Subfascial expansive plasty for intrathecal baclofen pump replacement. A technical note

被引:0
|
作者
Pancucci, Giovanni [1 ]
Perez-Prat, Gustau [1 ]
Rivero-Garvia, Monica [1 ]
Jose Mayorga-Buiza, Maria [1 ]
Marquez-Rivas, Javier [1 ]
机构
[1] Univ Hosp Virgen del Rocio, Neurosurg Dept, Seville, Spain
来源
JOURNAL OF SPINAL CORD MEDICINE | 2016年 / 39卷 / 01期
关键词
Intrathecal injection; Baclofen; Muscle spasticity; THERAPY;
D O I
10.1179/2045772315Y.0000000019
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose: Although intratechal pump replacement is a common technique, it can be sometimes complicated when aiming to replace a 20 ml pump with a bigger one (40 ml). We developed a simple and straightforward technique to relax the wall of the pocket of the pump, preserving its fascial layer. Methods: A 20-year-old boy with spastic tetraparesia was admitted for pump replacement. After scar opening and pump removal, various lineal incisions were performed in the posterior layer of the subfascial pocket in a cranio-caudal direction. Results: A 40 ml pump was placed without skin incision ampliation and preserving subfascial plane. Conclusions: This easy, expansive technique for infusion pump replacement preserves subfascial plane and prevents the need for more extensive surgeries.
引用
收藏
页码:118 / 120
页数:3
相关论文
共 15 条
  • [1] Subfascial implantation of intrathecal baclofen pumps in children: Technical note
    Kopell, BH
    Sala, D
    Doyle, WK
    Feldman, DS
    Wisoff, JH
    Weiner, HL
    NEUROSURGERY, 2001, 49 (03) : 753 - 756
  • [2] Subfascial implantation of intrathecal baclofen pumps in children: Technical note - Comments
    Drake, JM
    Steinbok, P
    Albright, AL
    Sutton, LN
    NEUROSURGERY, 2001, 49 (03) : 756 - 757
  • [3] A Novel Skin and Fascia Opening for Subfascial Inserting of Intrathecal Baclofen Pump
    Fiaschi, Pietro
    Cama, Armando
    Piatelli, Gianluca
    Moretti, Paolo
    Pavanello, Marco
    WORLD NEUROSURGERY, 2018, 110 : 244 - 248
  • [4] Baclofen withdrawal following removal of an intrathecal baclofen pump despite oral baclofen replacement
    Greenberg, MI
    Hendrickson, RG
    JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 2003, 41 (01): : 85 - 87
  • [5] Image-guided intrathecal baclofen pump catheter implantation: a technical note and case series
    Robinson, Shenandoah
    Robertson, Faith C.
    Dasenbrock, Hormuzdiyar H.
    O'Brien, Cormac P.
    Berde, Charles
    Padua, Horacio
    JOURNAL OF NEUROSURGERY-SPINE, 2017, 26 (05) : 621 - 627
  • [6] Comment on "baclofen withdrawal following removal of an intrathecal baclofen pump despite oral baclofen replacement"
    Coffey, RJ
    Ridgely, PM
    JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 2003, 41 (07): : 1043 - 1043
  • [7] Posterior cervical approach for intrathecal baclofen pump insertion in children with previous spinal fusions - Technical note
    Liu, JK
    Walker, ML
    JOURNAL OF NEUROSURGERY, 2005, 102 (01) : 119 - 122
  • [8] Intrathecal baclofen therapy. Overdose during replacement of a medication pump
    Kramer, K.
    Weber, M.
    Koulousakis, A.
    Lier, H.
    Krep, H.
    ANAESTHESIST, 2009, 58 (09): : 891 - 896
  • [9] Intrathecal baclofen therapy-how we do it Technical note
    Ammar, Amr
    Ughratdar, Ismail
    Sivakumar, Gnanamurthy
    Vloeberghs, Michael H.
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2012, 10 (05) : 439 - 444
  • [10] Mandibular Notch Contouring in Temporomandibular Joint Replacement. Technical Note
    Olate, Sergio
    Ravelo, Victor
    Munoz, Gonzalo
    Huentequeo, Claudio
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (06) : e534 - e536