Magnetic Resonance Cholangiography in Living Donor Liver Transplantation

被引:20
|
作者
Hsu, Hsien-Wen [1 ,2 ]
Tsang, Leo Leung-Chit [1 ,2 ]
Yap, Anthony [3 ,4 ]
Huang, Tung-Liang [1 ,2 ]
Chen, Tai-Yi [1 ,2 ]
Lin, Tsan-Shiun [3 ,4 ]
Concejero, Allan M. [3 ,4 ]
Ou, Shin-You [1 ,2 ]
Yu, Chun-Yen [1 ,2 ]
Chen, Chao-Long [3 ,4 ]
Cheng, Yu-Fan [1 ,2 ]
机构
[1] Chang Gung Mem Hosp, Kaohsiung Med Ctr, Dept Diagnost Radiol, Kaohsiung 83305, Taiwan
[2] Chang Gung Univ, Coll Med, Kaohsiung 83305, Taiwan
[3] Chang Gung Mem Hosp, Kaohsiung Med Ctr, Dept Surg, Kaohsiung 83305, Taiwan
[4] Chang Gung Univ, Coll Med, Kaohsiung, Taiwan
关键词
Magnetic resonance cholangiography; Intraoperative cholangiography; Living donor liver transplantation; INTRAHEPATIC BILE-DUCTS; BILIARY ANATOMY; PREOPERATIVE EVALUATION; CT CHOLANGIOGRAPHY; IMAGING MODALITY; CHOLANGIOPANCREATOGRAPHY; ABNORMALITIES; COMPLICATIONS;
D O I
10.1097/TP.0b013e31821c1e33
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Objective. Exact knowledge of biliary anatomy is essential in living donor liver transplantation. The purpose of this study was to evaluate the accuracy of pretransplant magnetic resonance cholangiography (MRC) in depicting the biliary anatomy in comparison with intraoperative cholangiography (IOC). Materials and Methods. From May 2006 to July 2009, 451 potential living liver donors underwent pretransplant evaluation at the Chang Gung Memorial Hospital-Kaohsiung Medical Center. Two hundred thirty-three donors underwent donor hepatectomy. Of these, only 203 donors with both preoperative MRC and IOC were included in this study. Results. Of the 451 potential donors, 218 (48.3%) were considered unsuitable for liver donation, hence was immediately disqualified after the initial evaluation for various reasons. Six of the 218 unsuitable donors (2.8%) were excluded due to complicated biliary anatomy. The overall accuracy rate of MRC for defining the biliary anatomy was 91.6%, with 84.9% sensitivity, 96% specificity, 88.2% positive predictive value, and 94.7% negative predictive value. There were 14 misidentified cases. The errors in MRC reading was largely attributed to the poor contrast between the biliary ducts and the surrounding tissues and organs. The concurrence between MRC and IOC were commendable (kappa=0.9). No significant biliary complications were noted in the mismatch group. Conclusion. MRC is essential for all pretransplantation evaluation with 91.6% accuracy rate.
引用
收藏
页码:94 / 99
页数:6
相关论文
共 50 条
  • [1] Magnetic Resonance Cholangiography in Living Donor Liver Transplantation
    Hsu, Hsien-Wen
    Cheng, Yu-Fan
    Chen, Chao-Long
    Tsang, Leung-Chit
    LIVER TRANSPLANTATION, 2010, 16 (06) : S108 - S108
  • [2] Clinical Efficacy of Pretransplant Magnetic Resonance Cholangiography of Donor for Living Donor Liver Transplantation
    Gyu-seong, Choi
    HyungChul, Kim
    JunChul, Jung
    Juik, Moon
    LIVER TRANSPLANTATION, 2011, 17 (06) : S271 - S271
  • [3] The Role of Magnetic Resonance Cholangiography for Recipients after Living Donor Liver Transplantation
    Hsu, Hsien-Wen
    Tsang, Leung-Chit Leo
    Chen, Chao-Long
    Cheng, Yu-Fan
    LIVER TRANSPLANTATION, 2011, 17 (06) : S112 - S112
  • [4] Stratifying risk of biliary complications in adult living donor liver transplantation by magnetic resonance cholangiography
    Kashyap, Randeep
    Bozorgzadeh, Adel
    Abt, Peter
    Tsoulfas, Georgios
    Maloo, Manoj
    Sharma, Rajeev
    Patel, Siddharth
    Dombroski, David
    Mantry, Parvez
    Safadjou, Saman
    Jain, Ashok
    Orloff, Mark
    TRANSPLANTATION, 2008, 85 (11) : 1569 - 1572
  • [5] Preoperative evaluation of biliary anatomy of donor in living donor liver transplantation by conventional nonenhanced magnetic resonance cholangiography
    Song, Gi-Won
    Lee, Sung-Gyu
    Hwang, Shin
    Sung, Gyu-Bo
    Park, Kwang-Min
    Kim, Ki-Hun
    Ahn, Chul-Soo
    Moon, Deok-Bog
    Ha, Tae-Yong
    Kim, Bum-Soo
    Moon, Ki-Myung
    Jung, Dong-Hwan
    TRANSPLANT INTERNATIONAL, 2007, 20 (02) : 167 - 173
  • [6] Role of multislice CT and magnetic resonance cholangiography in preoperative evaluation of potential donor in living related liver transplantation
    Abdel-Rahman, Hossam M.
    Enaba, Moanes M.
    Hasan, Doaa I.
    Tantawy, Fathy A.
    Morsy, Mansour M.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2016, 47 (01): : 33 - 42
  • [7] Magnetic Resonance Cholangiography in Living Donor Liver Transplantation: Comparison of Preenhanced and Post-Gadolinium-Enhanced Methods
    Chiang, H-J.
    Hsu, H-W.
    Chen, P-C.
    Chiang, H-W.
    Huang, T-L.
    Chen, T-Y.
    Chen, C-L.
    Cheng, Y-F.
    TRANSPLANTATION PROCEEDINGS, 2012, 44 (02) : 324 - 327
  • [8] Magnetic Resonance Spectroscopy in Living-Donor Liver Transplantation
    Chiang, H. -J.
    Chang, W. -P.
    Chiang, H. -W.
    Lazo, M. Z.
    Chen, T. -Y.
    Ou, H. -Y.
    Tsang, L. L. -C.
    Huang, T. -L.
    Chen, C. -L.
    Cheng, Y. -F.
    TRANSPLANTATION PROCEEDINGS, 2016, 48 (04) : 1003 - 1006
  • [9] Magnetic Resonance Fat Quantification in Living Donor Liver Transplantation
    Chiang, H. -J.
    Lin, L. -H.
    Li, C. -W.
    Lin, C. -C.
    Chiang, H. -W.
    Huang, T. -L.
    Chen, C. -L.
    Cheng, Y. -F.
    TRANSPLANTATION PROCEEDINGS, 2014, 46 (03) : 666 - 668
  • [10] 3.0T Magnetic Resonance Cholangiography in Evaluation of the Binary Anatomy of Donors in Living Donor Liver Transplantation (LDLT)
    Fawzi, Mohamed
    AbdelBary, Mohamed Salah
    Ali, Mohamed Hassan
    Tawab, Mohamed Abdel
    Aziz, Omar Abdel
    LIVER TRANSPLANTATION, 2010, 16 (06) : S108 - S109