Magnetic field measurement system in vertical status for superconducting undulator cooled in Dewar

被引:5
|
作者
Chen, Zilin [1 ,2 ]
He, Ping [1 ]
Li, Yuhui [1 ]
Yang, Xiangchen [1 ]
Wei, Junhao [1 ,3 ]
Zhang, Xiangzhen [1 ,2 ]
Bian, Xiaojuan [1 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, 19B Yuquan Rd, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, 19A Yuquan Rd, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Inst High Energy Phys, China Spallat Neutron Source, 1 Zhongziyuan Rd, Dongguan 523000, Guangdong, Peoples R China
关键词
Acceleration cavities and superconducting magnets (high-temperature superconductor; radiation hardened magnets; nor mal-conducting; permanent magnet devices; wigglers and undulators); Accelerator Subsystems and Technologies; Instrumentation for particle accelerators and storage rings- high energy (linear accelerators; synchrotrons); Instrumentation for synchrotron radiation accelerators;
D O I
10.1088/1748-0221/17/09/T09008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Superconducting undulators (SCUs) for advanced light sources are being developed rapidly to emit light with higher brightness and flux. The SCU consists of two superconducting magnets with a small gap, each with alternating poles. The SCU is invisible when operating in a Dewar or cryostat, so measuring the magnetic field in the narrow magnetic gap is a challenge in the development of the SCU. This paper presents a measurement system in vertical status for scanning the magnetic field of the SCU along the z-axis. The SCU is immersed vertically in 4.2 K liquid helium in a Dewar and the scanning is powered by a servo motor at room temperature. The measurement system overcomes the temperature difference of 300 K to drive the Hall probes to scan the magnetic field in the narrow magnetic gap of the SCU. In order to make the scanning area of the Hall probes coincide with the trajectory of the electron beam, a lot of detailed work on mechanical aspects has been done, such as controlling the positional accuracy of the Hall probes as they move, high precision machining and limiting the direction of movement. Unlike the currently reported magnetic field scans in the vertical status which are only available for SCU mock-ups of few periods, this system supports magnetic field measurements for SCUs up to 1.5 m long. The measurement system was validated on a 20-period SCU prototype, and after modification, the magnetic field of a liquid helium-cooled 30.5-period SCU was scanned. When the excitation current of the SCU with a magnetic gap of 7 mm is 450 A, the system measured a field distribution with a peak magnetic field of 1 T. The measurement system completed a full stroke trial run of 1750 mm before the 1.5 m SCU was machined. The results of magnetic field measurement from scanning in vertical status can be used as a reference for local shimming and correction of the magnetic poles of the SCU. This work establishes the SCU's ability to operate in cryostat horizontally.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Magnetic measurement system for the NSLS superconducting undulator vertical test facility
    Harder, D
    Chouhan, S
    Lehecka, M
    Rakowsky, G
    Skaritka, J
    Tanabe, T
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 1063 - 1065
  • [2] The Magnetic Field Measurement Systems for a Cryogenic Undulator and a Superconducting Undulator at SSRF
    Wang, H. F.
    Zhang, J. M.
    Qian, M. F.
    Zhang, W.
    Ding, Yi.
    Zhou, Q. G.
    9TH INTERNATIONAL PARTICLE ACCELERATOR CONFERENCE (IPAC18), 2018, 1067
  • [3] Vertical measurement and on-line correction of the magnetic field for a 1.5-m-long superconducting undulator
    Chen, Zilin
    Yang, Xiangchen
    Wei, Junhao
    Zhang, Xiangzhen
    Bian, Xiaojuan
    Li, Yuhui
    He, Ping
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1047
  • [4] The Online Undulator Magnetic Field Measurement System
    Hu, Jiaying
    Yang, Jie
    Yu, Cheng
    Zhu, Ya
    Zhang, Wei
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (05) : 1 - 5
  • [5] A review of magnetic field measurements of full scale conduction cooled superconducting undulator coils
    Casalbuoni, Sara
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2019, 32 (02):
  • [6] Magnetic field measurement and optimization method of a small gap superconducting undulator
    Chen, Jinya
    Zhang, Jidong
    Wu, Zezhou
    Zhou, Qiaogen
    He Jishu/Nuclear Techniques, 2024, 47 (12):
  • [7] Helium-Free Field Measurement System for Superconducting Undulator Coils
    Grau, Andreas
    Mashkina, Elena
    Bernhard, Axel
    Casalbuoni, Sara
    Peiffer, Peter
    Wollmann, Daniel
    Rossmanith, Robert
    Hagelstein, Michael
    Steffens, Erhard
    Baumbach, Tilo
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) : 2333 - 2336
  • [8] Positional calibration of Hall probes for magnetic field measurement of a superconducting undulator in SHINE
    Wu Z.
    Zhang J.
    Chen J.
    Zhou Q.
    He Jishu/Nuclear Techniques, 2023, 46 (09):
  • [9] Magnetic-Field Shimming and Field Measurement Issue of the 130-Pole Superconducting Undulator
    Jan, J. C.
    Hwang, C. S.
    Wu, C. M.
    Lin, F. Y.
    Chang, C. H.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 1705 - 1708
  • [10] Magnetic Field Measurements of Full-Scale Conduction-Cooled Superconducting-Undulator-Coils
    Casalbuoni, Sara
    Glamann, Nicole
    Grau, Andreas
    Holubek, Tomas
    de Jauregui, David Saez
    Boffo, Cristian
    Gerhard, Thomas
    Turenne, Melanie
    Walter, Wolfgang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (03)