Impact of transverse magnetic fields on water equivalent ratios in carbon-ion radiotherapy

被引:3
|
作者
Akbari, M. [1 ]
Karimian, A. [2 ]
机构
[1] Univ Isfahan, Dept Nucl Engn, Hezar Jarib St, Esfahan, Iran
[2] Univ Isfahan, Dept Biomed Engn, Hezar Jarib St, Esfahan, Iran
关键词
Dosimetry concepts and apparatus; Radiotherapy concepts; Instrumentation for heavyion therapy; Models and simulations; THERAPY; PROTON; FLUKA; THICKNESS; BEAMS; CODE;
D O I
10.1088/1748-0221/15/05/T05006
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The correct estimation of water equivalent ratio (WER) and the associated errors is highly important for the delivery of carbon-ion (C-ion) beams. In the case of MRI-guided C-ion radiotherapy (MRgCT) scenario, as a therapeutic approach for future potential MR-guided particle therapy, C-ion beam will be deflected in the presence of the magnetic field. The curvature of the track causes a retraction of the range. This range variation might be different in various materials, which leads to change the WER values. To evaluate the WER variations versus magnetic field strength, in this research work, WER of some materials, including bladder, brain, prostate, muscle, bone, polymethylmethacrylate (PMMA), polyoxymethylene (POM), polyethyleneterephthalate (PET), titanium (Ti), gold (Au), platinum (Pt); potentially encountered in C-ion radiotherapy dosimetry were assessed. A mono-energetic C-ion beam, incident on a volume containing materials as mentioned above, was simulated using the FLUKA Monte Carlo code. To validate the simulated C-ion beams, the ion ranges in the water at the calculated energies (100-400 MeV/n) were compared with experimental and analytical data reported in the literature. Moreover, the calculated WER results were compared with available experimental data in the absence of the magnetic field. The WER values were calculated for the materials mentioned above in the presence of 0.35, 1.5, and 3 T magnetic fields and compared to the case without a magnetic field. Good agreement with the experimental data regarding range prediction in water was achieved. No change in the WER value was observed at 100 MeV/n and 0.35 T for all the studied materials and energies. In the case of bladder, brain, and prostate, and muscle materials, no change in WER values was observed by changing the magnetic field strength up to 3 T at the range of the studied energies. The maximum change in WER values by applying the magnetic fields is relevant to the Ti material (-0.4%), which occurs at 400 MeV/n energy and 3 T magnetic field. Considering the potential encounter of the studied materials in the clinical practice of MRgCT, in the form of phantoms, dosimeters, detectors, fiducial markers, radio-opaque clips, patient anatomies, etc., the results of this study highly contribute to assess the variation of WER values of the studied dosimetric materials and the changes in C-ion ranges within these materials when the transverse magnetic fields are applied to the materials subject to study.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Overview of Carbon-ion Radiotherapy
    Tsujii, Hirohiko
    [J]. MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777
  • [2] EVALUATION OF NEUTRON AMBIENT DOSE EQUIVALENT IN CARBON-ION RADIOTHERAPY WITH ENERGY SCANNING
    Matsumoto, Shinnosuke
    Yonai, Shunsuke
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 191 (03) : 310 - 318
  • [3] The Emerging Role of Carbon-Ion Radiotherapy
    Ebner, Daniel K.
    Kamada, Tadashi
    [J]. FRONTIERS IN ONCOLOGY, 2016, 6
  • [4] Carbon-ion radiotherapy for urological cancers
    Ishikawa, Hitoshi
    Hiroshima, Yuichi
    Kanematsu, Nobuyuki
    Inaniwa, Taku
    Shirai, Toshiyuki
    Imai, Reiko
    Suzuki, Hiroyoshi
    Akakura, Koichiro
    Wakatsuki, Masaru
    Ichikawa, Tomohiko
    Tsuji, Hiroshi
    [J]. INTERNATIONAL JOURNAL OF UROLOGY, 2022, 29 (10) : 1109 - 1119
  • [5] Recent innovations in carbon-ion radiotherapy
    Department of Accelerator and Medical Physics, Research Center for Particle Therapy, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage, Japan
    [J]. J. Rad. Res, 4 (385-392):
  • [6] Clinical advantages of carbon-ion radiotherapy
    Tsujii, Hirohiko
    Kamada, Tadashi
    Baba, Masayuki
    Tsuji, Hiroshi
    Kato, Hirotoshi
    Kato, Shingo
    Yamada, Shigeru
    Yasuda, Shigeo
    Yanagi, Takeshi
    Kato, Hiroyuki
    Hara, Ryusuke
    Yamamoto, Naotaka
    Mizoe, Junetsu
    [J]. NEW JOURNAL OF PHYSICS, 2008, 10
  • [7] Recent Innovations in Carbon-Ion Radiotherapy
    Minohara, Shinichi
    Fukuda, Shigekazu
    Kanematsu, Nobuyuki
    Takei, Yuka
    Furukawa, Takuji
    Inaniwa, Taku
    Matsufuji, Naruhiro
    Mori, Shinichiro
    Noda, Koji
    [J]. JOURNAL OF RADIATION RESEARCH, 2010, 51 (04) : 385 - 392
  • [8] Carbon-ion Radiotherapy for Colorectal Cancer
    Yamada, Shigeru
    Takiyama, Hirotoshi
    Isozaki, Yuka
    Shinoto, Makoto
    Makishima, Hirokazu
    Yamamoto, Naoyoshi
    Tsuji, Hiroshi
    [J]. JOURNAL OF THE ANUS RECTUM AND COLON, 2021, 5 (02): : 113 - 120
  • [9] The development of radiotherapy and carbon-ion radiotherapy for lung cancer
    Shirai, Katsuyuki
    Akahane, Keiko
    Wakatsuki, Masaru
    Tanaka, Osamu
    [J]. CANCER SCIENCE, 2018, 109 : 1214 - 1214
  • [10] Technical Note: Effect of magnetic fields on the microdosimetry of carbon-ion beams
    Dai, Tianyuan
    Li, Qiang
    Liu, Xinguo
    Dai, Zhongying
    He, Pengbo
    Ma, Yuanyuan
    Shen, Guosheng
    Chen, Weiqiang
    Zhang, Hui
    Meng, Qianqian
    Zhang, Xiaofang
    [J]. MEDICAL PHYSICS, 2019, 46 (08) : 3746 - 3750