DNA detection using a triple readout optical/AFM/MALDI planar microwell plastic chip

被引:14
|
作者
Ibanez, Alfredo J. [1 ]
Schueler, Thomas [2 ]
Moeller, Robert [2 ]
Fritzsche, Wolfgang [3 ]
Saluz, Hans-Peter [4 ]
Svatos, Ales [1 ]
机构
[1] Max Planck Inst Chem Ecol, Mass Spectrometry Res Grp, D-07745 Jena, Germany
[2] Univ Jena, Jenaer Biochip Initiat, Inst Phys Chem, D-07743 Jena, Germany
[3] Inst Photon Technol, D-07745 Jena, Germany
[4] Hans Knoell Inst, Leibniz Inst Nat Prod Res & Infect Biol, D-07745 Jena, Germany
关键词
D O I
10.1021/ac800426v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A ready-to-spot disposable DNA chip for specific and sensitive detection of DNA was developed. Plastic copolymeric substrate chemistry was optimized to selectively couple the target DNA with the active chip surface. At the same time, the developed substrate limits the unspecific adsorption of probe DNA molecules or additional polar contaminants in the test samples to the chip surface. The combination of glycidyl and n-butyl methacrylates was found to best fit the requirements of the assay. The fabricated DNA microarrays have mechanical properties similar to those of the glass or silicon substrates and, at the same time, provide chemically reactive surfaces that do not require lengthy chemical modification. An additional advantage of the plastic microchip is its compatibility with different analytical readout techniques, such as mass spectrometry (MALDI-TOF/MS), optical detection (fluorescence and enzyme-induced metal deposition), and imaging techniques (atomic force microscopy). These multiple readout techniques have given us the ability to compare the sensitivity, selectivity, and robustness of current state-of-the-art bioanalytical methods on the same platform exemplified by successful DNA-based detection of human cytomegalovirus. The obtained sensitivity for enzymatically enhanced silver deposition (10(-15) M) surpasses that of conventional fluorescence readouts. In addition, the assay's dynamic range (10(-6)-10(-15) M), reproducibility, and reliability of the DNA probe detection speaks for the silver deposition method. At compromised sensitivity (10(-9) M), the length of the DNA probes could be checked and, alternatively, DNA single point polymorphisms could be analyzed.
引用
收藏
页码:5892 / 5898
页数:7
相关论文
共 50 条
  • [1] Lab-on-a-chip optical detection system using plastic fiber optics
    McMullin, JN
    Qiao, H
    Goel, S
    McColman, SA
    Grundmann, A
    APPLICATIONS OF PHOTONIC TECHNOLOGY 6: CLOSING THE GAP BETWEEN THEORY, DEVELOPMENT, AND APPLICATION, 2003, 5260 : 114 - 118
  • [2] Microfluidic chip detection using MALDI mass spectrometry.
    Narcisse, DA
    Musyimi, HK
    Zhang, X
    Soper, SA
    Murray, KK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U233 - U234
  • [3] Single Escherichia coli bacteria detection using a chemiluminescence digital microwell array chip
    Wu, Wenshuai
    Nguyen, Binh Thi Thanh
    Liu, Patricia Yang
    Cai, Gaozhe
    Feng, Shilun
    Shi, Yuzhi
    Zhang, Boran
    Hong, Yuzhi
    Yu, Ruozhen
    Zhou, Xiaohong
    Liu, Ai Qun
    Zhang, Yi
    Yap, Eric Peng Huat
    Chin, Lip Ket
    BIOSENSORS & BIOELECTRONICS, 2022, 215
  • [4] A new DNA chip detection mechanism using optical pick-up actuators
    Kyung-Ho Kim
    Seung-Yop Lee
    Sookyung Kim
    Seung-Hwan Lee
    Seong-Gab Jeong
    Microsystem Technologies, 2007, 13 : 1359 - 1369
  • [5] A new DNA chip detection mechanism using optical pick-up actuators
    Kim, Kyung-Ho
    Lee, Seung-Yop
    Kim, Sookyung
    Lee, Seung-Hwan
    Jeong, Seong-Gab
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2007, 13 (8-10): : 1359 - 1369
  • [6] Optical detection of pathogens using protein chip
    Choi, Jeong-Woo
    Oh, Byung-Keun
    ADVANCED ENVIRONMENTAL MONITORING, 2008, : 348 - +
  • [7] Nondestructive readout of photochromic optical memory using photocurrent detection
    Tsujioka, T
    Hamada, Y
    Shibata, K
    Taniguchi, A
    Fuyuki, T
    APPLIED PHYSICS LETTERS, 2001, 78 (16) : 2282 - 2284
  • [8] The Degree of Hemagglutination on a Plastic Microfluidic Chip Using Impedimetric Detection
    Samae, Mandee
    Chirasatitsin, Somyot
    2019 12TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2019), 2019,
  • [9] MARINE PLASTIC DETECTION USING OPTICAL DATA
    Vitale, S.
    Ferraioli, G.
    Ali, M.
    Pascazio, V.
    Ricciotti, L.
    Roviello, G.
    Schirinzi, G.
    2022 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2022), 2022, : 2662 - 2665
  • [10] DNA Extraction Chip Using Key-type Planar Electrodes
    Azimi, S. M.
    Balachandran, W.
    Ahern, J.
    Slijepcevic, P.
    Newton, C.
    NSTI NANOTECH 2008, VOL 3, TECHNICAL PROCEEDINGS: MICROSYSTEMS, PHOTONICS, SENSORS, FLUIDICS, MODELING, AND SIMULATION, 2008, : 249 - +