Design and Preliminary Testing of a Novel Dual-Chambered Syringe

被引:2
|
作者
May-Newman, Karen [1 ]
Matyska, Maria T. [2 ]
Lee, Martin N. [3 ]
机构
[1] San Diego State Univ, Dept Mech Engn, Bioengn Program, San Diego, CA 92181 USA
[2] San Jose State Univ, San Jose, CA 95192 USA
[3] Preventiv Inc, Sacramento, CA USA
关键词
TENSION; WATER;
D O I
10.1115/1.4003822
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intravenous catheterization is the most common invasive medical procedure today and is designed to introduce medication directly into the blood stream. Common practice is to administer medicine with one syringe, followed by a saline flush to clear the line of any residual medication. The risk of infection due to the introduction of bacteria in the catheter hub is increased with the number of times the hub is accessed. In addition, the two-step process adds millions of nursing hours per year and is prone to error. The goal of this effort was to design and test a dual-chamber syringe that could be reliably used for both dispensing medicine and the saline flush, and be produced at a low cost. The syringe has a novel dual-chamber design with a proximal chamber for medicine and a distal chamber that contains saline. The saline chamber has a fixed volume when the handle is locked into position, which allows the handle to control the variable volume of the medicine chamber. Between the two chambers is a plunger that surrounds the small channel (which is an extension of the distal chamber) that separates the saline from the medicine. When the distal chamber is unlocked, the handle controls the volume of the saline chamber. By this mechanism, the syringe is able inject the medicine followed by the saline flush with a single access to the catheter hub. The smooth operation of the device relies on a locking mechanism to control the rear plunger and volume of the distal saline chamber, and a bubble plug residing in the small channel between the chambers that prevents mixing of the medicine and saline fluids. The bubble plug is held in place by a balance of forces that depend on geometric variables and fluid properties. The chosen design prevents mixing of the two fluids during the operation of the device, which was experimentally validated with mass spectrometry. The dual-chamber syringe has successfully achieved the design goal of a single syringe for the two-step catheter procedure of dispensing medicine and a saline flush. This novel design will reduce the potential for catheter-based infection, medical errors, medical waste, and clinician time. Preliminary test results indicate that this innovation can significantly improve the safety and efficiency of catheter-based administration of medicine. [DOI: 10.1115/1.4003822]
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Design and Preliminary Testing of a Novel Dual-Chambered Syringe (vol 5, 021003, 2011)
    May-Newman, Karen
    Matyska, Maria T.
    Lee, Martin N.
    [J]. JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2011, 5 (03):
  • [2] A DUAL-CHAMBERED SYRINGE THAT ALLOWS IDENTIFICATION OF THE EPIDURAL SPACE USING THE LOSS OF RESISTANCE TECHNIQUE WITH AIR AND WITH SALINE
    CANDIDO, KD
    WINNIE, AP
    [J]. REGIONAL ANESTHESIA, 1992, 17 (03) : 163 - 165
  • [3] A Dual-Chambered Hemodialyzer for Convection-Enhanced Hemodialysis
    Lee, Kyungsoo
    Mun, Cho Hae
    Min, Byoung Goo
    Won, Yong Soon
    [J]. ARTIFICIAL ORGANS, 2012, 36 (03) : E78 - E82
  • [4] DUAL-CHAMBERED VIALS SHOULD CARRY WARNINGS ON LABEL
    GARDNER, SN
    DAVIS, HM
    [J]. AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1989, 46 (08): : 1548 - 1548
  • [5] BEHAVIOR OF LACTATING RATS IN A DUAL-CHAMBERED MATERNITY CAGE
    GROTA, LJ
    ADER, R
    [J]. HORMONES AND BEHAVIOR, 1974, 5 (04) : 275 - 282
  • [6] Dual-chambered membrane bioreactor for coculture of stratified cell populations
    Navarro, Javier
    Swayambunathan, Jay
    Janes, Morgan Elizabeth
    Santoro, Marco
    Mikos, Antonios G.
    Fisher, John P.
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2019, 116 (12) : 3253 - 3268
  • [7] Cathodic reducing bacteria of dual-chambered microbial fuel cell
    Zhang, Guodong
    Feng, Sansan
    Jiao, Yan
    Lee, Duu-Jong
    Xin, Yanjun
    Sun, Huifang
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (45) : 27607 - 27617
  • [8] NEW CONCEPT IN CIRCULATORY ASSISTANCE - DUAL-CHAMBERED INTRAAORTIC BALLOON
    BREGMAN, D
    GOETZ, RH
    [J]. MOUNT SINAI JOURNAL OF MEDICINE, 1972, 39 (02): : 123 - &
  • [9] A Novel Computational Platform for Steady-State and Dynamic Simulation of Dual-Chambered Microbial Fuel Cell
    Naseer, Muhammad Nihal
    Zaidi, Asad A.
    Dutta, Kingshuk
    Jaafar, Juhana
    Wahab, Yasmin Abdul
    Cai, Yuhang
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (09)
  • [10] Sick sinus syndrome in a dog: Treatment with dual-chambered pacemaker implantation
    Burrage, Heather
    [J]. CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2012, 53 (05): : 565 - 568