Repeatability and reproducibility of ultrasonographic measurement of carotid intima thickness

被引:7
|
作者
Lau, Kar-Ho [1 ]
Fung, Ying-Keung [1 ]
Cheung, Yuk-Ting [1 ]
Tsang, Wing-Keung [1 ]
Ying, Michael [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Kowloon, Hong Kong, Peoples R China
关键词
ultrasound; carotid artery; intima thickness; repeatability; reproducibility; MEDIA THICKNESS; ARTERIAL-WALL; ULTRASOUND; ATHEROSCLEROSIS;
D O I
10.1002/jcu.20906
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose. To evaluate the repeatability and reproducibility of intima thickness (IT) measurements at different sites along the common carotid artery and compare with intimamedia thickness (IMT) measurements. Methods. Ultrasound examinations of common carotid artery were performed in 30 healthy subjects and 20 patients with diabetes mellitus. Carotid IT and IMT were measured at 10 mm, 13 mm, and 16 mm upstream from the carotid bulb. Each subject was scanned by three operators to evaluate inter-operator reproducibility. Each operator scanned the subjects twice to evaluate intra-operator repeatability. Inter-equipment reproducibility of the measurements was evaluated. Results. The inter-operator reproducibility for measuring carotid IT at the three sites was 81.5%, 81.9% and 69.1%, respectively, slightly lower than carotid IMT measurement (89.7%, 86.5%, 75.2%, respectively). The intra-operator repeatability for carotid IT measurement at the three sites ranged 76.9-89.5%, 67.4-90.3%, and 55.2-70.5%, respectively, and was lower than for IMT measurement (86.5-96.9%, 87.6-95.7%, 79.9-86.5%, respectively). The inter-equipment reproducibility of IMT (75.7-86.6%) was slightly better than for IT measurement (71.4-75.9%). Conclusions. Ultrasonographic measurement of carotid IT is repeatable and reproducible, although not as good as IMT. Measurements preformed 10 mm to 13 mm upstream from the carotid bulb yield more repeatable and reproducible results. (C) 2011 Wiley Periodicals, Inc. J Clin Ultrasound 40: 79-84, 2012; Published online in Wiley Online Library (wileyonlinelibrary.com). DOI: 10.1002/jcu.20906
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [1] Reproducibility and repeatability of intima-media thickness measurement employing dedicated software
    Bieniaszewski, L
    Kunicka, K
    Swiatek, H
    Oziminski, T
    Nalezinski, S
    Swierblewska, E
    Kruszewski, P
    Neubauer-Geryk, J
    Wyrzykowski, B
    [J]. JOURNAL OF HYPERTENSION, 2005, 23 : S349 - S349
  • [2] Prognostic value of ultrasonographic measurement of carotid intima media thickness in dialysis patients
    Benedetto, FA
    Mallamaci, F
    Tripepi, G
    Zoccali, C
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2001, 12 (11): : 2458 - 2464
  • [3] Measurement of carotid artery intima-media thickness.: Analysis of reproducibility
    Baguet, JP
    Moreau-Gaudry, A
    Siché, JP
    Tremel, F
    Cinquin, P
    Mallion, JM
    [J]. ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2000, 93 (09): : 1139 - 1144
  • [4] Reproducibility of Sonographic Measurements of Carotid Intima-Media Thickness
    Velazquez, F.
    Berna, J. D.
    Abellan, J. L.
    Serrano, L.
    Escribano, A.
    Canteras, M.
    [J]. ACTA RADIOLOGICA, 2008, 49 (10) : 1162 - 1166
  • [5] The repeatability and reproducibility of gingival thickness measurement with an ultrasonic device
    Furtak, Aneta
    Leszczynska, Elzbieta
    Sender-Janeczek, Aleksandra
    Bednarz, Wojciech
    [J]. DENTAL AND MEDICAL PROBLEMS, 2018, 55 (03) : 281 - 288
  • [6] Measurement of carotid intima media thickness in children
    Gurbuz, Defne
    Ozel, Deniz
    Ozel, Betul Duran
    Ozkan, Fuat
    [J]. JOURNAL OF PEDIATRICS, 2016, 170 : 346 - 346
  • [7] Reproducibility of ultrasonographic measurements of different carotid and femoral artery segments in healthy subjects and in patients with increased intima media thickness
    Smilde, TJ
    Wollersheim, H
    VanLangen, H
    Stalenhoef, AFH
    [J]. CLINICAL SCIENCE, 1997, 93 (04): : 317 - 324
  • [8] Individual measurement and significance of carotid intima, media, and intima-media thickness by B-mode ultrasonographic image processing
    Bae, Jang-Ho
    Kim, Wuon-Shik
    Rihal, Charanjit S.
    Lerman, Amir
    [J]. ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2006, 26 (10) : 2380 - 2385
  • [9] Ultrasonographic Measurement of Intima-Media Thickness of the Carotid Artery Before Coronary Artery Bypass Grafting
    Yoshiharu Nishimura
    Yoshitaka Okamura
    Keiichi Fujiwara
    Hiroyoshi Sekii
    Shuji Yamamoto
    Atsutoshi Hatada
    Takahiro Hisaoka
    [J]. Surgery Today, 2005, 35 : 28 - 30
  • [10] Ultrasonographic measurement of intima-media thickness of the carotid artery before coronary artery bypass grafting
    Nishimura, Y
    Okamura, Y
    Fujiwara, K
    Sekii, H
    Yamamoto, S
    Hatada, A
    Hisaoka, T
    [J]. SURGERY TODAY, 2005, 35 (01) : 28 - 30