Estimation of the radon dose in buildings by measuring the exhalation rate from building materials

被引:6
|
作者
Steiner, V [1 ]
Kovler, K [1 ]
Perevalov, A [1 ]
Kelm, H [1 ]
机构
[1] Minist Environm, Div Radiat & Noise, Jerusalem, Israel
关键词
radon; exhalation; building material; radiation dose; detectors; radon sampler; charcoal; electret;
D O I
10.1016/j.ics.2004.11.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The indoor radon radiation dose in buildings may be estimated by measuring the radon exhalation rate from the walls. We show that the classical accumulator method produces the same results with either passive or active radon detectors. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:397 / 398
页数:2
相关论文
共 50 条
  • [1] RADON EXHALATION RATE IN BUILDING-MATERIALS
    RAWAT, A
    JOJO, PJ
    KHAN, AJ
    TYAGI, RK
    PRASAD, R
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 391 - 394
  • [2] RADON EXHALATION RATE FROM VARIOUS BUILDING-MATERIALS
    CHEN, CJ
    WENG, PS
    CHU, TC
    HEALTH PHYSICS, 1993, 64 (06): : 613 - 619
  • [3] SIMPLE METHOD FOR MEASURING THE RADON DIFFUSION-COEFFICIENT AND EXHALATION RATE FROM BUILDING-MATERIALS
    STRANDEN, E
    HEALTH PHYSICS, 1979, 37 (02): : 242 - 244
  • [4] MEASUREMENT OF RADON EXHALATION RATE FROM SOME BUILDING-MATERIALS
    KHAN, AJ
    PRASAD, R
    TYAGI, RK
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (04): : 609 - 610
  • [5] Measuring the real radon exhalation from walls in buildings
    Di Carlo, C.
    Maiorana, A.
    Ampollini, M.
    Antignani, S.
    Caprio, M.
    Carpentieri, C.
    Dante, V.
    Petetti, E.
    Bochicchio, F.
    MEASUREMENT, 2025, 242
  • [6] ESTIMATION OF DOSE-RATE FOR INDOOR RADON FROM BUILDING-MATERIALS
    KHAN, AJ
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1994, 33 (01) : 81 - 84
  • [7] Study on a new charcoal closed chamber method for measuring radon exhalation rate of building materials
    Song Yanchao
    Wang Junlin
    Shang Bing
    Cui Hongxing
    Wu Yunyun
    RADIATION MEASUREMENTS, 2020, 134
  • [8] The effects of typical wall covers on the radon exhalation rate from building materials
    Savidou, A
    Kritidis, P
    Raptis, C
    Mihaleas, S
    FRESENIUS ENVIRONMENTAL BULLETIN, 1996, 5 (11-12): : 667 - 675
  • [9] Radon and thoron exhalation rate measurements from building materials used in Serbia
    Celikovic, Igor T.
    Pantelic, Gordana K.
    Zivanovic, Milos Z.
    Vukanac, Ivana S.
    Nikolic, Jelena D. Krneta
    Kandic, Aleksandar B.
    Loncar, Boris B.
    NUKLEONIKA, 2020, 65 (02) : 111 - 114
  • [10] Simultaneous measurement of radon and thoron exhalation rate from soil and building materials
    Cosma, C
    Cozar, O
    Jurcut, T
    Baciu, C
    Pop, I
    NATURAL RADIATION ENVIRONMENT VII, 2005, 7 : 699 - 705