Preoperative parathyroid scintigraphic lesion localization: Accuracy of various types of readings

被引:67
|
作者
Nichols, Kenneth J. [1 ]
Tomas, Maria B. [1 ]
Tronco, Gene G. [1 ]
Rini, Josephine N. [1 ]
Kunjummen, Biju D. [1 ]
Heller, Keith S. [3 ]
Sznyter, Laura A. [2 ]
Palestro, Christopher J. [1 ]
机构
[1] N Shore Long Isl Jewish Hlth System, Div Nucl Med & Mol Imaging, New Hyde Pk, NY 11040 USA
[2] N Shore Long Isl Jewish Hlth System, Dept Surg, New Hyde Pk, NY 11040 USA
[3] NYU, Sch Med, Div Endocrine Surg, New York, NY USA
关键词
D O I
10.1148/radiol.2481071066
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively compare the accuracy of various parathyroid scintigraphy readings for single-gland disease (SGD) and multigland disease (MGD) in patients with primary hyperparathyroidism, with histologic analysis as the reference standard. Materials and Methods: Institutional review board approval was obtained for this HIPAA-compliant study. Records of 462 patients with primary hyperparathyroidism who underwent preoperative imaging with a technetium 99m (Tc-99m) sestamibi and (TcO4-)-Tc-99m protocol that consisted of early and late pinhole 99mTc sestamibi, pinhole thyroid imaging, image subtraction, and single photon emission computed tomography (SPECT) were retrospectively reviewed. An experienced nuclear medicine physician without knowledge of other test results or of the final diagnoses graded images on a scale from 0 (definitely normal) to 4 (definitely abnormal). Early pinhole Tc-99m sestamibi images, late pinhole Tc-99m sestamibi images, subtraction images, SPECT images, early and late pinhole Tc-99m sestamibi images, all planar images, and all images-including SPECT images-were read in seven sessions. Receiver operating characteristic curves were generated for each session and were used to calculate sensitivity, specificity, and accuracy. Results: A total of 534 parathyroid lesions were excised. Of the 462 patients, 409 had one lesion, whereas 53 had multiple lesions. Reading all images together was more accurate (89%, P=.001) than was reading early (79%), late (85%), subtraction (86%), and SPECT (83%) images seperately; however, it was not significantly more accurate than reading planar images (88%) or early and late images together (87%). Reading all images was significantly less sensitive in the detection of lesions with a median weight of 600 mg or less than in the detection of lesions with a median weight of more than 600 mg (86% vs 94%, P=.004). Per-lesion sensitivity for reading all images was significantly higher for SGD than for MGD (90% vs 66%, P <.001). Sensitivity of reading all images together in the identification of patients with MGD was 62%. Conclusion: Reviewing early, late, and subtraction pinhole images together with SPECT images maximizes parathyroid lesion detection accuracy. Test sensitivity is adversely affected by decreasing lesion weight and MGD. (c) RSNA, 2008.
引用
收藏
页码:221 / 232
页数:12
相关论文
共 50 条
  • [1] SCINTIGRAPHIC TECHNIQUES IN PREOPERATIVE LOCALIZATION OF PARATHYROID ADENOMA
    KRAUSZ, Y
    HORNE, T
    HAIN, D
    CHISIN, R
    ATLAN, H
    [J]. ISRAEL JOURNAL OF MEDICAL SCIENCES, 1992, 28 (3-4): : 217 - 220
  • [2] Preoperative scintigraphic parathyroid gland localization in secondary hyperparathyroid patients treated with dialysis
    Toth, Zoltan
    Szabados, Lajos
    Krakomperger, Laszlo
    Egervari, Kristof
    Matyus, Janos
    Garai, Ildiko
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [3] PREOPERATIVE SCINTIGRAPHIC LOCATION OF PARATHYROID TUMORS
    LING, MCC
    OKERLUND, MD
    [J]. WESTERN JOURNAL OF MEDICINE, 1986, 144 (02): : 215 - 216
  • [4] Ultrasonography: Highly Accuracy Technique for Preoperative Localization of Parathyroid Adenoma
    Abboud, Bassani
    Sleilaty, Ghassan
    Rabaa, Lara
    Daher, Ronald
    Abou Zeid, Hicham
    Jabbour, Hicharn
    Hachem, Karnal
    Smayra, Tarek
    [J]. LARYNGOSCOPE, 2008, 118 (09): : 1574 - 1578
  • [5] Preoperative localization of parathyroid lesion: diagnostic usefulness of color doppler ultrasonography
    Mohammadi, Afshin
    Moloudi, Farzad
    Ghasemi-rad, Mohammad
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2012, 5 (01): : 80 - 86
  • [6] SPECT vs planar imaging for preoperative parathyroid lesion localization.
    Tomas, MB
    Torres, MA
    Bhuiya, T
    Afriyie, MO
    Attie, JN
    Palestro, CJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 1089 - 1089
  • [7] PREOPERATIVE PARATHYROID LOCALIZATION
    HOLLALLEN, RTJ
    [J]. BRITISH JOURNAL OF SURGERY, 1988, 75 (05) : 497 - 497
  • [8] PREOPERATIVE PARATHYROID LOCALIZATION
    EGDAHL, RH
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1979, 301 (10): : 548 - 549
  • [9] Accuracy of 2-Phase Parathyroid CT for the Preoperative Localization of Parathyroid Adenomas in Primary Hyperparathyroidism
    Griffith, B.
    Chaudhary, H.
    Mahmood, G.
    Carlin, A. M.
    Peterson, E.
    Singer, M.
    Patel, S. C.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (12) : 2373 - 2379
  • [10] PREOPERATIVE LOCALIZATION OF PARATHYROID LESIONS
    MATTAR, AG
    WRIGHT, E
    CHITTAL, S
    KWAN, A
    [J]. CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1985, 8 (03): : A160 - A160