Dosimetric comparison of Helical Tomotherapy and Gamma Knife Stereotactic Radiosurgery for single brain metastasis

被引:30
|
作者
Penagaricano, Jose A. [1 ]
Yan, Yulong [1 ]
Shi, Chengyu [2 ]
Linskey, Mark E. [3 ]
Ratanatharathorn, Vaneerat [1 ]
机构
[1] Univ Arkansas Med Sci, Little Rock, AR 72205 USA
[2] Canc Therapy & Res Ctr S Texas, San Antonio, TX 78229 USA
[3] Univ Calif, Irvine Med Ctr, Dept Neurol Surg, Orange, CA 92868 USA
关键词
D O I
10.1186/1748-717X-1-26
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Helical Tomotherapy (HT) integrates linear accelerator and computerized tomography (CT) technology to deliver IMRT. Targets are localized (i.e. outlined as gross tumor volume [GTV] and planning target volume [PTV]) on the planning kVCT study while daily MVCT is used for correction of patient's set-up and assessment of inter-fraction anatomy changes. Based on dosimetric comparisons, this study aims to find dosimetric equivalency between single fraction HT and Gamma Knife (R) stereotactic radiosurgery (GKSRS) for the treatment of single brain metastasis. Methods: The targeting MRI data set from the GKSRS were used for tomotherapy planning. Five patients with single brain metastasis treated with GKSRS were re-planned in the HT planning station using the same prescribed doses. There was no expansion of the GTV to create the PTV. Sub-volumes were created within the PTV and prescribed to the maximum dose seen in the GKSRS plans to imitate the hot spot normally seen in GKSRS. The PTV objective was set as a region at risk in HT planning using the same prescribed dose to the PTV periphery as seen in the corresponding GKSRS plan. The tumor volumes ranged from 437-1840 mm(3). Results: Conformality indices are inconsistent between HT and GKSRS. HT generally shows larger lower isodose line volumes, has longer treatment time than GKSRS and can treat a much larger lesion than GKSRS. Both HT and GKSRS single fraction dose-volume toxicity may be prohibitive in treating single or multiple lesions depending on the number and the sizes of the lesions. Conclusion: Based on the trend for larger lower dose volumes and more constricted higher dose volumes in HT as compared to GKSRS, dosimetric equivalency was not reached between HT and GKSRS.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Dosimetric comparison of Helical Tomotherapy and Gamma Knife Stereotactic Radiosurgery for single brain metastasis
    José A Peñagarícano
    Yulong Yan
    Chengyu Shi
    Mark E Linskey
    Vaneerat Ratanatharathorn
    [J]. Radiation Oncology, 1
  • [2] Helical tomotherapy versus stereotactic gamma knife radiosurgery for single and multiple brain tumors: A dosimetric comparison
    Kumar, T.
    Rakowski, J.
    Alkhafazi, M.
    Zhao, B.
    Tammy, A.
    Burmeister, J.
    Vlachaki, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S533 - S533
  • [3] Helical TomoTherapy versus sterotactic Gamma Knife radiosurgery in the treatment of single and multiple brain tumors: a dosimetric comparison
    Kumar, Tushar
    Rakowski, Joseph
    Zhao, Bo
    Alkhafaji, Mazin
    Burmeister, Jacob
    Austin, Tammy
    Vlachaki, Maria
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (04): : 27 - 41
  • [4] Dosimetric comparison of ZAP-X, Gamma Knife, and CyberKnife stereotactic radiosurgery for single brain metastasis
    Wang, Jinyuan
    Zheng, Qingzeng
    Wang, Yanping
    Wang, Chengcheng
    Xu, Shouping
    Ju, Zhongjian
    Pan, Longsheng
    Bai, Jingmin
    Liu, Yunmo
    Qu, Baolin
    Dai, Xiangkun
    [J]. BMC CANCER, 2024, 24 (01)
  • [5] GAMMA KNIFE STEREOTACTIC RADIOSURGERY FOR BRAIN METASTASIS
    Kusak, M. E.
    Martinez, N.
    Gutierrez, J.
    Rey, G.
    Martinez, R.
    [J]. NEURO-ONCOLOGY, 2008, 10 (06) : 1116 - 1116
  • [6] Dosimetric comparison of helical tomotherapy and stereotactic radiotherapy for single brain lesions
    Reinartz, G.
    Ernst, I
    Willich, N.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 35 - 35
  • [7] Dosimetric comparison between Tomotherapy and Cyberknife for radiosurgery of single brain metastasis
    Greto, D.
    Pallotta, S.
    Masi, L.
    Talamonti, C.
    Doro, R.
    Scoccianti, S.
    Marrazzo, L.
    Meattini, I.
    Bonomo, P.
    Livi, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S138 - S138
  • [8] Dosimetric comparison of inverse and forward planning for Gamma Knife stereotactic radiosurgery of brain metastases
    Xu, Qianyi
    Luo, Dershan
    Mulvihill, David
    Goldman, Warren
    Turtz, Alan
    Kubicek, Gregory J.
    [J]. MEDICAL DOSIMETRY, 2020, 45 (04) : 317 - 320
  • [9] A dosimetric comparison of five brain tumor treatment plans for treatment with helical Tomotherapy and Gamma Knife
    Grossheim, Linda
    Jursinic, Paul
    [J]. NEURO-ONCOLOGY, 2007, 9 (04) : 583 - 583
  • [10] Dosimetric comparison of large field widths in helical tomotherapy for intracranial stereotactic radiosurgery
    Watcharawipha, A.
    Chitapanarux, I.
    Jia-Mahasap, B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (03): : 701 - 707