Amperometric biosensors based on deposition of gold and platinum nanoparticles on polyvinylferrocene modified electrode for xanthine detection

被引:28
|
作者
Bas, Salih Zeki [1 ]
Gulce, Handan [2 ]
Yildiz, Salih [1 ]
Gulce, Ahmet [2 ]
机构
[1] Selcuk Univ, Dept Chem, Konya, Turkey
[2] Selcuk Univ, Dept Chem Engn, Konya, Turkey
关键词
Amperometric biosensor; Xanthine oxidase; Xanthine detection; Gold deposition; Platinum deposition; Polyvinylferrocene; URIC-ACID; LIQUID-CHROMATOGRAPHY; ENZYME ELECTRODE; HYPOXANTHINE; OXIDASE; PERFORMANCE; FILM; QUANTIFICATION; ALLANTOIN; SERUM;
D O I
10.1016/j.talanta.2011.09.060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, new xanthine biosensors, XO/Au/PVF/Pt and XO/Pt/PVF/Pt, based on electroless deposition of gold(Au) and platinum(Pt) nanoparticles on polyvinylferrocene(PVF) coated Pt electrode for detection of xanthine were presented. The amperometric responses of the enzyme electrodes were measured at the constant potential, which was due to the electrooxidation of enzymatically produced H2O2. Compared with XO/PVF/Pt electrode, XO/Au/PVF/Pt and XO/Pt/PVF/Pt exhibited excellent electrocatalytic activity towards the oxidation of the analyte. Effect of Au and Pt nanoparticles was investigated by monitoring the response currents at the different deposition times and the different concentrations of KAuCl4 and PtBr2. Under the optimal conditions, the calibration curves of XO/Au/PVF/Pt and XO/Pt/PVF/Pt were obtained over the range of 2.5 x 10(-3) to 0.56 mM and 2.0 x 10(-3) to 0.66 mM, respectively. The detection limits were 7.5 x 10(-4) mM for XO/Au/PVF/Pt and 6.0 x 10(-4) mM for XO/Pt/PVF/Pt. The effects of interferents, the operational and the storage stabilities of the biosensors and the applicabilities of the proposed biosensors to the drug samples analysis were also evaluated. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:189 / 196
页数:8
相关论文
共 50 条
  • [1] Amperometric xanthine biosensors based on electrodeposition of platinum on polyvinylferrocenium coated Pt electrode
    Bas, Salih Zeld
    Gulce, Handan
    Yildiz, Salih
    [J]. JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2011, 72 (3-4) : 282 - 288
  • [2] Amperometric biosensor based on immobilized acetylcholinesterase on gold nanoparticles and silk fibroin modified platinum electrode for detection of methyl paraoxon, carbofuran and phoxim
    Yin, Huanshun
    Ai, Shiyun
    Xu, Jing
    Shi, Weijie
    Zhu, Lusheng
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 637 (1-2) : 21 - 27
  • [3] Simple hemoglobin-gold nanoparticles modified electrode for the amperometric detection of acrylamide
    Garabagiu, Sorina
    Mihailescu, Gheorghe
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 659 (02) : 196 - 200
  • [4] Amperometric glucose biosensor based on gold-deposited polyvinylferrocene film on Pt electrode
    Sulak, MT
    Gökdogan, Ö
    Gülce, A
    Gülce, H
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 21 (09): : 1719 - 1726
  • [5] MODIFIED ELECTRODE SURFACE IN AMPEROMETRIC BIOSENSORS
    BARTLETT, PN
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (03) : B10 - B17
  • [6] Amperometric biosensor for nitrite and hydrogen peroxide based on hemoglobin immobilized on gold nanoparticles/polythionine/platinum nanoparticles modified glassy carbon electrode
    Zhang, Yu
    Yuan, Ruo
    Chai, Yaqin
    Wang, Jinfen
    Zhong, Huaan
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2012, 87 (04) : 570 - 574
  • [7] Amperometric Biosensors for Tyramine Determination Based on Graphene Oxide and Polyvinylferrocene Modified Screen-printed Electrodes
    Erden, Pinar Esra
    Erdogan, Zehra Ozden
    Ozturk, Funda
    Kocoglu, Irem Okman
    Kilic, Esma
    [J]. ELECTROANALYSIS, 2019, 31 (12) : 2368 - 2378
  • [8] Polyvinylferrocenium based platinum electrodeposited amperometric biosensors for lysine detection
    Sahin, Ozlem Gokdogan
    Gulce, Handan
    Gulce, Ahmet
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 690 : 1 - 7
  • [9] A method for determination of xanthine in meat by amperometric biosensor based on silver nanoparticles/cysteine modified Au electrode
    Devi, Rooma
    Batra, Bhawna
    Lata, Suman
    Yadav, Sandeep
    Pundir, C. S.
    [J]. PROCESS BIOCHEMISTRY, 2013, 48 (02) : 242 - 249
  • [10] Electrocatalytic Behavior and Amperometric Detection of Morphine on ITO Electrode Modified with Directly Electrodeposited Gold Nanoparticles
    Zhao, Yanrong
    Wu, Ying
    Zhang, Yu
    Chen, Zeguan
    Cao, Xia
    Di, Junwei
    Yang, Jianping