Speech Perception Comparisons Using an Implanted and an External Microphone in Existing Cochlear Implant Users

被引:6
|
作者
Jenkins, Herman A. [1 ]
Uhler, Kristin [1 ]
机构
[1] Univ Colorado, Sch Med, Dept Otolaryngol, Aurora, CO 80045 USA
关键词
Cochlear implant; Implanted microphone; Percutaneous plug; Speech perception;
D O I
10.1097/MAO.0b013e31823c9335
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To compare the speech understanding abilities of cochlear implant listeners using 2 microphone technologies, the Otologics fully implantable Carina and the Cochlear Freedom microphones. Study Design: Feasibility study using direct comparison of the 2 microphones, nonrandomized and nonblinded within case studies. Setting: Tertiary referral center hospital outpatient clinic. Patients: Four subjects with greater than 1 year of unilateral listening experience with the Freedom Cochlear Implant and a CNC word score higher than 40%. Intervention: A Carina microphone coupled to a percutaneous plug was implanted on the ipsilateral side of the cochlear implant. Two months were allowed for healing before connecting to the Carina microphone. The percutaneous plug was connected to a body worn external processor with output leads inserted into the auxiliary port of the Freedom processor. Subjects were instructed to use each of the 2 microphones for half of their daily implant use. Main Outcome Measures: Aided pure tone thresholds, consonant-nucleus-consonant (CNC), Bamford-Kowel-Bench Speech in Noise test (BKN-SIN), and Abbreviated Profile of Hearing Aid Benefit. Results: All subjects had sound perceptions using both microphones. The loudness and quality of the sound was judged to be poorer with the Carina in the first 2 subjects. The latter 2 demonstrated essential equivalence in the second two listeners, with the exception of the Abbreviated Profile of Hearing Aid Benefit reporting greater percentage of problems for the Carina in the background noise situation for subject 0011-003PP. CNC word scores were better with the Freedom than the Carina in all 4 subjects. The latter 2 showed improved speech perception abilities with the Carina, compared with the first 2. The BKB-SIN showed consistently better results with the Freedom in noise. Conclusion: Early observations indicate that it is potentially feasible to use the fully implanted Carina microphone with the Freedom Cochlear Implant. The authors would anticipate that outcomes would improve as more knowledge is gained in signal processing and with the fabrication of an integrated device.
引用
收藏
页码:13 / 19
页数:7
相关论文
共 50 条
  • [1] Impact of Microphone Configuration on Speech Perception of Cochlear Implant Users in Traffic Noise
    Weissgerber, Tobias
    Bandeira, Mariana
    Brendel, Martina
    Stoever, Timo
    Baumann, Uwe
    [J]. OTOLOGY & NEUROTOLOGY, 2019, 40 (03) : E198 - E205
  • [2] Speech perception in noise and sound localization using different microphone modes in pediatric bilateral cochlear implant users
    Mueller, Verena
    Krause, Jasmin
    Klunter, Heinz Dieter
    Streicher, Barbara
    Lang-Roth, Ruth
    [J]. INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2022, 156
  • [3] Perception of Sung Speech in Bimodal Cochlear Implant Users
    Crew, Joseph D.
    Galvin, John J., III
    Fu, Qian-Jie
    [J]. TRENDS IN HEARING, 2016, 20
  • [4] Cochlear Blood Flow and Speech Perception Ability in Cochlear Implant Users
    Nakashima, Tsutomu
    Hattori, Taku
    Sone, Michihiko
    Asahi, Kiyomitsu
    Matsuda, Naoko
    Teranishi, Masaaki
    Yoshida, Tadao
    Kato, Ken
    Sato, Eisuke
    [J]. OTOLOGY & NEUROTOLOGY, 2012, 33 (02) : 165 - 168
  • [5] Contribution of speech rate to speech perception in multichannel cochlear implant users
    Iwasaki, S
    Nagura, M
    Ocho, S
    Hoshino, T
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2002, 111 (08): : 718 - 721
  • [6] Feasibility of an implanted microphone for cochlear implant listening
    Gerard, Jean-Marc
    Demanez, Laurent
    Salmon, Caroline
    Vanpoucke, Filiep
    Walraevens, Joris
    Plasmans, Anke
    De Siati, Daniele
    Lefebvre, Philippe
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (03) : 1383 - 1390
  • [7] Frequency change detection and speech perception in cochlear implant users
    Zhang, Fawen
    Underwood, Gabrielle
    McGuire, Kelli
    Liang, Chun
    Moore, David R.
    Fu, Qian-Jie
    [J]. HEARING RESEARCH, 2019, 379 : 12 - 20
  • [8] Longitudinal Infant Speech Perception in Young Cochlear Implant Users
    Uhler, Kristin
    Yoshinaga-Itano, Christie
    Gabbard, Sandra Abbott
    Rothpletz, Ann M.
    Jenkins, Herman
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2011, 22 (03) : 129 - 142
  • [9] Auditory cortical activation and speech perception in cochlear implant users
    Green, K. M. J.
    Julyan, P. J.
    Hastings, D. L.
    Ramsden, R. T.
    [J]. JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2008, 122 (03): : 238 - 245
  • [10] Feasibility of an implanted microphone for cochlear implant listening
    Jean-Marc Gérard
    Laurent Demanez
    Caroline Salmon
    Filiep Vanpoucke
    Joris Walraevens
    Anke Plasmans
    Daniele De Siati
    Philippe Lefèbvre
    [J]. European Archives of Oto-Rhino-Laryngology, 2017, 274 : 1383 - 1390