FRENCH POPULATION EXPOSURE TO IONIZING RADIATION FROM DIAGNOSTIC MEDICAL PROCEDURES IN 2007

被引:13
|
作者
Etard, Cecile [1 ]
Sinno-Tellier, Sandra [2 ]
Empereur-Bissonnet, Pascal [2 ]
Aubert, Bernard [1 ]
机构
[1] Inst Radioprotect & Surete Nucl, Unite Expertise Radioprotect Med, F-92262 Fontenay Aux Roses, France
[2] Inst Veille Sanit, F-94415 St Maurice, France
来源
HEALTH PHYSICS | 2012年 / 102卷 / 06期
关键词
computed tomography; diagnostic radiology; dose; population; effective dose;
D O I
10.1097/HP.0b013e318244154a
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study was to update the 2002 data on medical exposure of the French population to ionizing radiation. It is based on 2007 data and only includes exposures from diagnostic procedures: conventional radiology, computed tomography, nuclear medicine, and diagnostic interventional radiology. Relevant data concerning the nature and frequencies of the examinations were obtained from two main sources: the national health insurance data for private practice and representative surveys in public hospitals for public practice. An "average" effective dose was assessed for each type of examination using principally dosimetric data collected to update the French diagnostic reference levels and professional guidance. The results showed that 74.6 million examinations were performed in 2007, leading to an average effective dose per inhabitant equal to 1.3 mSv per year. Conventional radiology and CT represented 63% and 10.1% of the examinations and 26.1% and 58.0% of the effective dose, respectively. The annual number of examinations per inhabitant was constant between 2002 and 2007 (about 1.2 examinations). However, the corresponding average effective dose per inhabitant increased by 57%, from 0.83 to 1.3 mSv per year. This increased dose was due mostly to a growing number of CT and nuclear medicine examinations. As recommended by the European Commission, studies should be conducted every 5 y to survey the evolution of medical exposure of the French population. Furthermore, specific studies should be conducted to evaluate whether this estimated increase in dose delivered for diagnostics is related to an increase in the medical benefit. Health Phys. 102(6):670-679;2012
引用
收藏
页码:670 / 679
页数:10
相关论文
共 50 条
  • [1] Exposure of the French population to ionizing radiations from medical diagnostic procedures in 2012
    Dreuil, S.
    Etard, C.
    [J]. RADIOPROTECTION, 2017, 52 (01) : 45 - 49
  • [2] Exposure of the French paediatric population to ionising radiation from diagnostic medical procedures in 2010
    Etard, Cecile
    Aubert, Bernard
    Mezzarobba, Myriam
    Bernier, Marie-Odile
    [J]. PEDIATRIC RADIOLOGY, 2014, 44 (12) : 1588 - 1594
  • [3] Exposure of the French paediatric population to ionising radiation from diagnostic medical procedures in 2010
    Cécile Etard
    Bernard Aubert
    Myriam Mezzarobba
    Marie-Odile Bernier
    [J]. Pediatric Radiology, 2014, 44 : 1588 - 1594
  • [4] RADIATION EXPOSURE OF THE POPULATION IN THE USSR DUE TO MEDICAL DIAGNOSTIC PROCEDURES
    VOROBJEV, EI
    STAVITSKY, RV
    KNIZNIKOV, VA
    BARKCHUDAROV, RM
    KORSUNSKY, VN
    POPOV, VI
    TARASENKO, JT
    POSTNIKOV, VA
    FROLOV, NV
    SIDORIN, VP
    [J]. RADIATION PROTECTION DOSIMETRY, 1985, 11 (01) : 35 - 40
  • [5] Medical exposure of the population from diagnostic use of ionizing radiation in Luxembourg between 1994 and 2002
    Shannoun, Ferid
    Zeeb, Hajo
    Back, Carlo
    Blettner, Maria
    [J]. HEALTH PHYSICS, 2006, 91 (02): : 154 - 162
  • [6] Population exposure to ionizing radiation from medical examinations in France
    Scanff, P.
    Donadieu, J.
    Pirard, P.
    Aubert, B.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (963): : 204 - 213
  • [7] Cumulative Exposure to Ionizing Radiation From Diagnostic and Therapeutic Cardiac Imaging Procedures
    Chen, Jersey
    Einstein, Andrew J.
    Fazel, Reza
    Krumholz, Harlan M.
    Wang, Yongfei
    Ross, Joseph S.
    Ting, Henry H.
    Shah, Nilay D.
    Nasir, Khurram
    Nallamothu, Brahmajee K.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (09) : 702 - 711
  • [8] Potentially Harmful Ionizing Radiation Exposure from Diagnostic Tests and Medical Procedures in Patients with Aneurysmal Subarachnoid Hemorrhage
    Bacon, J. David
    Slade, Emily
    Smith, Austin L.
    Allareddy, Greeshma
    Duan, Ran
    Fraser, Justin F.
    Hatton, Kevin W.
    [J]. WORLD NEUROSURGERY, 2020, 140 : E153 - E160
  • [9] Population exposure to diagnostic use of ionizing radiation in the Netherlands
    Brugmans, MJP
    Buijs, WCAM
    Geleijns, J
    Lembrechts, J
    [J]. HEALTH PHYSICS, 2002, 82 (04): : 500 - 509
  • [10] Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures.
    Fazel, Reza
    Krumholz, Harlan M.
    Wang, Yongfei
    Ross, Joseph S.
    Chen, Jersey
    Ting, Henry H.
    Shah, Nilay D.
    Nasir, Khurram
    Einstein, Andrew J.
    Nallamothu, Brahmajee K.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (09): : 849 - 857