Complete acetabular cup revision versus isolated liner exchange for polyethylene wear and osteolysis without loosening in cementless total hip arthroplasty

被引:20
|
作者
Koh, Kyoung Hwan [1 ]
Moon, Young-Wan [1 ]
Lim, Seung-Jae [1 ]
Lee, Hyun Il [1 ]
Shim, Jae Woo [1 ]
Park, Youn-Soo [1 ]
机构
[1] Sungkyunkwan Univ, Dept Orthopaed Surg, Samsung Med Ctr, Sch Med, 50 Ilwon Dong, Seoul 135710, South Korea
关键词
Total hip replacement arthroplasty; Revision; Complete acetabular cup revision; Isolated liner change; Re-revision surgery; PELVIC OSTEOLYSIS; COMPONENTS; MANAGEMENT; CEMENTATION;
D O I
10.1007/s00402-011-1338-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Revision surgery in patients showing polyethylene wear and acetabular osteolysis without visible acetabular cup loosening involves the difficult decision of whether to revise only the liner or both the cup and the liner. The purpose of this study is to compare the outcomes of complete acetabular revision and isolated liner exchange in patients showing wear and osteolysis without loosening. We evaluated 80 cases of revision surgery for polyethylene wear and osteolysis without cup loosening performed between October 1997 and December 2008. The cup revision group consisted of 45 patients who underwent a complete acetabular cup replacement, and the cup retention group consisted of 35 patients who underwent either an isolated liner exchange or a liner cementing procedure. Comparisons between the two groups were performed. There were differences in femoral stem revision, estimated blood loss, and hospital stay. Other variables including complications, osteolysis progression, re-revision rate, clinical score, and satisfaction showed no differences between the two groups. There was one case of early loosening and subsequent re-revision surgery in the cup revision group, as well as one case of wear progression and liner dislodgement leading to complete re-revision of the acetabular component and femoral stem in the cup retention group. We found no differences in acetabular osteolysis progression, fixation failure, or complication between the cup revision and retention groups. Therefore, isolated liner exchange without cup extraction in cases of osteolysis that includes a well-fixed and well-positioned shell could be considered as a viable treatment option.
引用
收藏
页码:1591 / 1600
页数:10
相关论文
共 50 条
  • [1] Complete acetabular cup revision versus isolated liner exchange for polyethylene wear and osteolysis without loosening in cementless total hip arthroplasty
    Kyoung Hwan Koh
    Young-Wan Moon
    Seung-Jae Lim
    Hyun Il Lee
    Jae Woo Shim
    Youn-Soo Park
    [J]. Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1591 - 1600
  • [2] Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty
    Sochart, DH
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (363) : 135 - 150
  • [3] Acetabular revision for aseptic loosening in total hip arthroplasty using cementless cup and impacted morselized allograft
    Parratte, S.
    Argenson, J.-N.
    Flecher, X.
    Aubaniac, J.-M.
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (03): : 255 - 263
  • [4] Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty
    Young, AM
    Sychterz, CJ
    Hopper, RH
    Engh, CA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01): : 58 - 63
  • [5] Isolated Polyethylene Exchange versus Acetabular Revision for Polyethylene Wear
    Restrepo, Camilo
    Ghanem, Elie
    Houssock, Carrie
    Austin, Mathew
    Parvizi, Javad
    Hozack, William J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) : 194 - 198
  • [6] Revision total hip arthroplasty for pelvic osteolysis with well-fixed cementless cup
    Chang, Jun-Dong
    Yoo, Je-Hyun
    Hur, Mina
    Lee, Sang-Soo
    Chung, Yung-Khee
    Lee, Chang-Ju
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (07): : 987 - 992
  • [7] ARE CEMENTLESS ACETABULAR COMPONENTS THE CAUSE OF EXCESS WEAR AND OSTEOLYSIS IN TOTAL HIP-ARTHROPLASTY
    NASHED, RS
    BECKER, DA
    GUSTILO, RB
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 19 - 28
  • [8] Outcomes of isolated head-liner exchange versus full acetabular component revision in aseptic revision total hip arthroplasty
    Berlinberg, Elyse J.
    Roof, Mackenzie A.
    Meftah, Morteza
    Long, William J.
    Schwarzkopf, Ran
    [J]. HIP INTERNATIONAL, 2023, 33 (04) : 716 - 726
  • [9] Cementless total hip arthroplasty with a threaded acetabular cup
    Fernandez-Gonzalez, J
    Sevillano, RC
    Garcia-Araujo, C
    [J]. INTERNATIONAL ORTHOPAEDICS, 1997, 21 (05) : 327 - 331
  • [10] Cementless total hip arthroplasty with a threaded acetabular cup
    J. Fernández-González
    R. Canosa Sevillano
    C. García-Araujo
    [J]. International Orthopaedics, 1997, 21 : 327 - 331