Tunable diode laser absorption (TDL) and cavity ring-down spectroscopic (CRDS) sensors for atmospheric carbon dioxide were co-deployed during summer and fall of 2010 in field and laboratory conditions at Los Alamos National Laboratory. Both sensors were characterized for accuracy and precision for ambient carbon dioxide measurements at ground level and compared using both laboratory and ambient field data. After post-processing that included water vapor correction and calibration to WMO reference standards, overall mean [(CO2)-C-12-O-16] = 392.05 +/- 8.92 ppm and [(CO2)-C-12-O-16] = 392.22 +/- 9.05 ppm were observed between 29 July and 16 August 2010. The mean difference between the CRDS and TDL data for (CO2)-C-12 was 0.04 +/- 1.80 ppm (+/- 1 sigma in 60 s) for ambient field data, demonstrating the sensors meet the WMO/IAEA compatibility standard. The observations show over the 19-day period the [CO2](CRDS)'/[CO2](TDL) ratio exhibits a Gaussian distribution centered at x(0) = 1.003 +/- 3.38 x 10(-5) (+/- 1 sigma), indicating the ratio is dominated by random noise as opposed to a bias in the output of either sensor. The CRDS sensor is capable of measuring [(CO2)-C-12-O-16] to a precision of 23 ppb in 1 min and decreases to 6.5 ppb in 58 min. At one and 58-min, the TDL exhibits precisions of 29 ppb and 53 ppb. The CRDS is compact, fast, and stable; the TDL is larger and requires frequent calibrations to maintain its precision. The sensors also exhibit consistent hourly averaged diurnal values underscoring the interplay of biological, anthropogenic, and transport processes regulating CO2 at the site.
引用
下载
收藏
页码:991 / 997
页数:7
相关论文
共 5 条
  • [1] High-Accuracy and Fast-Response Flywheel Torque Control
    Zhou, Xinxiu
    Li, Meng
    Zhang, Ran
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2014, 2014
  • [2] A High-accuracy and Fast-response Synchrophasor Algorithm and Its Implementation for Distribution Network
    Wang Y.
    Lu C.
    Li Y.
    Xiong C.
    Fang C.
    Ling P.
    Dianwang Jishu/Power System Technology, 2019, 43 (03): : 753 - 760
  • [3] Inter-comparison of two air quality modelling systems for a case study in Berlin
    Suppan, P
    Skouloudis, AN
    INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2003, 20 (1-6) : 75 - 84
  • [4] A Fast-Response High-Accuracy Overvoltage Protection Circuit for Soft-Switching Current-Source Converters
    An, Zheng
    Mauger, Mickael J.
    Kandula, Rajendra Parasad
    Benzaquen, Joseph
    Divan, Deepak
    2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,
  • [5] In situ Raman spectroscopic investigation of flux-controlled crystal growth under high pressure: A case study of carbon dioxide hydrate growth in aqueous solution
    Ou, Wenjia
    Lu, Wanjun
    Qu, Kang
    Geng, Lantao
    Chou, I-Ming
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 101 : 834 - 843