Optical clock comparison for Lorentz symmetry testing

被引:176
|
作者
Sanner, Christian [1 ,6 ]
Huntemann, Nils [1 ]
Lange, Richard [1 ]
Tamm, Christian [1 ]
Peik, Ekkehard [1 ]
Safronova, Marianna S. [2 ,3 ,4 ]
Porsev, Sergey G. [2 ,5 ]
机构
[1] Phys Tech Bundesanstalt, Braunschweig, Germany
[2] Univ Delaware, Dept Phys & Astron, Newark, DE 19716 USA
[3] NIST, Joint Quantum Inst, College Pk, MD USA
[4] Univ Maryland, College Pk, MD 20742 USA
[5] Kurchatov Inst, Petersburg Nucl Phys Inst NRC, Gatchina, Russia
[6] JILA, Boulder, CO 80309 USA
基金
俄罗斯基础研究基金会;
关键词
INERTIAL MASS; ANISOTROPY;
D O I
10.1038/s41586-019-0972-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Questioning basic assumptions about the structure of space and time has greatly enhanced our understanding of nature. State-of-the-art atomic clocks(1-3) make it possible to precisely test fundamental symmetry properties of spacetime and search for physics beyond the standard model at low energies of just a few electronvolts(4). Modern tests of Einstein's theory of relativity try to measure so-far-undetected violations of Lorentz symmetry(5); accurately comparing the frequencies of optical clocks is a promising route to further improving such tests(6). Here we experimentally demonstrate agreement between two single-ion optical clocks at the 10(-18) level, directly validating their uncertainty budgets, over a six-month comparison period. The ytterbium ions of the two clocks are confined in separate ion traps with quantization axes aligned along non-parallel directions. Hypothetical Lorentz symmetry violations(5-7) would lead to periodic modulations of the frequency offset as the Earth rotates and orbits the Sun. From the absence of such modulations at the 10(-19) level we deduce stringent limits of the order of 10(-21) on Lorentz symmetry violation parameters for electrons, improving previous limits(8-10) by two orders of magnitude. Such levels of precision will be essential for low-energy tests of future quantum gravity theories describing dynamics at the Planck scale(4), which are expected to predict the magnitude of residual symmetry violations.
引用
收藏
页码:204 / +
页数:6
相关论文
共 50 条
  • [1] Optical clock comparison for Lorentz symmetry testing
    Christian Sanner
    Nils Huntemann
    Richard Lange
    Christian Tamm
    Ekkehard Peik
    Marianna S. Safronova
    Sergey G. Porsev
    [J]. Nature, 2019, 567 : 204 - 208
  • [2] Astrophysical Neutrinos in Testing Lorentz Symmetry
    Roberts, Agnes
    [J]. GALAXIES, 2021, 9 (03):
  • [3] Testing Lorentz symmetry with atoms and light
    Russell, Neil
    [J]. PHYSICA SCRIPTA, 2011, 84 (03)
  • [4] Clock-comparison tests of Lorentz and CPT symmetry in space -: art. no. 090801
    Bluhm, R
    Kostelecky, VA
    Lane, CD
    Russell, N
    [J]. PHYSICAL REVIEW LETTERS, 2002, 88 (09) : 908011 - 908014
  • [5] Atomic and optical tests of Lorentz symmetry
    Russell, Neil
    [J]. PHYSICA SCRIPTA, 2008, 78 (03)
  • [6] Testing Lorentz Symmetry with Lunar Laser Ranging
    Bourgoin, A.
    Hees, A.
    Bouquillon, S.
    Le Poncin-Lafitte, C.
    Francou, G.
    Angonin, M. -C.
    [J]. PHYSICAL REVIEW LETTERS, 2016, 117 (24)
  • [7] Testing Lorentz symmetry with planetary orbital dynamics
    Hees, A.
    Bailey, Q. G.
    Le Poncin-Lafitte, C.
    Bourgoin, A.
    Rivoldini, A.
    Lamine, B.
    Meynadier, F.
    Guerlin, C.
    Wolf, P.
    [J]. PHYSICAL REVIEW D, 2015, 92 (06):
  • [8] Prospects for testing Lorentz and CPT symmetry with antiprotons
    Vargas, Arnaldo J.
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2018, 376 (2116):
  • [9] Testing Lorentz Symmetry Using Chiral Perturbation Theory
    Noordmans, J. P.
    [J]. PROCEEDINGS OF THE SEVENTH MEETING ON CPT AND LORENTZ SYMMETRY, 2017, : 201 - 204
  • [10] Testing Lorentz symmetry violation with an invariant minimum speed
    Nassif, Claudio
    Amaro de Feria, A. C., Jr.
    dos Santos, Rodrigo Francisco
    [J]. MODERN PHYSICS LETTERS A, 2018, 33 (23)