An auxiliary frequency tracking system for general purpose lock-in amplifiers

被引:4
|
作者
Xie, Kai [1 ]
Chen, Liuhao [1 ]
Huang, Anfeng [1 ]
Zhao, Kai [1 ]
Zhang, Hanlu [2 ]
机构
[1] Xidian Univ, Sch Aerosp Sci & Technol, Xian 710071, Shaanxi, Peoples R China
[2] Xian Univ Posts & Telecommun, Sch Commun & Informat Engn, Xian 710121, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
lock-in amplifier; frequency tracking; weak signal detection; frequency drift;
D O I
10.1088/1361-6501/aa9d6a
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Lock-in amplifiers (LIAs) are designed to measure weak signals submerged by noise. This is achieved with a signal modulator to avoid low-frequency noise and a narrow-band filter to suppress out-of-band noise. In asynchronous measurement, even a slight frequency deviation between the modulator and the reference may lead to measurement error because the filter's passband is not flat. Because many commercial LIAs are unable to track frequency deviations, in this paper we propose an auxiliary frequency tracking system. We analyze the measurement error caused by the frequency deviation and propose both a tracking method and an auto-tracking system. This approach requires only three basic parameters, which can be obtained from any general purpose LIA via its communications interface, to calculate the frequency deviation from the phase difference. The proposed auxiliary tracking system is designed as a peripheral connected to the LIA's serial port, removing the need for an additional power supply. The test results verified the effectiveness of the proposed system; the modified commercial LIA (model SR-850) was able to track the frequency deviation and continuous drift. For step frequency deviations, a steady tracking error of less than 0.001% was achieved within three adjustments, and the worst tracking accuracy was still better than 0.1% for a continuous frequency drift. The tracking system can be used to expand the application scope of commercial LIAs, especially for remote measurements in which the modulation clock and the local reference are separated.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] HIGH-FREQUENCY SIGNAL TRACKING LOCK-IN SYSTEM
    MORESCO, M
    ZILLI, E
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1975, 46 (11): : 1582 - 1583
  • [2] LOCK-IN AMPLIFIERS
    不详
    [J]. MEASUREMENTS & CONTROL, 1995, (170): : 205 - 206
  • [3] LOCK-IN AMPLIFIERS
    OHAVER, TC
    [J]. JOURNAL OF CHEMICAL EDUCATION, 1972, 49 (04) : A211 - &
  • [4] LOCK-IN AMPLIFIERS
    不详
    [J]. MEASUREMENTS & CONTROL, 1994, (164): : 173 - 174
  • [5] ADVANCES IN LOCK-IN AMPLIFIERS
    MEADE, ML
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1982, 15 (04): : 395 - 403
  • [6] Random sampling in high-frequency digital lock-in amplifiers
    Sonnaillon, M. O.
    Urteaga, R.
    Bonetto, F. J.
    [J]. LATIN AMERICAN APPLIED RESEARCH, 2006, 36 (03) : 181 - 186
  • [7] LOCK-IN AMPLIFIERS .1.
    OHAVER, TC
    [J]. JOURNAL OF CHEMICAL EDUCATION, 1972, 49 (03) : A131 - &
  • [8] Signal measurements with lock-in amplifiers
    Lake Shore Cryotronics, United States
    [J]. Electron World, 2022, 2014 (26-29):
  • [9] Lock-in amplifiers for AMR sensors
    Diaz-Michelena, Marina
    Cobos, Pedro
    Aroca, Claudio
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2015, 222 : 149 - 159
  • [10] Research progress of lock-in amplifiers
    Guo, Zhong-Kai
    Li, Yong-Gang
    Yu, Bo-Cheng
    Zhou, Shi-Chao
    Meng, Qing-Yu
    Lu, Xin-Xin
    Huang, Yi-Fan
    Liu, Gui-Peng
    Lu, Jun
    [J]. ACTA PHYSICA SINICA, 2023, 72 (22)