Reducing radiation exposure during procedures performed in the electrophysiology laboratory

被引:12
|
作者
Thibault, Bernard [1 ,2 ]
Macle, Laurent [1 ,2 ]
Mondesert, Blandine [1 ,2 ]
Dubuc, Marc [1 ,2 ]
Shohoudi, Azadeh [3 ]
Dyrda, Katia [1 ,2 ]
Guerra, Peter G. [1 ,2 ]
Rivard, Lena [1 ,2 ]
Roy, Denis [1 ,2 ]
Talajic, Mario [1 ,2 ]
Khairy, Paul [1 ,2 ]
机构
[1] Univ Montreal, Montreal Heart Inst, Electrophysiol Serv, Montreal, PQ, Canada
[2] Univ Montreal, Dept Med, Montreal, PQ, Canada
[3] Univ Montreal, Montreal Hlth Innovat Coordinating Ctr, Montreal Heart Innovat Coordinating Ctr, Montrel Heart Inst, Montreal, PQ, Canada
关键词
cardiac implantable electronic device; catheter ablation; fluoroscopy; interventional electrophysiology; radiation exposure; radiation safety; CARDIAC RESYNCHRONIZATION THERAPY; ATRIAL-FIBRILLATION ABLATION; CATHETER TRACKING SYSTEM; IMAGE INTEGRATION MODULE; PULMONARY VEIN ISOLATION; INITIAL-EXPERIENCE; INTERVENTIONAL CARDIOLOGY; RANDOMIZED-TRIAL; IMPLANTATION; PATIENT;
D O I
10.1111/jce.13373
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Expert societies recently published strong recommendations to reduce the exposure of patients and staff to ionizing radiation (IR) during interventional and electrophysiology (EP) procedures. However, adherence to these guidelines remains difficult and the impact of implementing such recommendations is poorly characterized. Methods and results: We conducted a single-center cohort study to quantify radiation exposure over time in three EP laboratories at the Montreal Heart Institute during 5,546 consecutive procedures from 2012 to 2015 by 11 primary operators. Overall, 2,618 (47.2%) procedures were catheter-based and 2,928 (52.8%) were device interventions. Interventions to reduce radiation exposure included educational initiatives to raise awareness (i.e., limiting cine acquisition, patient position, table height), slower frame rate, lower radiation dose per pulse, collimation, and integration with 3-D mapping systems and/or MediGuide technology. An 85% reduction in IR exposure was observed from 2012 to 2015, with the mean dose-area-product (DAP) decreasing from 7.65 +/- 0.05 Gy.cm(2) to 1.15 +/- 0.04 Gy.cm(2) (P < 0.001). This was true for catheter-based procedures (mean DAP 16.99 +/- 0.08 to 2.00 +/- 0.06 Gy.cm(2), P < 0.001) and device interventions (mean DAP 4.18 +/- 0.06 to 0.64 +/- 0.05 Gy.cm(2), P < 0.001). The median effective dose of IR recorded per quarter by 282 cervical dosimeters on EP staff decreased from 0.57 (IQR 0.18, 1.03) mSv in 2012 to 0.00 (IQR 0.00, 0.19) mSv in 2015, P < 0.001. Conclusion: Enforcing good clinical practices with simple measures and low-dose fluoroscopy settings are highly effective in reducing IR exposure in the EP lab. These promising results should encourage other EP labs to adopt similar protective measures.
引用
收藏
页码:308 / 315
页数:8
相关论文
共 50 条
  • [1] Reducing radiation exposure in the electrophysiology laboratory: A work in progress
    Gianni, Carola
    Natale, Andrea
    HEART RHYTHM, 2017, 14 (06) : 817 - 818
  • [2] Physicians' exposure to radiation during electrophysiology procedures
    Faroux, Laurent
    Daval, Charline
    Lesaffre, Francois
    Blanpain, Thierry
    Chabert, Jean-Pierre
    Martin, Angeline
    Guinot, Mathias
    Luconi, Nicolas
    Espinosa, Madeline
    Nazeyrollas, Pierre
    Tourneux, Christophe
    Metz, Damien
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2019, 55 (02) : 233 - 237
  • [3] Physicians’ exposure to radiation during electrophysiology procedures
    Laurent Faroux
    Charline Daval
    François Lesaffre
    Thierry Blanpain
    Jean-Pierre Chabert
    Angeline Martin
    Mathias Guinot
    Nicolas Luconi
    Madeline Espinosa
    Pierre Nazeyrollas
    Christophe Tourneux
    Damien Metz
    Journal of Interventional Cardiac Electrophysiology, 2019, 55 : 233 - 237
  • [4] Reducing Radiation Exposure in the Electrophysiology Laboratory: It is More Than Just Fluoroscopy Times!
    Nof, Eyal
    Lane, Christopher
    Cazalas, Maxime
    Cuchet-Soubelet, Elisabeth
    Michaud, Gregory F.
    John, Roy M.
    Tedrow, Usha
    Koplan, Bruce A.
    Stevenson, William G.
    Epstein, Laurence M.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (01): : 136 - 145
  • [5] Radiation exposure during electrophysiology procedures: results from the EPIC global survey
    Ernst, S.
    Chung, M. K.
    Russo, A.
    Hoffmann, E.
    Eisenberg, S.
    Birgesdotter-Green, U.
    Blomstroem-Lundquist, C.
    Poole, J.
    EUROPEAN HEART JOURNAL, 2012, 33 : 695 - 695
  • [6] Reduction of radiation exposure in the cardiac electrophysiology laboratory
    Wittkampf, FHM
    Wever, EFD
    Vos, K
    Geleijns, J
    Schalij, MJ
    Van der Tol, J
    De Medina, EOR
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (11): : 1638 - 1644
  • [7] Utilization of a Radiation Safety Time-Out Reduces Radiation Exposure During Electrophysiology Procedures
    Aizer, Anthony
    Qiu, Jessica K.
    Cheng, Austin, V
    Wu, Patrick B.
    Holmes, Douglas S.
    Wagner, Steven R.
    Bernstein, Scott A.
    Park, David S.
    Cartolano, Barbara
    Barbhaiya, Chirag R.
    Chinitz, Larry A.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (05) : 626 - 634
  • [8] How significant is the radiation exposure during electrophysiology study and ablation procedures for supraventricular tachycardia?
    Bagchi, Avishek
    Vadivelu, Ramalingam
    Rathi, Chetan
    Chavan, Bhavesh Gunaji
    Lokhandwala, Yash
    INDIAN HEART JOURNAL, 2021, 73 (02) : 221 - 222
  • [9] Practical techniques for reducing radiation exposure during cerebral angiography procedures
    Pearl, Monica S.
    Torok, Collin
    Wang, Jiangxia
    Wyse, Emily
    Mahesh, Mahadevappa
    Gailloud, Philippe
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (02) : 141 - 145
  • [10] Radiation exposure to anesthesia personnel: The impact of an electrophysiology laboratory
    Katz, JD
    ANESTHESIA AND ANALGESIA, 2005, 101 (06): : 1725 - 1726