Study of anxiety in patients with glaucoma undergoing standard automated perimetry and optical coherence tomography - A prospective comparative study

被引:6
|
作者
Kaliaperumal, Subashini [1 ]
Janani, V. S. [1 ]
Menon, Vikas [2 ]
Sarkar, Sandip [1 ]
Behera, Geeta [1 ]
Kattamani, Shivanand [2 ]
机构
[1] Jawaharlal Inst Postgrad Med Educ & Res, Dept Ophthalmol, Pondicherry, India
[2] Jawaharlal Inst Postgrad Med Educ & Res, Dept Psychiat, Pondicherry, India
关键词
Anxiety; glaucoma; optical coherence tomography (OCT); State-Trait Anxiety Inventory [STAI; visual field testing;
D O I
10.4103/ijo.IJO_508_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the anxiety levels related to visual field testing and optical coherence tomography (OCT) in patients with glaucoma. Methods: This prospective, comparative study was conducted on patients with glaucoma. The participants' anxiety traits were assessed using the State-Trait Anxiety Inventory [STAI]. Before visual field testing on Humphrey visual field analyzer (HVF) and retinal nerve fiber analysis on OCT, the participants completed Form Y1 to measure the current pretest level or 'State' anxiety [pretest anxiety]. Immediately after testing, participants were administered the Form Y1 questionnaire to assess the induced anxiety level during the testing [Intratest anxiety]. Results: A total of 228 patients were enrolled with 152 participants in the HVF group and 76 in the OCT group. The mean age of the participants in the HVF group was 57.2 +/- 20.8 years and in the OCT group was 56.8 +/- 20 years. There was no significant difference in trait and pretest anxiety between the HVF group and the OCT group (P = 0.971 and P = 0.716). Intratest test anxiety score was slightly higher in the HVF group (HVF: 42.13 +/- 10.63, OCT: 40.71 +/- 9.76; P = 0.33). The anxiety scores were higher when the experience of previous HVF tests was <2 and least when the number of tests exceeded five. Conclusion: Automated perimetry induces slightly more anxiety than OCT, which may affect test performance. The measured anxiety reduces as patients gain familiarity with the test with experience. This adds credence to the recommendation of more frequent visual field testing in newly diagnosed glaucoma patients.
引用
收藏
页码:2883 / 2887
页数:5
相关论文
共 50 条
  • [1] Integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics
    Dimitrios Bizios
    Anders Heijl
    Boel Bengtsson
    BMC Ophthalmology, 11
  • [2] Integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics
    Bizios, Dimitrios
    Heijl, Anders
    Bengtsson, Boel
    BMC OPHTHALMOLOGY, 2011, 11
  • [3] Relationship between Spectral-Domain Optical Coherence Tomography and Standard Automated Perimetry in Healthy and Glaucoma Patients
    Abadia, Beatriz
    Ferreras, Antonio
    Calvo, Pilar
    Ara, Mirian
    Ferrandez, Blanca
    Otin, Sofia
    Frezzotti, Paolo
    Pablo, Luis E.
    Figus, Michele
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [4] High Definition Optical Coherence Tomography and Standard Automated Perimetry Dataset Generator for Glaucoma Diagnosis
    Dias, Marcelo
    Vidotti, Vanessa
    Costa, Vital Paulino
    Gomi, Edson Satoshi
    2009 FIRST ANNUAL ORNL BIOMEDICAL SCIENCE & ENGINEERING CONFERENCE: EXPLORING THE INTERSECTIONS OF INTERDISCIPLINARY BIOMEDICAL RESEARCH, 2009, : 96 - +
  • [5] Comparative study of glaucoma using ultrahigh resolution and standard optical coherence tomography
    Schuman, JS
    Ko, TH
    Fujimoto, JG
    Mattox, C
    Paunescu, L
    Ishikawa, H
    Wollstein, G
    Drexler, W
    Kowalevicz, AM
    Hartl, I
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U269 - U269
  • [6] Short Wavelength Automated Perimetry, Standard Automated Perimetry, and Optical Coherence Tomography in Dominant Optic Atrophy
    Lombardo, Marco
    Cusumano, Andrea
    Mancino, Raffaele
    Aiello, Francesco
    Sorge, Roberto Pietro
    Nucci, Carlo
    Cesareo, Massimo
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (07)
  • [7] Associations Between Ethnicity and Race with Times for Detection of Glaucoma Progression by Standard Automated Perimetry and Optical Coherence Tomography
    Franco Beniz, Luiz Arthur
    Jammal, Alessandro A.
    da Costa, Douglas R.
    Mariottoni, Eduardo
    Swaminathan, Swarup Sai
    Medeiros, Felipe
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [8] Diagnostic Consistency and Relation Between Optical Coherence Tomography and Standard Automated Perimetry in Primary Open-Angle Glaucoma
    Toprak, Ibrahim
    Yaylali, Volkan
    Yildirim, Cem
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (02) : 185 - 190
  • [9] Agreement Among Spectral-Domain Optical Coherence Tomography, Standard Automated Perimetry, and Stereophotography in the Detection of Glaucoma Progression
    Banegas, Sebastian A.
    Anton, Alfonso
    Morilla-Grasa, Antonio
    Bogado, Marco
    Ayala, Eleonora M.
    Moreno-Montanes, Javier
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (02) : 1253 - 1260
  • [10] Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma
    Kampmeier, J
    Eisert, B
    Buchwald, HJ
    Lang, GK
    Lang, GE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (03) : 157 - 167