Hemodynamic Changes During Heart Displacement in Aorta No-Touch Off-Pump Coronary Artery Bypass Surgery: A Pilot Study

被引:2
|
作者
Carvalho, Alexandre R. [1 ,2 ,3 ]
Guizilini, Solange [4 ,5 ]
Murai, Gustavo M. [1 ,2 ,3 ]
Begot, Isis [4 ,5 ]
Rocco, Isadora S. [4 ,5 ]
Hossne, Nelson A., Jr. [4 ,5 ]
Chamlian, Eduardo G. [1 ,2 ,3 ]
Santos, Joao Manoel T. [1 ]
Macedo, Ricardo A. [1 ]
Lisboa, Gustavo C. O. [1 ]
Nasciutti, Alberto C. [1 ]
Santos, Carlos Eduardo R. [1 ]
Figueiredo, Joao Paulo M. [1 ]
Gomes, Walter J. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Policlin Hosp, Sao Jose Dos Campos, SP, Brazil
[2] Pirajussara Gen Hosp, SPDM, Sao Paulo, SP, Brazil
[3] Clin Hosp Luzia Pinho Melo, SPDM, Sao Paulo, SP, Brazil
[4] Escola Paulista Med, Discipline Cardiovasc Surg, Sao Paulo, SP, Brazil
[5] Univ Fed Sao Paulo Unifesp, Sao Paulo Hosp, Sao Paulo, SP, Brazil
关键词
Coronary Artery Bypass; Off-Pump; Stroke; Intracranial Embolism; Hemodynamics; ON-PUMP; NEUROLOGIC COMPLICATIONS; CARDIAC-OUTPUT; GRAFT PATENCY; METAANALYSIS; MANIPULATION; OUTCOMES; COSTS;
D O I
10.21470/1678-9741-2018-0090
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the sequential changes of hemodynamic and metabolic parameters in patients who underwent aorta no-touch off-pump coronary artery bypass surgery (OPCAB). Methods: Prospective study involving twenty-seven consecutive patients who underwent aorta no-touch OPCAB. The FloTrac/PreSep/Vigileo (TM) system (Edwards Lifesciences) was used to continuously record heart rate (HR), mean arterial blood pressure (MABP), central venous pressure (CVP), continuous cardiac index (FCI), stroke volume (SV), stroke volume variation (SW), and central venous oxygen saturation (ScvO(2)). The parameters were assessed 5 min before, during and 5 min after each anastomosis (left anterior descending [LAD], posterior descending [PD], obtuse marginal [OM] and diagonal [Dg]). Postoperative lactate was also evaluated. Results: There was no significant change in HR and MABP for all anastomoses, except for MABP during PD grafting (-10.1 +/- 2.7 mmHg, P=0.03). There was a significant decrease in ScvO(2) only during PD and OM anastomoses (-9.4 +/- 0.4, P=0.03; -4.4 +/- 0.4, P=0.02; respectively). CVP drop after PD manipulation was strongly associated with a higher lactate during the first hours after surgery (r=-0.82; P=0.001). These hemodynamic changes were transient and entirely recovered after the heart was returned to its anatomical position. No significant differences were observed in FCI, SW, or the systemic vascular resistance index (SVRI) during all anastomoses, except for a drop in SVRI during PD grafting (-8.03 +/- 2.3, P=0.007). SV tended to decrease during the procedure in all territories, but with statistically significant drop only in PD and OM grafting (-10.4 +/- 1.2, P=0.02; -13.6 +/- 5.1, P=0.007; respectively). Conclusion: Heart displacement for performing aorta no-touch OPCAB is well tolerated, with transient and endurable hemodynamic variations.
引用
收藏
页码:469 / 475
页数:7
相关论文
共 50 条
  • [1] Predictors of prolonged mechanical ventilation following aorta no-touch off-pump coronary artery bypass surgery
    Prapas, Sotirios N.
    Panagiotopoutos, Ioannis A.
    Abdelsalam, Ashraf Hamed
    Kotsis, Vasitios N.
    Protogeros, Dimitrios A.
    Linardakis, Ioannis N.
    Danou, Fodni N.
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 32 (03) : 488 - 492
  • [2] No-touch aorta off-pump coronary surgery: The effect on stroke
    Lev-Ran, O
    Braunstein, R
    Sharony, R
    Kramer, A
    Paz, Y
    Mohr, R
    Uretzky, G
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (02): : 307 - 313
  • [3] Hemodynamic changes during off-pump coronary artery bypass graft surgery
    D'Ancona, G
    Karamanoukian, H
    Bergsland, J
    Salerno, T
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2000, 14 (02) : 235 - 236
  • [4] Hemodynamic changes during displacement of the beating heart using epicardial stabilization for off-pump coronary artery bypass graft surgery
    Mishra, M
    Malhotra, R
    Mishra, A
    Meharwal, ZS
    Trehan, N
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (06) : 685 - 690
  • [5] Advances in coronary artery bypass surgery. Off pump coronary artery bypass grafting and "no-touch" of the ascending aorta
    Lopez-Menendez, Jose
    Hyka, Javier Miguelena
    [J]. CIRUGIA CARDIOVASCULAR, 2023, 30 (02): : 90 - 96
  • [6] Hemodynamic changes during off-pump coronary artery bypass grafting
    Ashraf Fayad
    Homer Yang
    [J]. Canadian Journal of Anesthesia, 2006, 53 (Suppl 1): : 26476 - 26476
  • [7] Management of porcelain aorta and calcified great vessels in coronary artery bypass grafting with off-pump and no-touch technology
    Bittner, HB
    Savitt, MA
    [J]. ANNALS OF THORACIC SURGERY, 2001, 72 (04): : 1378 - 1380
  • [8] Aorta No-Touch Off-Pump Coronary Artery Revascularization in Octogenarians: 5 Years' Experience
    Prapas, Sotirios N.
    Panagiotopoulos, Ioannis A.
    Pentchev, Dimitar N.
    Ayyad, Mohamed A. Salama
    Protogeros, Dimitrios A.
    Kotsis, Vasilios N.
    Linardakis, Ioannis N.
    Tzanavaras, Theofanis P.
    Stratigi, Poly T.
    [J]. HEART SURGERY FORUM, 2009, 12 (06): : E349 - E353
  • [9] Short-term outcome of attention and executive functions from aorta no-touch and traditional off-pump coronary artery bypass surgery
    Szwed, Krzysztof
    Pawliszak, Wojciech
    Anisimowicz, Lech
    Bucinski, Adam
    Borkowska, Alina
    [J]. WORLD JOURNAL OF BIOLOGICAL PSYCHIATRY, 2014, 15 (05): : 397 - 403
  • [10] A New No-Touch Aorta Technique for Arterial-Source, Off-Pump Coronary Surgery
    Cirillo, Marco
    Messina, Antonio
    Dalla Tomba, Margherita
    Brunelli, Federico
    Mhagna, Zean
    Villa, Emmanuel
    Dettori, Ernesto
    Troise, Giovanni
    [J]. ANNALS OF THORACIC SURGERY, 2009, 88 (04): : E46 - E47