Energy, indoor air quality, occupant behavior, self-reported symptoms and satisfaction in energy-efficient dwellings in Switzerland

被引:48
|
作者
Yang, Shen [1 ]
Pernot, Joelle Goyette [2 ]
Jorin, Corinne Hager [3 ]
Niculita-Hirzel, Helene [4 ]
Perret, Vincent [5 ]
Licina, Dusan [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Sch Architecture Civil & Environm Engn, Human Oriented Built Environm Lab, CH-1015 Lausanne, Switzerland
[2] HES SO Univ Appl Sci & Arts Western Switzerland, Sch Engn & Architecture Fribourg, Western Swiss Ctr Indoor Air Qual & Radon croqAIR, Transform Inst, CH-1700 Fribourg, Switzerland
[3] HES SO Univ Appl Sci & Arts Western Switzerland, Sch Engn & Architecture Fribourg, HumanTech Inst, CH-1700 Fribourg, Switzerland
[4] Univ Lausanne, Ctr Primary Care & Publ Hlth Unisante, Dept Hlth Work & Environm, CH-1066 Epalinges, Switzerland
[5] TOXpro SA, CH-1227 Carouge, Switzerland
关键词
Residences; Indoor air quality; Green certification; Energy renovation; Occupancy survey; RADON CONCENTRATIONS; GREEN; BUILDINGS; ENVIRONMENT; RETROFIT; HOUSES; CONSUMPTION; EXPOSURE; COMFORT; HOMES;
D O I
10.1016/j.buildenv.2019.106618
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
We performed the first large-scale investigation of indoor air quality (IAQ), energy and occupant behavior and satisfaction, in 650 energy-efficient dwellings in western Switzerland. The investigation included comparative assessment of 217 green-certified Minergie (M) and 433 energy-renovated (R) dwellings. Data were collected through a combination of questionnaire survey of building characteristics and occupancy symptoms/satisfaction, as well as field measurements of radon, total volatile organic compounds (TVOC), formaldehyde and fungi. The results showed that 90% of M dwellings relied on renewable and low-carbon energy sources for space and water heating, as compared to only 40% of R dwellings. The annual electricity consumptions of M and R dwellings were similar (similar to 33 kWh/m(2)), however, R dwellings consumed more gas and heating oil, thus contributing more to greenhouse gas emissions. Concentration of sampled air pollutants in the two dwelling types was generally below the maximum guideline values. Interestingly, concentration of all air pollutants was significantly lower in M relative to R dwellings: Radon (48 vs. 91 Bq/m(3)), TVOC (167 vs. 259 mu g/m(3)), formaldehyde (12 vs. 15 mu g/m(3)) and fungal colony forming units (33 vs. 48 CFUs). Statistical comparisons revealed that residents of naturally ventilated R dwellings tended to open window more frequently, while occupants of M dwellings relied on mechanical ventilation. We found no differences in occupant satisfaction and self-reported symptoms between the two dwelling types. The findings of this study are of potential utility for interpreting impacts of growing building energy renovation initiatives on indoor air quality, ventilation design and occupant satisfaction.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Methods for assessing indoor air quality, occupant comfort and energy consumption in energy-efficient dwellings
    Derbez, Mickael
    Berthineau, Bruno
    Cochet, Valerie
    Lethrosne, Murielle
    Pignon, Cecile
    Riberon, Jacques
    Kirchner, Severine
    [J]. ENVIRONNEMENT RISQUES & SANTE, 2012, 11 (01): : 40 - 51
  • [2] Indoor air quality in energy-efficient dwellings: Levels and sources of pollutants
    Derbez, M.
    Wyart, G.
    Le Ponner, E.
    Ramalho, O.
    Riberon, J.
    Mandin, C.
    [J]. INDOOR AIR, 2018, 28 (02) : 318 - 338
  • [3] Volatile organic compounds in 169 energy-efficient dwellings in Switzerland
    Yang, Shen
    Perret, Vincent
    Jorin, Corinne Hager
    Niculita-Hirzel, Helene
    Pernot, Joelle Goyette
    Licina, Dusan
    [J]. INDOOR AIR, 2020, 30 (03) : 481 - 491
  • [4] What are indoor air quality priorities for energy-efficient buildings?
    Wargocki, Pawel
    [J]. INDOOR AND BUILT ENVIRONMENT, 2015, 24 (05) : 579 - 582
  • [5] Effects of mechanical ventilation on indoor air quality and occupant health status in energy-efficient homes: A longitudinal field study
    Lim, Ah-Young
    Yoon, Miryoung
    Kim, Eun-Hye
    Kim, Hyun-Ah
    Lee, Myoung Ju
    Cheong, Hae-Kwan
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 785
  • [6] Weighting of indoor environment quality parameters for occupant satisfaction and energy efficiency
    Roumi, Soheil
    Zhang, Fan
    Stewart, Rodney A.
    Santamouris, Mattheos
    [J]. BUILDING AND ENVIRONMENT, 2023, 228
  • [7] Energy-efficient heat exchanger design for indoor air quality in intercity buses
    Atmaca, Ibrahim
    Demirezen, Aykut
    Caglar, Ahmet
    [J]. ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2021,
  • [8] INDOOR AIR QUALITY IN ENERGY EFFICIENT HOUSING
    Thatcher, T. L.
    [J]. JOURNAL OF GREEN BUILDING, 2006, 1 (02): : 32 - 38
  • [9] Indoor air quality and comfort in seven newly built, energy-efficient houses in France
    Mickael, Derbez
    Bruno, Berthineau
    Valerie, Cochet
    Murielle, Lethrosne
    Cecile, Pignon
    Jacques, Riberon
    Severine, Kirchner
    [J]. BUILDING AND ENVIRONMENT, 2014, 72 : 173 - 187
  • [10] Model Reduction for Indoor-Air Behavior in Control Design for Energy-Efficient Buildings
    Borggaard, Jeff
    Cliff, Eugene
    Gugercin, Serkan
    [J]. 2012 AMERICAN CONTROL CONFERENCE (ACC), 2012, : 2283 - 2288