Noninvasive three-dimensional electrocardiographic imaging of ventricular activation sequence

被引:54
|
作者
Zhang, X
Ramachandra, I
Liu, ZM
Muneer, B
Pogwizd, SM
He, B
机构
[1] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN 55455 USA
[2] Univ Illinois, Cardiol Sect, Chicago, IL 60680 USA
关键词
mapping; imaging; electrophysiology; arrhythmia; catheter ablation;
D O I
10.1152/ajpheart.00639.2005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Noninvasive three-dimensional electrocardiographic imaging of ventricular activation sequence. Am J Physiol Heart Circ Physiol 289: H2724-H2732, 2005. First published August 5, 2005; doi:10.1152/ajpheart. 00639.2005. -Imaging the myocardial activation sequence is critical for improved diagnosis and treatment of life-threatening cardiac arrhythmias. It is desirable to reveal the underlying cardiac electrical activity throughout the three-dimensional (3-D) myocardium (rather than just the endocardial or epicardial surface) from noninvasive body surface potential measurements. A new 3-D electrocardiographic imaging technique (3-DEIT) based on the boundary element method (BEM) and multiobjective nonlinear optimization has been applied to reconstruct the cardiac activation sequences from body surface potential maps. Ultrafast computerized tomography scanning was performed for subsequent construction of the torso and heart models. Experimental studies were then conducted, during left and right ventricular pacing, in which noninvasive assessment of ventricular activation sequence by means of 3-DEIT was performed simultaneously with 3-D intracardiac mapping ( up to 200 intramural sites) using specially designed plunge-needle electrodes in closed-chest rabbits. Estimated activation sequences from 3-DEIT were in good agreement with those constructed from simultaneously recorded intracardiac electrograms in the same animals. Averaged over 100 paced beats (from a total of 10 pacing sites), total activation times were comparable (53.3 +/- 8.1 vs. 49.8 +/- 5.2 ms), the localization error of site of initiation of activation was 5.73 +/- 1.77 mm, and the relative error between the estimated and measured activation sequences was 0.32 +/- 0.06. The present experimental results demonstrate that the 3-D paced ventricular activation sequence can be reconstructed by using noninvasive multisite body surface electrocardiographic measurements and imaging of heart-torso geometry. This new 3-D electrocardiographic imaging modality has the potential to guide catheter-based ablative interventions for the treatment of life-threatening cardiac arrhythmias.
引用
收藏
页码:H2724 / H2732
页数:9
相关论文
共 50 条
  • [1] Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardia
    Han, Chengzong
    Pogwizd, Steven M.
    Killingsworth, Cheryl R.
    He, Bin
    [J]. HEART RHYTHM, 2011, 8 (08) : 1266 - 1272
  • [2] Noninvasive Three-dimensional Cardiac Activation Imaging of Ventricular Arrhythmias in the Rabbit Heart
    Han, Chengzong
    Pogwizd, Steven M.
    Killingsworth, Cheryl R.
    Yan, Jiajie
    He, Bin
    [J]. COMPUTING IN CARDIOLOGY 2010, VOL 37, 2010, 37 : 125 - 127
  • [3] Noninvasive Three-dimensional Cardiac Activation Imaging of Ventricular Tachycardia in the Rabbit Heart
    Han, Chengzong
    Pogwizd, Steven
    Killingsworth, Cheryl
    Yan, Jiajie
    He, Bin
    [J]. CIRCULATION, 2010, 122 (21)
  • [4] Noninvasive Reconstruction of the Three-dimensional Ventricular Activation Sequence during Pacing and Ventricular Tachycardia in the Rabbit Heart
    Han, Chengzong
    Pogwizd, Steven M.
    Killingsworth, Cheryl R.
    He, Bin
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 1684 - 1687
  • [5] Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the canine heart
    Han, Chengzong
    Pogwizd, Steven M.
    Killingsworth, Cheryl R.
    He, Bin
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2012, 302 (01): : H244 - H252
  • [6] Three-dimensional electrocardiographic imaging
    He, B
    [J]. PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 5320 - 5320
  • [7] Three-Dimensional Noninvasive Imaging of Ventricular Arrhythmias in Patients With Premature Ventricular Contractions
    Yu, Long
    Jin, Qi
    Zhou, Zhaoye
    Wu, Liqun
    He, Bin
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (07) : 1495 - 1503
  • [8] Noninvasive Three-dimensional Cardiac Activation Imaging on a Rabbit Model
    Han, Chengzong
    Liu, Chenguang
    Pogwizd, Steven
    He, Bin
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3271 - 3273
  • [9] Three-dimensional activation sequence imaging in a rabbit model
    Han, Chengzong
    Liu, Zhongming
    Liu, Chenguang
    Pogwizd, Steven
    He, Bin
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 5609 - +
  • [10] Noninvasive three-dimensional activation time imaging of ventricular excitation by means of a heart-excitation model
    He, B
    Li, GL
    Zhang, X
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22): : 4063 - 4078