Performance Analysis of Air Breathing Proton Exchange Membrane Fuel Cell Stack (PEMFCS) At Different Operating Condition

被引:5
|
作者
Sunil, V. [1 ]
Siva, G. Venkata [1 ]
Yoganjaneyulu, G. [2 ]
Ravikumar, V. V. [2 ]
机构
[1] Al Habeeb Coll Engn & Technol, Dept Mech Engn, Hyderabad 501503, Andhra Pradesh, India
[2] Natl Inst Technol, Dept MME, Tiruchirappalli 620015, Tamil Nadu, India
关键词
Convection; Draught; Fuel cell stack; Fuel cell test station; Humidity;
D O I
10.1088/1757-899X/225/1/012286
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The answer for an emission free power source in future is in the form of fuel cells which combine hydrogen and oxygen producing electricity and a harmless by product-water. A proton exchange membrane (PEM) fuel cell is ideal for automotive applications. A single cell cannot supply the essential power for any application. Hence PEM fuel cell stacks are used. The effect of different operating parameters namely: type of convection, type of draught, hydrogen flow rate, hydrogen inlet pressure, ambient temperature and humidity, hydrogen humidity, cell orientation on the performance of air breathing PEM fuel cell stack was analyzed using a computerized fuel cell test station. Then, the fuel cell stack was subjected to different load conditions. It was found that the stack performs very poorly at full capacity (runs only for 30 min. but runs for 3 hours at 50% capacity). Hence, a detailed study was undertaken to maximize the duration of the stack's performance at peak load.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Performance of a proton exchange membrane fuel cell stack
    Johnson, R
    Morgan, C
    Witmer, D
    Johnson, T
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2001, 26 (08) : 879 - 887
  • [2] Numerical studies on an air-breathing proton exchange membrane (PEM) fuel cell stack
    Zhang, Y.
    Mawardi, A.
    Pitchumani, R.
    [J]. JOURNAL OF POWER SOURCES, 2007, 173 (01) : 264 - 276
  • [3] Effects of operating conditions on the performance uniformity of the proton-exchange membrane fuel cell stack
    Zhu, Xinning
    Su, Liang
    Wang, Xi
    Chen, Rui
    Ji, Dongsheng
    Ma, Yao
    Wu, Linjing
    Zhang, Jianbo
    Zhou, Wei
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2023, 281
  • [4] Design and numerical analysis of air-cooled proton exchange membrane fuel cell stack for performance optimization
    Yin, Cong
    Gao, Yan
    Li, Kai
    Wu, Di
    Song, Yating
    Tang, Hao
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 245
  • [5] Membrane performance comparison in a proton exchange membrane fuel cell (PEMFC) stack
    Kim, Sunhoe
    Hong, Inkwon
    [J]. JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2010, 16 (06) : 901 - 905
  • [6] EFFECT OF COMBINATIONS OF DIFFERENT OPERATING PARAMETERS ON PERFORMANCE OF PROTON EXCHANGE MEMBRANE FUEL CELL
    Thiyagarajan, Prem Kumar
    Jeganathan, Kanchana
    Paivthalingal, Manoj Kumar
    Rajappa, Naveen
    [J]. THERMAL SCIENCE, 2021, 25 (04): : 2731 - 2740
  • [7] Performance Analysis on Planar Micro PDMS Proton Exchange Membrane Fuel Cell Stack
    Peng, Rong-Gui
    Chen, Tang-Yuan
    Hsu, Yi-Ja
    Chen, Chiun-Hsun
    [J]. JOURNAL OF THE CHINESE SOCIETY OF MECHANICAL ENGINEERS, 2011, 32 (03): : 189 - 198
  • [8] Study of the distribution of air flow in a proton exchange membrane fuel cell stack
    Mustata, Radu
    Valino, Luis
    Barreras, Felix
    Isabel Gil, Maria
    Lozano, Antonio
    [J]. JOURNAL OF POWER SOURCES, 2009, 192 (01) : 185 - 189
  • [9] Sensitivity analysis of operating parameters on a 65 kW proton exchange membrane fuel cell stack performances
    Ji, Xuefeng
    Wang, Xiaobing
    Li, Yan
    Guo, Jianqiang
    Yang, Zirong
    Hao, Dong
    [J]. ENERGY REPORTS, 2022, 8 : 521 - 527
  • [10] Mechanical design and analysis of a proton exchange membrane fuel cell stack
    Chung, Tien-Tung
    Lin, Chin-Te
    Shiu, Huan-Ruei
    [J]. JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2016, 39 (03) : 353 - 362