Influence of cardiac stress protocol on myocardial perfusion imaging accuracy: The role of exercise level on the evaluation of ischemic burden

被引:12
|
作者
Gimelli, Alessia [1 ]
Liga, Riccardo [2 ]
Pasanisi, Emilio Maria [1 ]
Casagranda, Mirta [1 ]
Coceani, Michele [1 ]
Marzullo, Paolo [1 ,3 ]
机构
[1] Fdn Toscana Gabriele Monasterio, I-56124 Pisa, Italy
[2] Univ Hosp Pisa, Cardiothorac & Vasc Dept, Pisa, Italy
[3] CNR, Inst Clin Physiol, Pisa, Italy
关键词
Myocardial perfusion imaging; ischemic heart disease; exercise stress test; pharmacological stress test; CZT; CORONARY-ARTERY-DISEASE; EMISSION COMPUTED-TOMOGRAPHY; LOW-RISK; METAANALYSIS; IMPACT; CAMERA; SPECT;
D O I
10.1007/s12350-015-0101-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Some specifics of cardiac stress protocols, i.e., stressor used or exercise level achieved, may impact myocardial perfusion imaging (MPI) accuracy. Four-hundred and seventy-five patients were submitted to MPI and coronary angiography. MPI was performed after exercise (303 patients) or dipyridamole stress (172 patients). A coronary stenosis aeyen70% was considered significant. In case of exercise test, a peak heart rate (HR) < 85% of the maximal age predicted was considered submaximal and categorized as follows: > 75% and < 85% ("Group 1"); < 75% ("Group 2"). At coronary angiography, 312/475 (66%) patients showed significant stenosis. In the overall population, MPI showed a high accuracy in unmasking significant coronary stenosis, independently of the stress protocol adopted (AUC .76 for exercise vs .78 for vasodilator; P = NS). However, in case of an exercise stress test, a significant interaction between peak %HR and MPI diagnostic power was evident. While an elevated accuracy was still maintained in "Group 1" patients (AUC .79; P vs maximal exercise = NS), a significant drop was demonstrated in "Group 2" patients (AUC .66; P vs maximal exercise = .012, and P vs "Group 1" = .042). The accuracy of MPI is not influenced by the stress protocol adopted. Exercise MPI maintains an elevated accuracy as long as the %HR remains > 75%.
引用
收藏
页码:1114 / 1122
页数:9
相关论文
共 50 条
  • [1] Influence of cardiac stress protocol on myocardial perfusion imaging accuracy: The role of exercise level on the evaluation of ischemic burden
    Alessia Gimelli
    Riccardo Liga
    Emilio Maria Pasanisi
    Mirta Casagranda
    Michele Coceani
    Paolo Marzullo
    Journal of Nuclear Cardiology, 2016, 23 : 1114 - 1122
  • [2] Stress Protocol and Myocardial Perfusion Imaging Accuracy
    Alessia Gimelli
    Riccardo Liga
    Current Cardiovascular Imaging Reports, 2019, 12
  • [3] Stress Protocol and Myocardial Perfusion Imaging Accuracy
    Gimelli, Alessia
    Liga, Riccardo
    CURRENT CARDIOVASCULAR IMAGING REPORTS, 2019, 12 (01)
  • [4] Combined Adenosine and Low-level Exercise Stress Protocol, AdenoEx, for Myocardial Perfusion Imaging
    Jimenez-Heffernan, A.
    Sanchez, C.
    Sanchez de Mora, E.
    Delgado, J.
    Salgado, C.
    Lopez, R.
    Lopez, J.
    Prado, B.
    Roa, J.
    Martinez, B.
    Diaz, J.
    Tobaruela, A.
    Paz, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S285 - S285
  • [5] Evaluation of ischaemia in patients with atrial fibrillation: impact of stress protocol on myocardial perfusion imaging accuracy
    Gimelli, Alessia
    Liga, Riccardo
    Startari, Umberto
    Giorgetti, Assuero
    Pieraccini, Laura
    Marzullo, Paolo
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (07) : 781 - 787
  • [6] Stress Cardiac MR Imaging: The Role of Stress Functional Assessment and Perfusion Imaging in the Evaluation of Ischemic Heart Disease
    Al Sayari, Saeed
    Kopp, Sebastien
    Bremerich, Jens
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2015, 53 (02) : 355 - +
  • [7] Stress protocol and accuracy of myocardial perfusion imaging: Is it better to start from the end?
    Marco Spadafora
    Marco Salvatore
    Alberto Cuocolo
    Journal of Nuclear Cardiology, 2016, 23 : 1123 - 1127
  • [8] Stress protocol and accuracy of myocardial perfusion imaging: Is it better to start from the end?
    Spadafora, Marco
    Salvatore, Marco
    Cuocolo, Alberto
    JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (05) : 1123 - 1127
  • [9] Safety, tolerability and accuracy of adenosine combined with maximal exercise protocol in myocardial perfusion imaging
    Ferrer-Antunes, A.
    Oliveira, L.
    Correia, J.
    Rovira, E.
    Ferreira, P.
    Ferreira, M.
    Providencia, L.
    Lima, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S92 - S92
  • [10] Scar burden by myocardial perfusion imaging predicts echocardiographic response to cardiac resynchronization therapy in ischemic cardiomyopathy
    Adelstein, Evan C.
    Saba, Samir
    AMERICAN HEART JOURNAL, 2007, 153 (01) : 105 - 112