The sensitivity and accuracy of a bioanalytical method is critical in defining the pharmacokinetic (PK) parameters of a potential new chemical entity (NCE). Inhaled therapeutics and low dose NCEs present one of the most significant analytical challenges to the bioanalyst, due to their low systemic concentration. The sensitivity of a bioanalytical LC/MS/MS based assay can be influenced by multiple parameters, including: mobile phase composition, extraction efficiency and chromatographic performance. In this work, we discuss the influence of acidic (pH 3), and basic (pH 10) aqueous mobile phases in conjunction with the two most common organic modifiers used in HPLC, acetonitrile and methanol, on the assay sensitivity of twenty-four probe pharmaceuticals in solvent and biological fluid extract. The study showed that when the test probe pharmaceuticals were analyzed with basic aqueous mobile phases compared to standard acidic conditions the following results were observed: increases in chromatographic peak area ranging from 1.2 to 9.6 fold for twenty-one of the test compounds as well as increased signal-to-noise for greater than seventy percent of the compounds. This observed increase in the MS response was not necessarily related to the later elution of the analyte in a higher organic composition under basic conditions. This was demonstrated as seven out of the twenty-four (approximately thirty percent) of the probe pharmaceuticals tested, eluted earlier, or with the same retention time, under basic conditions, and still produced a greater signal-to-noise when analyzed under these basic conditions. Also observed were decreases in chromatographic peak width, and increases in the retention time of very hydrophilic pharmaceutical compounds. The effect of the mobile phase combinations on the retention and MS response of the choline-containing phospholipids present in precipitated plasma was also investigated, as these analytes are a major source of interference when developing a bioanalytical assay. Published by Elsevier B.V.
引用
收藏
页码:138 / 150
页数:13
相关论文
共 14 条
  • [1] Investigation of microbore UPLC and nontraditional mobile phase compositions for bioanalytical LC-MS/MS
    Rainville, Paul D.
    Simeone, Jennifer L.
    McCarthy, Sean M.
    Smith, Norman W.
    Cowan, David
    Plumb, Robert S.
    [J]. BIOANALYSIS, 2012, 4 (11) : 1287 - 1297
  • [2] Investigation of basic mobile phases with positive ESI LC-MS for metabonomics studies
    Rainville, Paul D.
    Smith, Norman W.
    Cowan, David
    Nicholson, Jeremy K.
    Shockcor, J. P.
    Skilton, St John
    Plumb, Robert S.
    [J]. BIOANALYSIS, 2012, 4 (23) : 2833 - 2842
  • [3] Effect of the Mobile Phase Compositions on the Confirmation Analysis of Some Prohibited Substances in Sport by LC–ESI–MS/MS
    Ebru Uçaktürk
    Arif Ahmet Başaran
    Ali Haydar Demirel
    [J]. Chromatographia, 2020, 83 : 1397 - 1411
  • [4] Effect of the Mobile Phase Compositions on the Confirmation Analysis of Some Prohibited Substances in Sport by LC-ESI-MS/MS
    Ucakturk, Ebru
    Basaran, Arif Ahmet
    Demirel, Ali Haydar
    [J]. CHROMATOGRAPHIA, 2020, 83 (11) : 1397 - 1411
  • [5] Influence of mobile phase composition on the analytical sensitivity of LC-ESI-MS/MS for the concurrent analysis of bisphenols, parabens, chlorophenols, benzophenones, and alkylphenols
    Lee, Kang Mi
    Han, Sang Moon
    Lee, Hyeon-Jeong
    Kang, Minsik
    Jeong, Tae Young
    Son, Junghyun
    Min, Hophil
    Cha, Sangwon
    Oh, Han Bin
    Oh, Won Keun
    Lee, Jaeick
    [J]. ENVIRONMENTAL RESEARCH, 2023, 221
  • [6] Mobile phase pH and organic modifier in reversed-phase LC-ESI-MS bioanalytical methods: assessment of sensitivity, chromatography and correlation of retention time with in silico logD predictions
    Silvester, Steve
    [J]. BIOANALYSIS, 2013, 5 (22) : 2753 - 2770
  • [7] Effect of high pH mobile phase on the sensitivity of multiple drugs by LC positive electrospray ionization MS/MS
    Mess, Jean-Nicholas
    Lahaie, Mathieu
    Furtado, Milton
    Garofolo, Fabio
    [J]. BIOANALYSIS, 2009, 1 (08) : 1419 - 1429
  • [8] Use of basic mobile phase to improve chromatography and boost sensitivity for quantifying tetrahydrocurcumin in human plasma by LC-MS/MS
    Tan, Aimin
    Wu, Yanxin
    Wong, Molly
    Licollari, Albert
    Bolger, Gordon
    Fanaras, John C.
    Shopp, George
    Helson, Lawrence
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1028 : 86 - 93
  • [9] Sensitivity enhancement in LC-ESI-MS method using mobile phase additives to quantify Simalikalactone E
    Le, H. L.
    Jullian, V
    Bourdy, G.
    Girardi, C.
    Deharo, E.
    Le Lamer, A. C.
    Fabre, N.
    [J]. PLANTA MEDICA, 2012, 78 (11) : 1198 - 1198
  • [10] Enhanced Sensitivity for the Analysis of Perfluoroethercarboxylic Acids Using LC-ESI-MS/MS: Effects of Probe Position, Mobile Phase Additive, and Capillary Voltage
    Brase, Richard A.
    Spink, David C.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (10) : 2124 - 2132