The capture of Escherichia coli O157:H7 for Light addressable Potentiometric Sensor (LAPS) using two different types of magnetic beads

被引:11
|
作者
Tu, SI
Uknalis, J
Gore, M
Irwin, P
机构
[1] USDA, ARS, NAA, Eastern Reg Res Ctr, Wyndmoor, PA 19038 USA
[2] Polysci Inc, Warrington, PA 18976 USA
关键词
D O I
10.1111/j.1745-4581.2002.tb00025.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Two types of commercially available, streptavidin-coated magnetic beads (SAMB) were labeled with the same biotinylated anti E. coli O157 antibodies. Labeled SAMB and other necessary antibody derivatives needed for Light-addressable Potentiometric Sensor (LAPS) detection were used to capture E. coli O157:H7 in solution. The LAPS signal intensity was then used to determine the overall bacterial capture efficiency. The static and hydrodynamic properties of the beads were then used to correlate with determined efficiencies. It was found that the capture increased as the total mass of SAMB increased. Also, greater capture with SAMB of a higher. density was observed with the same bead mass. In addition, the SAMB of higher density also required less time of rocking to reach a maximum capture. These observations are in agreement with the predictions from the hydrodynamic properties of tested SAMB.
引用
收藏
页码:185 / 195
页数:11
相关论文
共 50 条
  • [1] Application of streptavidin coated magnetic beads for detecting Escherichia coli O157:H7 by light addressable potentiometric sensor (LAPS)
    Tu, S
    Uknalis, J
    Irwin, P
    Patterson, D
    Yu, LSL
    [J]. BIOPHYSICAL JOURNAL, 2000, 78 (01) : 254A - 254A
  • [2] The use of light addressable potentiometric sensor (LAPS) to detect magnetically captured Escherichia coli O157:H7 in ground beef
    Tu, SI
    Uknalis, J
    Irwin, P
    Yu, LSL
    [J]. PHOTONIC DETECTION AND INTERVENTION TECHNOLOGIES FOR SAFE FOOD, 2001, 4206 : 1 - 6
  • [3] Use of a light-addressable potentiometric sensor for the detection of Escherichia coli O157:H7
    Gehring, AG
    Patterson, DL
    Tu, SI
    [J]. ANALYTICAL BIOCHEMISTRY, 1998, 258 (02) : 293 - 298
  • [4] Detection of immunomagnetic bead captured Escherichia coli O157:H7 by light addressable potentiometric sensor
    Tu, SI
    Uknalis, J
    Gehring, A
    [J]. JOURNAL OF RAPID METHODS AND AUTOMATION IN MICROBIOLOGY, 1999, 7 (02): : 69 - 79
  • [5] Capture of Escherichia coli O157:H7 Using Immunomagnetic Beads of Different Size and Antibody Conjugating Chemistry
    Tu, Shu-I
    Reed, Sue
    Gehring, Andrew
    He, Yiping
    Paoli, George
    [J]. SENSORS, 2009, 9 (02) : 717 - 730
  • [6] Escherichia coli O157:H7
    Weir, E
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 2000, 163 (02) : 205 - 205
  • [7] Escherichia coli O157:H7
    Riemann, HP
    Cliver, DO
    [J]. VETERINARY CLINICS OF NORTH AMERICA-FOOD ANIMAL PRACTICE, 1998, 14 (01) : 41 - +
  • [8] Escherichia coli O157:H7
    Hartigan, PJ
    [J]. IRISH VETERINARY JOURNAL, 1997, 50 (02) : 91 - +
  • [9] Escherichia coli O157:H7
    Mead, PS
    Griffin, PM
    [J]. LANCET, 1998, 352 (9135): : 1207 - 1212
  • [10] Escherichia coli O157:H7
    Tarr, PI
    Neill, MA
    [J]. GASTROENTEROLOGY CLINICS OF NORTH AMERICA, 2001, 30 (03) : 735 - +