FRICKE GEL DOSIMETRY FOR THE MEASUREMENT OF THE ANISOTROPY FUNCTION OF AN IR-192 HDR BRACHYTHERAPY SOURCE

被引:0
|
作者
Carrara, M. [1 ]
Gambarini, G. [2 ]
Scotti, A. [2 ]
Pirola, L. [2 ]
Borroni, M. [1 ]
Fallai, C. [3 ]
Cerrotta, A. [3 ]
Olmi, P. [3 ]
Zonca, G. [1 ]
机构
[1] Fdn IRCCS Ist Nazl Tumori, Med Phys, Milan, Italy
[2] Univ Milan, Phys, Milan, Italy
[3] Fdn IRCCS Ist Nazl Tumori, Radiotherapy, Milan, Italy
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
1509
引用
收藏
页码:S516 / S517
页数:2
相关论文
共 50 条
  • [1] FRICKE GEL DOSIMETERS FOR THE MEASUREMENT OF THE ANISOTROPY FUNCTION OF A HDR IR-192 BRACHYTHERAPY SOURCE
    Carrara, M.
    Tomatis, S.
    Zonca, G.
    Gambarini, G.
    Bartesaghi, G.
    Tenconi, C.
    Cerrotta, A.
    Fallai, C.
    [J]. ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 610 - 614
  • [2] Dosimetry of a two new IR-192 source models for HDR and PDR brachytherapy
    Granero, D.
    Perez-Calatayud, J.
    Gimeno, J.
    Gonzalez, V.
    Ballester, F.
    Casal, E.
    Pujades, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S147 - S147
  • [3] Development of An Absorbed Dose to Water Primary Standard for HDR Ir-192 Brachytherapy Based On the Fricke Dosimetry System
    El Gamal, I.
    Cojocaru, C.
    Mainegra-Hing, E.
    Ross, C.
    McEwen, M.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Dosimetry for Ir-192 HDR Brachytherapy - Present Status and Future Direction
    DeWerd, L.
    Seuntjens, J.
    Rivard, M.
    McEwen, M.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3884 - 3885
  • [5] A DOSIMETRIC STUDY OF THE MICROSELECTRON HDR IR-192 BRACHYTHERAPY SOURCE
    Granero, D.
    Rivard, M.
    Ballester, F.
    Perez-Calatayud, J.
    Vijande, J.
    Otal, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S479 - S479
  • [6] A Dosimetric Study of the MicroSelectron HDR Ir-192 Brachytherapy Source
    Granero, D.
    Rivard, M. J.
    Ballester, F.
    Perez-Calatayud, J.
    Vijande, J.
    Otal, A.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [7] Radiochromic film measurement of anisotropy function for high-dose-rate Ir-192 brachytherapy source
    Sharma, SD
    Bianchi, C
    Conte, L
    Novario, R
    Bhatt, BC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (17): : 4065 - 4072
  • [8] Monte Carlo dosimetry study of the flexisource IR-192 HDR source
    Casal, E.
    Granero, D.
    Perez-Calatayud, J.
    Ballester, F.
    Venselaar, J.
    Cases, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S267 - S267
  • [9] Measurement of dosimetric parameters for a new HDR Ir-192 source
    Muller-Runkel, R
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1900 - 1900
  • [10] The non-uniformity correction factor for the cylindrical ionization chambers in dosimetry of an HDR Ir-192 brachytherapy source
    Majumdar, Bishnu
    Patel, Narayan Prasad
    Vijayan, V.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2006, 31 (02) : 83 - 88