Stabilize OMOG photomask post-repair CD variation by cleaning strategy and post-repair treatment

被引:0
|
作者
Shen, Vincent [1 ]
Tzeng, Josh [1 ]
Huang, Kuang [1 ]
Chang, Vic [1 ]
机构
[1] Photron DNP Mask Corp, 6,Li Hsin 7th Rd,Sci Pk, Hsinchu, Taiwan
关键词
OMOG; repair; CD (Critical Dimension); cleaning; passivation; nitrogen composition;
D O I
10.1117/12.2277685
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
With wafer technology node migrating to 14nm, the noise of wafer critical dimension (CD) control from photomask become more significant due to a mask thickness no longer thin relative to the dimensions. Therefore, the Opaque MoSi-On-Glass (OMOG) photomask is widely used for high-end wafer production because its thin structure is an advantage for 3D electromagnetic field (3DEMF) mask modeling. In other words, it also means the CD control in such high-end wafer product become more and more important. The absorber layer of OMOG is composed of MoSiN which has faster etching rate. Although such kind of MoSiN can help repairing dark defect faster, it also bring some extra etchings what lead to over repair that impact photomask's CD control and yield. In order to stabilize the post-repair CD variation, we performed several treatments at pre-repair cleaning and a post-repair treatment to stabilize film properties. In addition, we also performed compositional analysis by EDX line scan to compare the compositional differences.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Imaging of ventricular septal defect: Native and post-repair
    Fusco, Flavia
    Borrelli, Nunzia
    Palma, Michela
    Sarubbi, Berardo
    Scognamiglio, Giancarlo
    INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE, 2022, 7
  • [2] Sutureless Repair With Extended Atriotomy for Post-Repair Pulmonary Venous Obstruction
    Yoneyama, Fumiya
    Caldarone, Christopher A.
    ANNALS OF THORACIC SURGERY, 2022, 114 (03): : E177 - E179
  • [3] Volcanic resurfacing of Io: Post-repair HST imaging
    Spencer, JR
    McEwen, AS
    McGrath, MA
    Sartoretti, P
    Nash, DB
    Noll, KS
    Gilmore, D
    ICARUS, 1997, 127 (01) : 221 - 237
  • [4] Laser vibrometry for bridge post-repair investigatio n
    Schmieder, Marcus
    Taylor-Noonan, Alex
    Heere, Roland
    Chen, S. E.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 3806 - 3811
  • [5] Alfieri Repair for Post-Repair Mitral Systolic Anterior Motion in a Young Child
    Khalpey, Zain
    Baird, Christopher W.
    Myers, Patrick O.
    ANNALS OF THORACIC SURGERY, 2013, 95 (04): : 1452 - 1453
  • [6] POST-REPAIR DRYING AND FIRING OF OPEN-HEARTH FURNACES
    BRUK, YG
    VAKHRUSHEV, AS
    VSHIVKOV, VA
    IVANOV, VF
    YAKOVLEV, AP
    METALLURGIST, 1977, 21 (5-6) : 308 - 309
  • [7] Prediction of Mitral Valve Repair: Pre-Repair versus Virtual Repair versus Post-Repair
    Yeo, MyungGu
    Nguyen, Tom T.
    McPherson, David D.
    Kim, Hyunggun
    CIRCULATION, 2018, 138
  • [8] Four Years Post-Repair of a Giant Ascending Aortic Aneurysm
    Al-Ebrahim, Khaled E.
    Jabbad, Husain H.
    Abdelrahman, Abdelrahman M.
    Al-Assal, Ahmed A.
    Ghobashy, Ragab S.
    JOURNAL OF CARDIAC SURGERY, 2010, 25 (05) : 568 - 569
  • [9] INTRACRANIAL VESSEL STIFFNESS IN POST-REPAIR PATIENTS WITH AORTIC COARCTATION
    Howe, Peter
    Wong, Rachel
    Ahmad, Waheed
    Spratt, Neil
    Levi, Chris
    Collins, Nicholas
    JOURNAL OF HYPERTENSION, 2016, 34 : E312 - E312
  • [10] Inguinal hernia: aetiology, diagnosis, post-repair pain and compensation
    O'Rourke, Michael G. E.
    O'Rourke, Thomas R.
    ANZ JOURNAL OF SURGERY, 2012, 82 (04) : 201 - 206