Reevaluating multicolor flow cytometry to assess microbial viability

被引:43
|
作者
Buysschaert, Benjamin [1 ]
Byloos, Bo [1 ,2 ]
Leys, Natalie [2 ]
Van Houdt, Rob [2 ]
Boon, Nico [1 ]
机构
[1] Univ Ghent, CMET, Coupure Links 653, B-9000 Ghent, Belgium
[2] Belgian Nucl Res Ctr SCK CEN, Microbiol Unit, Boeretang 200, B-2400 Mol, Belgium
关键词
Functionality; Protocols; Viability; SYTO; Multicolor FCM; ESCHERICHIA-COLI O157-H7; FED-BATCH CULTURES; NUCLEIC-ACID DYES; BACTERIAL VIABILITY; PHYSIOLOGICAL-STATE; PROPIDIUM IODIDE; NILE RED; BACILLUS-LICHENIFORMIS; SUCCINIMIDYL ESTER; LACTOCOCCUS-LACTIS;
D O I
10.1007/s00253-016-7837-5
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Flow cytometry is a rapid and quantitative method to determine bacterial viability. Although different stains can be used to establish viability, staining protocols are inconsistent and lack a general optimization approach. Very few "true" multicolor protocols, where dyes are combined in one sample, have been developed for microbiological applications. In this mini-review, the discrepancy between protocols for cell-permeant nucleic acid and functional stains are discussed as well as their use as viability dyes. Furthermore, optimization of staining protocols for a specific setup are described. Original data using the red-excitable SYTO dyes SYTO 59 to 64 and SYTO 17, combined with functional stains, for double and triple staining applications is also included. As each dye and dye combination behaves differently within a certain combination of medium matrix, microorganism, and instrument, protocols need to be tuned to obtain reproducible results. Therefore, single, double, and triple stains are reviewed, including the different parameters that influence staining such as stain kinetics, optimal stain concentration, and the effect of the chelator EDTA as membrane permeabilizer. In the last section, we highlight the need to investigate the stability of multicolor assays to ensure correct results as multiwell autoloaders are now commonly used.
引用
收藏
页码:9037 / 9051
页数:15
相关论文
共 50 条
  • [1] Reevaluating multicolor flow cytometry to assess microbial viability
    Benjamin Buysschaert
    Bo Byloos
    Natalie Leys
    Rob Van Houdt
    Nico Boon
    Applied Microbiology and Biotechnology, 2016, 100 : 9037 - 9051
  • [2] Design of a multicolor panel to assess intracellular and surface molecules by flow cytometry
    Mateus, Jose
    Lasso, Paola
    Mario Gonzalez, John
    Judith Puerta, Concepcion
    Cuellar, Adriana
    BIOMEDICA, 2013, 33 (04): : 660 - 672
  • [3] A quick flow cytometry protocol to assess Helicobacter pylori viability
    Alba, Claudio
    Marin, Alicia C.
    McNicholl, Adrian G.
    Montalban-Arques, Ana
    Mora-Gutierrez, Irene
    Jose Sanchez-Arroyo, Antonio
    Soler, Tamara
    Garcia-Fresnadillo, David
    Gisbert, Javier P.
    Alarcon, Teresa
    Bernardo, David
    JOURNAL OF MICROBIOLOGICAL METHODS, 2020, 177
  • [4] Compensation in multicolor flow cytometry
    Szaloki, Gabor
    Goda, Katalin
    CYTOMETRY PART A, 2015, 87A (11) : 982 - 985
  • [5] A quick flow cytometry protocol to assess Helicobacter pylori viability and density
    Alba, C.
    Marin, A. C.
    McNicholl, A. G.
    Montalban-Arques, A.
    Garcia-Fresnadillo, D.
    Gisbert, J. P.
    Alarcon, T.
    Bernardo, D.
    HELICOBACTER, 2018, 23
  • [6] Flow cytometry analysis of Nosema species to assess spore viability and longevity
    J. G. Sánchez Collado
    M. Higes
    L. Barrio
    R. Martín-Hernández
    Parasitology Research, 2014, 113 : 1695 - 1701
  • [7] Flow cytometry analysis of Nosema species to assess spore viability and longevity
    Sanchez Collado, J. G.
    Higes, M.
    Barrio, L.
    Martin-Hernandez, R.
    PARASITOLOGY RESEARCH, 2014, 113 (05) : 1695 - 1701
  • [8] Design of multicolor panels in flow cytometry
    Barteneva, Natasha
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2012, 82B (04) : O2 - O2
  • [9] Tracking defined microbial communities by multicolor flow cytometry reveals tradeoffs between productivity and diversity
    Midani, Firas S.
    David, Lawrence A.
    FRONTIERS IN MICROBIOLOGY, 2023, 13
  • [10] Evaluation of flow cytometry to assess Erwinia amylovora viability under different stress conditions
    Santander, R. D.
    Catala-Senent, J. F.
    Ordax, M.
    Flores, A.
    Marco-Noales, E.
    Biosca, E. G.
    MICROORGANISMS IN INDUSTRY AND ENVIRONMENT: FROM SCIENTIFIC AND INDUSTRIAL RESEARCH TO CONSUMER PRODUCTS, 2011, : 51 - 54