Dose-volume based ranking of incident beam direction and its utility in facilitating IMRT beam placement

被引:27
|
作者
Schreibmann, E [1 ]
Xing, L [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
intensity-modulated radiation therapy; inverse planning; dose optimization; beam orientation;
D O I
10.1016/j.ijrobp.2005.06.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Beam orientation optimization in intensity-modulated radiation therapy (IMRT) is computationally intensive, and various single beam ranking techniques have been proposed to reduce the search space. Up to this point, none of the existing ranking techniques considers the clinically important dose-volume effects of the involved structures, which may lead to clinically irrelevant angular ranking. The purpose of this work is to develop a clinically sensible angular ranking model with incorporation of dose-volume effects and to show its utility for IMRT beam placement. Methods and Materials: The general consideration in constructing this angular ranking function is that a beamlet/beam is preferable if it can deliver a higher dose to the target without exceeding the tolerance of the sensitive structures located on the path of the beamlet/beam. In the previously proposed dose-based approach, the beamlets; are treated independently and, to compute the maximally deliverable dose to the target volume, the intensity of each beamlet is pushed to its maximum intensity without considering the values of other beamlets. When volumetric structures are involved, the complication arises from the fact that there are numerous dose distributions corresponding to the same dose-volume tolerance. In this situation, the beamlets; are not independent and an optimization algorithm is required to find the intensity profile that delivers the maximum target dose while satisfying the volumetric constraints. In this study, the behavior of a volumetric organ was modeled by using the equivalent uniform dose (EUD). A constrained sequential quadratic programming algorithm (CFSQP) was used to find the beam profile that delivers the maximum dose to the target volume without violating the EUD constraint or constraints. To assess the utility of the proposed technique, we planned a head-and-neck and abdominal case with and without the guidance of the angular ranking information. The qualities of the two types of IMRT plans were compared quantitatively. Results: An effective angular ranking model with consideration of volumetric effect has been developed. It is shown that the previously reported dose-based angular ranking represents a special case of the general formalism proposed here. Application of the technique to a abdominal and a head-and-neck IMRT case indicated that the proposed technique is capable of producing clinically sensible angular ranking. In both cases, we found that the IMRT plans obtained under the guidance of EUD-based angular ranking were improved in comparison with that obtained using the conventional uniformly spaced beams. Conclusions: The EUD-based function is a general approach for angular ranking and allows us to identify the potentially good and bad angles for clinically complicated cases. The ranking can be used either as a guidance to facilitate the manual beam placement or as prior information to speed up the computer search for the optimal beam configuration. Thus the proposed technique should have positive clinical impact in facilitating the IMRT planning process. (c) 2005 Elsevier Inc.
引用
收藏
页码:584 / 593
页数:10
相关论文
共 50 条
  • [1] Dose-volume based ranking of incident beams and its utility in facilitating IMRT beam placement
    Hai, JO
    Schreibmann, E
    Xing, L
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S637 - S638
  • [2] Incorporating dose-volume effect into the ranking of beam orientations
    Schreibmann, E
    Xing, L
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1896 - 1896
  • [3] Real-time beam monitoring for error detection in IMRT plans and impact on dose-volume histograms
    Marrazzo, Livia
    Arilli, Chiara
    Pasler, Marlies
    Kusters, Martijn
    Canters, Richard
    Fedeli, Luca
    Calusi, Silvia
    Casati, Marta
    Talamonti, Cinzia
    Simontacchi, Gabriele
    Livi, Lorenzo
    Pallotta, Stefania
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (03) : 243 - 254
  • [4] OPTIMIZATION OF BEAM WEIGHTS UNDER DOSE-VOLUME RESTRICTIONS
    LANGER, M
    LEONG, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (08): : 1255 - 1260
  • [5] A generalization of dose volume histograms and dose-volume based IMRT objective functions for deformable tissue
    Rehbinder, H
    Korevaar, E
    Uhrdin, J
    Lof, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S622 - S622
  • [6] Multiple local minima in IMRT optimization based on dose-volume criteria
    Wu, QW
    Mohan, R
    [J]. MEDICAL PHYSICS, 2002, 29 (07) : 1514 - 1527
  • [7] Evaluation and ranking of lung IMRT treatment plans using a dose-volume biological-response index
    Miften, M
    Das, S
    Shafman, T
    Marks, L
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1293 - 1293
  • [8] LARGE-SCALE OPTIMIZATION OF BEAM WEIGHTS UNDER DOSE-VOLUME RESTRICTIONS
    LANGER, M
    BROWN, R
    URIE, M
    LEONG, J
    STRACHER, M
    SHAPIRO, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (04): : 887 - 893
  • [9] A Preliminary Study On Comparison of Dose-Volume Based Optimization and Equivalent Uniform Dose Based Optimization for IMRT Plans
    Subramaniam, B.
    Ding, W.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [10] Objective function based ranking method for selection of optimal beam angles in IMRT
    Ramar, Natarajan
    Meher, S. R.
    Ranganathan, Vaitheeswaran
    Perumal, Bojarajan
    Kumar, Prashant
    Anto, Gipson Joe
    Etti, S. Harikrishna
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 44 - 51