Current status of eye-lens dosimetry in Canada

被引:3
|
作者
Dubeau, Jacques [1 ]
Sun, Jiansheng [2 ]
Djeffal, Salah [3 ]
Leroux, Neil [2 ]
Golovko, Victor [2 ]
Dodkin, Christina [3 ]
Mistry, Rajesh [3 ]
机构
[1] Detec, Gatineau, PQ, Canada
[2] Canadian Nucl Labs, Dosimetry Serv, Chalk River, ON, Canada
[3] Canadian Nucl Safety Commiss, Radiat Protect Div, Ottawa, ON, Canada
关键词
eye-lens; dose limit; dosimetry; H-P(3) CONVERSION COEFFICIENTS; IRPA TASK GROUP; DOSE-EQUIVALENT; AIR KERMA; NEUTRONS; ROSPEC; SPECTROMETRY; PROTECTION;
D O I
10.1088/1361-6498/ac34a1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For occupational exposures in planned exposure situations International Commission on Radiological Protection (ICRP) publication 118 recommends an equivalent dose limit for the lens of the eye of 20 mSv yr(-1) averaged over five years with no single year exceeding 50 mSv. This constitutes a reduction from the previous limit of 150 mSv yr(-1). The Canadian nuclear regulator, the Canadian Nuclear Safety Commission, responded to the ICRP recommendation by initiating amendments to the Radiation Protection Regulations through a discussion paper which was published for comment by interested stakeholders in 2013. The revised equivalent dose limit of 50 mSv in a one-year dosimetry period for nuclear energy workers came into effect in January 2021. This paper presents the outcome of discussions with Canadian stakeholders in diverse fields of radiological work which focused on the implementation of the reduced occupational equivalent dose limit for the lens of the eye in their respective workplaces. These exchanges highlighted the existing practices for monitoring doses to the lens of the eye and identified current technological gaps. The exchanges also identified that, in many cases, the lens of the eye dose is anticipated to be well within the new dose limit despite some of the gaps in technology. The paper also presents the monitoring and eye-lens dose assessment solutions that are available based on different methods for eye-lens monitoring; presented together with criteria for their use.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Implementation of eye-lens dosimetry in Poland
    Szumska, Agnieszka
    Budzanowski, Maciej
    Milcewicz-Mika, Izabela
    Kope, Renata
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 170
  • [2] What is the status of your eye-lens?
    Ganci, Salvatore
    [J]. OPTIK, 2013, 124 (11): : 1014 - 1014
  • [3] COCARCINOGEN IN EYE-LENS OF FISH
    BON, WF
    [J]. ACTA MORPHOLOGICA NEERLANDO-SCANDINAVICA, 1972, 10 (03) : 223 - 232
  • [4] Visual effects of eye-lens fluorescence
    Den Berg, TJ
    Coppens, JE
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U463 - U463
  • [5] Visual effects of eye-lens fluorescence
    van den Berg, T. J. T. P.
    [J]. PERCEPTION, 2000, 29 : 97 - 98
  • [6] BIOCHEMICAL ASPECTS OF EYE-LENS DEVELOPMENT
    RANA, M
    MAISEL, H
    [J]. ANATOMICAL RECORD, 1968, 160 (02): : 413 - &
  • [7] A New Software for the Calculation of Eye-lens Dosimetry Quantities Based on Dose-rate Coefficients
    Dubeau, Jacques
    Sun, Jiansheng
    [J]. HEALTH PHYSICS, 2023, 125 (05): : 383 - 392
  • [8] THE OPTICS OF THE EYE-LENS AND LENTICULAR SENESCENCE - A REVIEW
    PIERSCIONEK, BK
    WEALE, RA
    [J]. DOCUMENTA OPHTHALMOLOGICA, 1995, 89 (04) : 321 - 335
  • [9] ELECTRON EYE-LENS OPERATIONAL DOSE COEFFICIENTS
    Dubeau, J.
    Sun, J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 188 (03) : 372 - 377
  • [10] AN ELECTROPHORETIC STUDY OF AVIAN EYE-LENS PROTEINS
    SIBLEY, CG
    BRUSH, AH