Presurgical assessment of flow variability in an azygos vein aneurysm using 4D-flow MRI

被引:1
|
作者
Ikushima, Takuya [1 ,2 ]
Ujiie, Hideki [1 ,2 ]
Tsuneta, Satonori [3 ]
Chiba, Ryohei [1 ,2 ]
Tabata, Yukiko [1 ,2 ]
Fujiwara-Kuroda, Aki [1 ,2 ]
Hida, Yasuhiro [1 ,2 ]
Kaga, Kichizo [1 ,2 ]
Wakasa, Satoru [1 ,2 ]
Kato, Tatsuya [1 ,2 ]
机构
[1] Hokkaido Univ, Fac Med, Dept Cardiovasc & Thorac Surg, Kita Ku, Kita 15,Nishi 7, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Kita Ku, Kita 15,Nishi 7, Sapporo, Hokkaido 0608638, Japan
[3] Hokkaido Univ Hosp, Dept Diagnost & Intervent Radiol, Sapporo, Hokkaido, Japan
关键词
4D-flow MRI; Azygos vein aneurysm;
D O I
10.1007/s11748-022-01813-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Azygos vein aneurysm (AVA) is necessary to prevent pulmonary embolism due to the outflow of a thrombus or rupture of the aneurysm. However, there is no established modality to assess the properties of AVA. Time-resolved three-dimensional phase-contrast magnetic resonance imaging (4D-flow MRI) has been used to examine the hemodynamics in various fields. We report a case of AVA to evaluate the flow variability and adhesions of surrounding tissues using 4D-flow MRI. The findings of the study suggested aneurysm turbulence and the absence of thrombi. The cine image, which showed a sliding wall synchronized to the heartbeat, indicated no adhesion to the superior vena cava. Based on these results, the thoracoscopic approach was deemed possible preoperatively. Thoracoscopic AVA resection was performed, and the postoperative course was uneventful. This study documented the utility of 4D-flow MRI for a detailed evaluation of AVA.
引用
收藏
页码:673 / 676
页数:4
相关论文
共 50 条
  • [1] Presurgical assessment of flow variability in an azygos vein aneurysm using 4D-flow MRI
    Takuya Ikushima
    Hideki Ujiie
    Satonori Tsuneta
    Ryohei Chiba
    Yukiko Tabata
    Aki Fujiwara-Kuroda
    Yasuhiro Hida
    Kichizo Kaga
    Satoru Wakasa
    Tatsuya Kato
    General Thoracic and Cardiovascular Surgery, 2022, 70 : 673 - 676
  • [2] 4D-Flow MRI: Technique and Applications
    Straeter, Alexandra
    Huber, Armin
    Rudolph, Jan
    Berndt, Maria
    Rasper, Michael
    Rummeny, Ernst J.
    Nadjiri, Jonathan
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2018, 190 (11): : 1025 - 1035
  • [3] In Vitro Assessment of Flow Variability in an Intracranial Aneurysm Model Using 4D Flow MRI and Tomographic PIV
    Rafael Medero
    Katrina Falk
    David Rutkowski
    Kevin Johnson
    Alejandro Roldán-Alzate
    Annals of Biomedical Engineering, 2020, 48 : 2484 - 2493
  • [4] 4D-Flow MRI: Beyond the Images
    Sergio, Pietro
    Miceli, Antonio
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2020, 32 (01) : 35 - 35
  • [5] Correction: In Vitro Assessment of Flow Variability in an Intracranial Aneurysm Model Using 4D Flow MRI and Tomographic PIV
    Rafael Medero
    Katrina Falk
    David Rutkowski
    Kevin Johnson
    Alejandro Roldán-Alzate
    Annals of Biomedical Engineering, 2023, 51 : 457 - 457
  • [6] Intracranial aneurysm instability prediction model based on 4D-Flow MRI and HR-MRI
    Peng, Fei
    Xia, Jiaxiang
    Zhang, Fandong
    Lu, Shiyu
    Wang, Hao
    Li, Jiashu
    Liu, Xinmin
    Zhong, Yao
    Guo, Jiahuan
    Duan, Yonghong
    Sui, Binbin
    Ye, Chuyang
    Ju, Yi
    Kang, Shuai
    Yu, Yizhou
    Feng, Xin
    Zhao, Xingquan
    Li, Rui
    Liu, Aihua
    NEUROTHERAPEUTICS, 2025, 22 (01)
  • [7] Intracranial aneurysm stiffness assessment using 4D Flow MRI
    Koizumi, Satoshi
    Kin, Taichi
    Sekine, Tetsuro
    Kiyofuji, Satoshi
    Umekawa, Motoyuki
    Saito, Nobuhito
    JOURNAL OF NEURORADIOLOGY, 2024, 51 (06)
  • [8] Post-stenotic Helical Aortic Flow on 4D-flow MRI
    Yoshihara, Shu
    Terada, Masaki
    Kamiya, Masaki
    Takehara, Yasuo
    INTERNAL MEDICINE, 2015, 54 (13) : 1669 - 1670
  • [9] In VitroAssessment of Flow Variability in an Intracranial Aneurysm Model Using 4D Flow MRI and Tomographic PIV
    Medero, Rafael
    Ruedinger, Katrina
    Rutkowski, David
    Johnson, Kevin
    Roldan-Alzate, Alejandro
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (10) : 2484 - 2493
  • [10] Hemodynamic assessments of venous pulsatile tinnitus using 4D-flow MRI
    Li, Yunduo
    Chen, Huijun
    He, Le
    Cao, Xiangyu
    Wang, Xianling
    Chen, Shubin
    Li, Rui
    Yuan, Chun
    NEUROLOGY, 2018, 91 (06) : E586 - E593