Flow-injection differential spectrophotometric pH selectivity system for the determination of cyclamate contaminants

被引:29
|
作者
Hlabangana, L [1 ]
Saurina, J [1 ]
Hernández-Cassou, S [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
aniline; cyclohexylamine; cyclamate contaminants analysis; differential flow-injection spectrophotometric detection;
D O I
10.1007/s00604-004-0310-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection system with differential spectrophotometric detection is proposed for the simultaneous determination of aniline and cyclohexylamine based on their reaction with 1,2-naphthoquinone-4-sulfonate (NQS). The pH is chosen to achieve selectivity since only aniline reacts at acidic pH whereas the two amines are derivatized in basic medium. The flow manifold comprises two reactors and two detection cells for developing and monitoring the reaction under selective and general (non-selective) conditions. A double beam spectrophotometer is used for differential detection, with two flow cells placed in the sample and reference holders. Figures of merit such as sensitivity, linear range, detection limit and precision are established. The evaluation of accuracy using a series of synthetic mixtures indicates overall prediction errors of 3% and 5% for aniline and cyclohexylamine, respectively. The method is applied to the determination of amine impurities in commercial sweeteners. Good concordance between the proposed and the standard chromatographic methods is found.
引用
收藏
页码:115 / 123
页数:9
相关论文
共 50 条
  • [1] Flow-Injection Differential Spectrophotometric pH Selectivity System for the Determination of Cyclamate Contaminants
    Leah Hlabangana
    Javier Saurina
    Santiago Hernández-Cassou
    [J]. Microchimica Acta, 2005, 150 : 115 - 123
  • [2] Flow-injection determination of amine contaminants in cyclamate samples based on temperature for controlling selectivity
    Saurina, J
    Hlabangana, L
    García-Milla, D
    Hernández-Cassou, S
    [J]. ANALYST, 2004, 129 (05) : 468 - 474
  • [3] SPECTROPHOTOMETRIC DETERMINATION OF PH BY FLOW-INJECTION
    PIA, SH
    WALTMAN, DP
    HILLMAN, DC
    STREET, KW
    [J]. ANALYTICA CHIMICA ACTA, 1990, 231 (01) : 21 - 26
  • [4] FLOW-INJECTION CHEMILUMINOMETRIC DETERMINATION OF SODIUM CYCLAMATE
    PSARELLIS, IM
    SARANTONIS, EG
    CALOKERINOS, AC
    [J]. ANALYTICA CHIMICA ACTA, 1993, 272 (02) : 265 - 270
  • [5] SPECTROPHOTOMETRIC DETERMINATION OF CALCIUM WITH A FLOW-INJECTION SYSTEM
    NAKAGAWA, G
    WADA, H
    WEI, C
    [J]. ANALYTICA CHIMICA ACTA, 1983, 145 (JAN) : 135 - 141
  • [6] Spectrophotometric determination of pKa values based on a pH gradient flow-injection system
    Saurina, J
    Hernández-Cassou, S
    Tauler, R
    Izquierdo-Ridorsa, A
    [J]. ANALYTICA CHIMICA ACTA, 2000, 408 (1-2) : 135 - 143
  • [7] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF CYCLAMATE IN LOW-CALORIE SOFT DRINKS AND SWEETENERS
    GOUVEIA, ST
    FATIBELLO, O
    NOBREGA, JD
    [J]. ANALYST, 1995, 120 (07) : 2009 - 2012
  • [8] Flow-injection spectrophotometric system for captopril determination in pharmaceuticals
    Suarez, Willian T.
    Madi, Alexandro A.
    de Figueiredo, Luiz C. S.
    Fatibello, Orlando
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2007, 18 (06) : 1215 - 1219
  • [9] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF NITRITE
    CHAURASIA, A
    VERMA, KK
    [J]. TALANTA, 1994, 41 (08) : 1275 - 1279
  • [10] Flow-injection spectrophotometric determination of hydrazine
    Ensafi, AA
    Naderi, B
    [J]. MICROCHEMICAL JOURNAL, 1997, 56 (03) : 269 - 275