Effects of Varying Matching Between Collimator Hole and Scintillator Pixel on Gamma Camera Image Resolution

被引:1
|
作者
Kim, Minho [1 ,2 ]
Bae, Jae Keon [1 ]
Kim, Kyeong Min [1 ]
Lee, Wonho [3 ]
机构
[1] Korea Inst Radiol & Med Sci, Div Med Radiat Equipment, Seoul 01812, South Korea
[2] Korea Univ, Dept Bioconvergence Engn, Seoul 02841, South Korea
[3] Korea Univ, Sch Hlth & Environm Sci, Seoul 02841, South Korea
关键词
Gamma camera; Pixelated scintillator; Parallel hole collimator; Monte Carlo simulation; Spatial resolution; MYOCARDIAL-PERFUSION; HIGH-SENSITIVITY; SPECT; SYSTEM; DESIGN; VALIDATION; DETECTORS; COMPACT;
D O I
10.3938/jkps.72.455
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A collimator is a key component of gamma cameras, which affects imaging performance significantly. Recently, pixelated scintillator arrays are widely applied in the development of highresolution gamma cameras, instead of monolithic scintillator blocks. Therefore, combining the collimator and the pixelated scintillator has been a crucial factor in achieving good imaging performance. In this study, we investigated the effects of the shape and position of a collimator hole on the image resolution of a gamma camera with a pixelated scintillator. We designed a pixel-matched collimator and a low-energy high-resolution (LEHR) collimator with hexagonal shaped holes that have the same collimator geometrical efficiency. Simulation experiments were performed with a Monte Carlo simulation package (GATE v7.0). For both types of collimator, camera sensitivity was measured for validating the collimator efficiency, and planar images were obtained to measure spatial resolution, with changing the line profile angle based on the septa direction. Camera sensitivities for both collimators were equivalent (difference = 1.76 +/- 0.51%). In contrast to the case of the pixel-matched collimator, in the case of the LEHR collimator, as the angle of the line profile varied, the spatial resolution showed a difference at each profile angle. In the case when two collimator holes symmetrically matched with one scintillator pixel, the spatial resolution showed a 64.87% difference in its maximum and a position distortion of 26.06% from the original source position, according to the profile angle, compared to the other unmatched cases. These results showed that using a pixel-matched collimator in gamma camera systems employing a pixelated scintillator is essential for the exact delineation of small regions using high resolution gamma camera imaging.
引用
收藏
页码:455 / 461
页数:7
相关论文
共 50 条
  • [1] Effects of Varying Matching Between Collimator Hole and Scintillator Pixel on Gamma Camera Image Resolution
    Minho Kim
    Jae Keon Bae
    Kyeong Min Kim
    Wonho Lee
    Journal of the Korean Physical Society, 2018, 72 : 455 - 461
  • [3] A compact gamma camera with scintillation array and parallel-hole collimator
    Zhu Jie
    Ma Hongguang
    Ma Wenyan
    Zeng Hui
    Wang Zhaomin
    Xu Zizhong
    NUCLEAR SCIENCE AND TECHNIQUES, 2008, 19 (05) : 297 - 301
  • [4] Improving gamma camera imaging using parallel jagged hole collimator
    Moslemi, Vahid
    Shapiro, Boris
    Van Mullekom, Pieter
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [5] A novel parallel hole collimator for high resolution SPET imaging with a compact LaBr3 gamma camera
    Pani, R.
    Pellegrini, R.
    Bennati, P.
    Cinti, M. N.
    Ridolfi, S.
    Scafe, R.
    De Vincentis, G.
    Lo Meo, S.
    Lanconelli, N.
    Navarria, F.
    Moschini, G.
    Fabbri, A.
    D'Abramo, E.
    Sacco, D.
    Cencelli, V. Orsolini
    De Notaristefani, F.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3099 - +
  • [6] The high resolution scintillator type X-ray imaging detector with Si pixel collimator
    Tabata, Kento
    Ohtake, Ryota
    Koike, Akifumi
    Aoki, Toru
    FOURTEENTH INTERNATIONAL CONFERENCE ON CORRELATION OPTICS, 2020, 11369
  • [7] Gamma-ray imaging using a CdZnTe pixel array and a high-resolution, parallel-hole collimator
    Kastis, GA
    Barber, HB
    Barrett, HH
    Balzer, SJ
    Lu, D
    Marks, DG
    Stevenson, G
    Woolfenden, JM
    Appleby, M
    Tueller, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 1923 - 1927
  • [8] Assessment of the axial resolution of a compact gamma camera with coded aperture collimator
    Meissner, Tobias
    Cerbone, Laura Antonia
    Russo, Paolo
    Nahm, Werner
    Hesser, Juergen
    EJNMMI PHYSICS, 2024, 11 (01)
  • [9] Method to Improve Angular Resolution of Portable Gamma Camera with Pinhole Collimator
    Potapov, Victor N.
    Ivanov, Oleg P.
    Semin, Iliya A.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [10] Optimization of a parallel hole collimator/CdZnTe gamma-camera architecture for scintimammography
    Robert, Charlotte
    Montemont, Guillaume
    Rebuffel, Veronique
    Verger, Loick
    Buvat, Irene