28040, Spain
[5] Hosp Ninos Luis Calvo Mackenna, Cardiovasc Serv, Hemodynam Dept, Santiago, Chile
[6] Inst Publ Hlth Chile, Santiago, Chile
[7] Diego Portales Univ, Fac Med, Santiago, Chile
关键词
pediatric cardiology; interventional; patient dose; CARDIAC-CATHETERIZATION; RADIATION-EXPOSURE; DETECTOR;
D O I
10.1118/1.3702590
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to present the results of a pilot program on patient dosimetry carried out in Chile during the last 5 yr, using a biplane x-ray angiography system settled for pediatrics. This research was conducted in Latin America under the auspices of the International Atomic Energy Agency (IAEA) supporting programs on radiological protection (RP) of patients. Methods: Patient age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time, and two dosimetric quantities [air kerma-area product (P-ka) and cumulative dose (CD) at the patient entrance reference point] were recorded for each procedure. Results: The study includes 544 patients grouped into four age groups. The distributions by age group were 150 for < 1 yr; 203 for 1 to < 5 yr; 97 for 5 to < 10 yr; and 94 for 10 to < 16 yr. Median values of P-ka and CD for the four age groups were 0.94, 1.46, 2.13, and 5.03 Gy cm(2) and 23.9, 26.8, 33.5, and 51.6 mGy, respectively. No significant statistical differences were found between diagnostic and therapeutic procedures. A moderate correlation (r = 0.64) was seen between P-ka and patient weight. Conclusions: The dose values reported in this paper were lower than those published in the previous work for the same age groups as a result of the optimization actions carried out by cardiologists and medical physicists with the support of the IAEA. Methodology and results will be used as a starting point for a wider survey in Chile and Latin America with the goal to obtain regional diagnostic reference levels as recently recommended by the International Commission on Radiological Protection for interventional procedures. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3702590]
引用
收藏
页码:2424 / 2430
页数:7
相关论文
共 50 条
  • [1] Patient dosimetry during interventional cardiology procedures
    Neofotistou, V
    Karoussou, A
    Lobotesi, H
    Hourdakis, K
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 151 - 154
  • [2] RADIATION PROTECTION IN PEDIATRIC INTERVENTIONAL CARDIOLOGY: AN IAEA PILOT PROGRAM IN LATIN AMERICA
    Vano, Eliseo
    Ubeda, Carlos
    Miranda, Patricia
    Leyton, Fernando
    Duran, Ariel
    Nader, Alejandro
    [J]. HEALTH PHYSICS, 2011, 101 (03): : 233 - 237
  • [3] Patient dosimetry in interventional cardiology at the University Hospital of Osijek
    Faj, Dario
    Steiner, Robert
    Trifunovic, Dejan
    Faj, Zlatan
    Kasabasic, Mladen
    Kubelka, Dragan
    Brnic, Zoran
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 128 (04) : 485 - 490
  • [4] PATIENT SKIN DOSIMETRY IN INTERVENTIONAL CARDIOLOGY IN THE CZECH REPUBLIC
    Sukupova, L.
    Novak, L.
    Kala, P.
    Cervinka, P.
    Stasek, J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 147 (1-2) : 106 - 110
  • [5] Patient skin dosimetry in haemodynamic and electrophysiology interventional cardiology
    Trianni, A
    Chizzola, G
    Toh, H
    Quai, E
    Cragnolini, E
    Bernardi, G
    Proclemer, A
    Padovani, R
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 241 - 246
  • [6] INTERVENTIONAL CARDIOLOGY IN CHILE
    ALCAINO, ME
    ESCOBAR, E
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1995, 8 (01) : 29 - 32
  • [7] Staff dosimetry in interventional cardiology
    Padovani, R
    Rodella, CA
    [J]. RADIATION PROTECTION DOSIMETRY, 2001, 94 (1-2) : 99 - 103
  • [8] Staff dosimetry in interventional cardiology
    Padovani, R
    Rodella, CA
    [J]. DOSE AND IMAGE QUALITY IN DIGITAL IMAGING AND INTERVENTIONAL RADIOLOGY (DIMOND), 2001, : 99 - 103
  • [9] Patient dosimetry approaches in interventional cardiology and literature dose data review
    Padovani, R
    Quai, E
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 217 - 221
  • [10] Interventional pediatric cardiology
    Kretschmar, O.
    Navarini, S.
    Knirsch, W.
    [J]. MONATSSCHRIFT KINDERHEILKUNDE, 2015, 163 (01) : 69 - 81