A monitor for continuous and remote control of radon level and environmental parameters

被引:0
|
作者
Roca, V [1 ]
Boiano, A [1 ]
Esposito, A [1 ]
Guardato, S [1 ]
Pugliese, M [1 ]
Sabbarese, C [1 ]
Venoso, G [1 ]
机构
[1] Univ Naples Federico II, Dipartimento Sci Fisiche, I-80126 Naples, Italy
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
RaMonA (Radon Monitoring and Acquisition) is a compact device, developed by our laboratory, having the aim to perform the continuous monitoring of radon daughters collected on a silicon detector by an electrostatic field. In this paper the latest version of the system is presented, obtained after an updating process developed to rise these main objectives: the design of a new electronic project, the realisation of the complete integration of all function in a single module, the installation on board of a microprocessor hosting the software necessary to run the system and the substitution of the serial port with an Ethernet interface, allowing so the driving of the station from any point of the net. The prototype of this new RaMonA has been successfully tested and many stations are actually under construction to be installed in a series of schools to realise a network for the radon monitoring in the soil.
引用
收藏
页码:1563 / 1566
页数:4
相关论文
共 50 条
  • [1] A CONTINUOUS MONITOR FOR THE MEASUREMENT OF ENVIRONMENTAL RADON
    CHITTAPORN, P
    EISENBUD, M
    HARLEY, NH
    HEALTH PHYSICS, 1981, 41 (02): : 405 - 410
  • [2] CONTINUOUS RADON MONITOR
    THOMAS, JW
    COUNTESS, RJ
    HEALTH PHYSICS, 1979, 36 (06): : 734 - 738
  • [3] DESIGN OF A CONTINUOUS DIGITAL-OUTPUT ENVIRONMENTAL RADON MONITOR
    WRENN, ME
    SPITZ, H
    COHEN, N
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (01) : 645 - 648
  • [4] The influence of environmental parameters in electrostatic cell radon monitor response
    Roca, V
    De Felice, P
    Esposito, AM
    Pugliese, M
    Sabbarese, C
    Vaupotich, J
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (2-3) : 243 - 247
  • [5] Development of a radon progeny continuous monitor
    Liu, Liang-Jun
    Xiao, De-Tao
    Lei, Jia-Rong
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2007, 41 (04): : 509 - 512
  • [6] IMPROVEMENTS TO THE PASSIVE ENVIRONMENTAL RADON MONITOR
    HAGEE, GR
    JENKINS, PH
    JARVIS, JY
    HEALTH PHYSICS, 1984, 47 (01): : 203 - 203
  • [7] CONTINUOUS MONITOR FOR RADON IN GROUND-WATER
    CATHEY, L
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (10): : 1252 - 1252
  • [8] EVALUATION OF CHARACTERISTICS OF THE PASSIVE ENVIRONMENTAL RADON MONITOR
    HAGEE, GR
    JENKINS, PH
    GEPHART, PJ
    JARVIS, JY
    HOPPER, RD
    HEALTH PHYSICS, 1985, 49 (01): : 156 - 157
  • [9] PASSIVE INTEGRATING RADON MONITOR FOR ENVIRONMENTAL MONITORING
    ALTER, HW
    FLEISCHER, RL
    HEALTH PHYSICS, 1981, 40 (05): : 693 - 702
  • [10] Novel panorama megasize environmental radon monitor
    Sohrabi, M.
    Ghahremani, M.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 181