Development of patient-specific 3D models from histopathological samples for applications in radiation therapy

被引:5
|
作者
DeCunha, Joseph M. [1 ]
Poole, Christopher M. [2 ]
Vallieres, Martin [3 ]
Torres, Jose [4 ]
Camilleri-Broet, Sophie [4 ]
Rayes, Roni F. [5 ]
Spicer, Jonathan D. [5 ]
Enger, Shirin A. [1 ,6 ,7 ]
机构
[1] McGill Univ, Fac Med, Dept Oncol, Med Phys Unit, Montreal, PQ, Canada
[2] Radiat Analyt Pty Ltd, Sunshine Coast, Australia
[3] Univ Sherbrooke, Dept Comp Sci, Sherbrooke, PQ, Canada
[4] McGill Univ, Fac Med, Dept Pathol, Montreal, PQ, Canada
[5] McGill Univ, Canc Res Program, Dept Surg, Div Upper GI & Thorac Surg,Res Inst,Hlth Ctr, Montreal, PQ, Canada
[6] McGill Univ, Res Inst, Hlth Ctr, Montreal, PQ, Canada
[7] Jewish Gen Hosp, Lady Davis Inst Med Res, Montreal, PQ, Canada
关键词
Histopathology; Cellular dosimetry; Patient-specific; Microdosimetry; VOLUME FRACTION;
D O I
10.1016/j.ejmp.2020.12.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The biological effects of ionizing radiation depend on the tissue, tumor type, radiation quality, and patient-specific factors. Inter-patient variation in cell/nucleus size may influence patient-specific dose response. However, this variability in dose response is not well investigated due to lack of available cell/nucleus size data. The aim of this study was to develop methods to derive cell/nucleus size distributions from digital images of 2D histopathological samples and use them to build digital 3D models for use in cellular dosimetry. Nineteen of sixty hematoxylin and eosin stained lung adenocarcinoma samples investigated passed exclusion criterion to be analyzed in the study. A difference of gaussians blob detection algorithm was used to identify nucleus centers and quantify cell spacing. Hematoxylin content was measured to determine nucleus radius. Pouring simulations were conducted to generate one-hundred 3D models containing volumes of equivalent cell spacing and nuclei radius to those in histopathological samples. The nuclei radius distributions of non-tumoral and cancerous regions appearing in the same slide were significantly different (p < 0.01) in all samples analyzed. The median nuclear-cytoplasmic ratio was 0.36 for non-tumoral cells and 0.50 for cancerous cells. The average cellular and nucleus packing densities in the 3D models generated were 65.9% (SD: 1.5%) and 13.3% (SD: 0.3%) respectively. Software to determine cell spacing and nuclei radius from histopathological samples was developed. 3D digital tissue models containing volumes with equivalent cell spacing, nucleus radius, and packing density to cancerous tissues were generated.
引用
收藏
页码:162 / 169
页数:8
相关论文
共 50 条
  • [1] Development of a patient-specific 3D dose evaluation program for QA in radiation therapy
    Suk Lee
    Kyung Hwan Chang
    Yuan Jie Cao
    Jang Bo Shim
    Dae Sik Yang
    Young Je Park
    Won Sup Yoon
    Chul Yong Kim
    Journal of the Korean Physical Society, 2015, 66 : 859 - 866
  • [2] Development of a patient-specific 3D dose evaluation program for QA in radiation therapy
    Lee, Suk
    Chang, Kyung Hwan
    Cao, Yuan Jie
    Shim, Jang Bo
    Yang, Dae Sik
    Park, Young Je
    Yoon, Won Sup
    Kim, Chul Yong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (06) : 859 - 866
  • [3] Applications of patient-specific 3D printing in medicine
    Heller, M.
    Bauer, H-K.
    Goetze, E.
    Gielisch, M.
    Roth, K. E.
    Maier, G. S.
    Drees, P.
    Dorweiler, B.
    Ghazy, A.
    Neufurth, M.
    Mueller, W. E. G.
    Schoerder, H. C.
    Wang, X. H.
    Vahl, C-F
    Al-Nawas, B.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2016, 19 (04) : 323 - 339
  • [4] The development of patient-specific 3D anatomical models in minimally invasive parathyroidectomy
    Haq, Zahra J.
    Ahmed, Ahmed
    Abdelsalam, Alaa
    Chegini, Soudeh
    Kurzawinski, Tom R.
    Morley, Simon
    Mcgurk, Mark
    Abdel-Aziz, Tarek
    FRONTIERS IN ENDOCRINOLOGY, 2024, 15
  • [5] A 3D Patient-Specific Collision Avoidance System for Radiation Therapy Treatment Planning
    Fritscher, K.
    Mehrwald, M.
    Steininger, P.
    Sedlmayer, F.
    Deutschmann, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S746 - S746
  • [6] Development of Patient-Specific 3D Dose Evaluation Solution for Dose-Guided Adaptive Radiation Therapy
    Lee, S.
    Chang, K.
    Shim, J.
    Cao, Y.
    Shin, N.
    Choi, S.
    Jeong, H.
    Yu, S.
    Park, Y.
    Kim, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S703 - S703
  • [7] Semantic Annotation of Patient-Specific 3D Anatomical Models
    Banerjee, Imon
    Agibetov, Asan
    Catalano, Chiara Eva
    Patane, Giuseppe
    Spagnuolo, Michela
    2015 INTERNATIONAL CONFERENCE ON CYBERWORLDS (CW), 2015, : 22 - 29
  • [8] Patient-specific 3D Models for Autogenous Ear Reconstruction
    Witek, Lukasz
    Khouri, Kimberly S.
    Coelho, Paulo G.
    Flores, Roberto L.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2016, 4 (10)
  • [9] 3D Modelling and Printing Technology to Produce Patient-Specific 3D Models
    Birbara, Nicolette S.
    Otton, James M.
    Pather, Nalini
    HEART LUNG AND CIRCULATION, 2019, 28 (02): : 302 - 313
  • [10] The technique for 3D printing patient-specific models for auricular reconstruction
    Flores, Roberto L.
    Liss, Hannah
    Raffaelli, Samuel
    Humayun, Aiza
    Khouri, Kimberly S.
    Coelho, Paulo G.
    Witek, Lukasz
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (06) : 937 - 943