Measurement consistency and three-dimensional electromechanical anthropometry

被引:20
|
作者
Feathers, DJ [1 ]
Paquet, VL [1 ]
Drury, CG [1 ]
机构
[1] SUNY Buffalo, Sch Engn & Appl Sci, Dept Ind Engn, Buffalo, NY 14260 USA
关键词
anthropometry; electromechanical measurements; reliability; wheelchair users;
D O I
10.1016/j.ergon.2003.08.001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Two pilot studies investigated potential sources of error in static human body surface measurement for conventional anthropometry methods and three-dimensional electromechanical methods under different experimental conditions. In the first pilot study, two anthropometrists measured Humeral breadth, Radiale-Stylion length and Wrist breadth of a cadaveric arm repeatedly in nearly nude and lightly clothed conditions with conventional and electromechanical approaches in two separate, repeated measurement sessions. Analysis of variance (ANOVA) performed on these measurements demonstrated significant differences across measurers, methods, the interaction between measurer and clothing, and the interaction between measurer and methods, suggesting systematic error contributions for these variables. ANOVA performed on the standard deviation of data for each anthropometric dimension showed differences across methods and clothing conditions, demonstrating differences in measurement consistency for these variables. In the second pilot study, measurement consistency was evaluated for the conventional and electromechanical methods for anthropometric measurements of ten wheelchair users who were clothed and not capable of maintaining erect seated postures for the measurement session. The measurement consistencies for repeated measurements of acromion height, biacromial breadth, eye height, knee height and waist depth obtained with each method were compared to established standards. ANOVA showed differences between methods and measurers for some of the anthropometric dimensions, although the magnitude of the differences was relatively small. Relatively low variability in measurements within method for each dimension within condition was found in both studies. This suggests that conventional dimensions recorded with three-dimensional electromechanical approaches can be measured consistently, at least for the anthropometric dimensions and experimental conditions considered in these studies.
引用
收藏
页码:181 / 190
页数:10
相关论文
共 50 条
  • [1] CT Based Three-Dimensional Measurement of Orbit and Eye Anthropometry
    Weaver, Ashley A.
    Loftis, Kathryn L.
    Tan, Josh C.
    Duma, Stefan M.
    Stitzel, Joel D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (10) : 4892 - 4897
  • [2] Challenges in the Application of Three-dimensional Anthropometry
    Niu, Jianwei
    Zhang, Yijing
    Wu, Jiang
    ICIEA: 2009 4TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-6, 2009, : 855 - +
  • [3] Three-dimensional anthropometry: reliability and error.
    Feathers, D
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2002, : 69 - 69
  • [4] Three-dimensional nanosprings for electromechanical sensors
    Bell, DJ
    Sun, Y
    Zhang, L
    Dong, LX
    Nelson, BJ
    Grützmacher, D
    Transducers '05, Digest of Technical Papers, Vols 1 and 2, 2005, : 15 - 18
  • [5] Three-dimensional nanosprings for electromechanical sensors
    Bell, D. J.
    Sun, Y.
    Zhang, L.
    Dong, L. X.
    Nelson, B. J.
    Gruetzmacher, D.
    SENSORS AND ACTUATORS A-PHYSICAL, 2006, 130 (54-61) : 54 - 61
  • [6] Three-dimensional surface anthropometry: Applications to the human body
    Jones, PRM
    Rioux, M
    OPTICS AND LASERS IN ENGINEERING, 1997, 28 (02) : 89 - 117
  • [7] Reliability of periocular anthropometry using three-dimensional digital stereophotogrammetry
    Yongwei Guo
    Alexander C. Rokohl
    Friederike Schaub
    Xiaoyi Hou
    Jinhua Liu
    Yue Ruan
    Renbing Jia
    Konrad R. Koch
    Ludwig M. Heindl
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 2517 - 2531
  • [8] Preliminary evaluation of an electromagnetic three-dimensional digitizer in facial anthropometry
    Ferrario, VF
    Sforza, C
    Poggio, CE
    Cova, M
    Tartaglia, G
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 1998, 35 (01): : 9 - 15
  • [9] Reliability of periocular anthropometry using three-dimensional digital stereophotogrammetry
    Guo, Yongwei
    Rokohl, Alexander C.
    Schaub, Friederike
    Hou, Xiaoyi
    Liu, Jinhua
    Ruan, Yue
    Jia, Renbing
    Koch, Konrad R.
    Heindl, Ludwig M.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (11) : 2517 - 2531
  • [10] Comparison of three-dimensional reconstruction approaches for anthropometry in apparel design
    Zhao, Yu
    Mo, Yu
    Sun, Mengqin
    Zhu, Yi
    Yang, Cong
    JOURNAL OF THE TEXTILE INSTITUTE, 2019, 110 (11) : 1635 - 1643