A counting silicon microstrip detector for precision compton polarimetry

被引:5
|
作者
Doll, D [1 ]
Fischer, P [1 ]
Hillert, W [1 ]
Krüger, H [1 ]
Stammschroer, K [1 ]
Wermes, N [1 ]
机构
[1] Univ Bonn, Inst Phys, D-53115 Bonn, Germany
关键词
Compton scattering; microstrip detector; polarimetry; polarization;
D O I
10.1016/S0168-9002(02)01396-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A detector for the detection of laser photons backscattered off an incident high-energy electron beam for precision Compton polarimetry in the 3.5 GeV electron stretcher ring ELSA at Bonn University has been developed using individual photon counting. The photon counting detector is based on a silicon microstrip detector system using dedicated ASIC chips. The produced hits by the pair converted Compton photons are accumulated rather than individually read out. A transverse profile displacement can be measured with pm accuracy rendering a polarization measurement of the order of 1% on the time scale of 10-15 min possible. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:356 / 364
页数:9
相关论文
共 50 条
  • [1] Development of a Counting Strip Detector Readout Chip for Precision Compton Polarimetry
    Karagounis, Michael
    Ahluwalia, Gabriel
    Gronewald, Marcus
    Koch, Manuel
    Krueger, Hans
    Wermes, Norbert
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 345 - 352
  • [2] X-ray polarimetry by means of Compton scattering in the sensor of a hybrid photon counting pixel detector
    Michel, T.
    Durst, J.
    Jakubek, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 603 (03): : 384 - 392
  • [3] Design and construction of a Cherenkov detector for Compton polarimetry at the ILC
    Bartels, C.
    Ebert, J.
    Hartin, A.
    Helebrant, C.
    Kaefer, D.
    List, J.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [4] THE BIPOLAR SILICON MICROSTRIP DETECTOR - A PROPOSAL FOR A NOVEL PRECISION TRACKING DEVICE
    HORISBERGER, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01): : 87 - 91
  • [5] Precision Compton polarimetry for the QWeak experiment at Jefferson Lab
    Wouter Deconinck
    Hyperfine Interactions, 2011, 200 : 31 - 34
  • [6] Precision Compton polarimetry for the QWeak experiment at Jefferson Lab
    Deconinck, Wouter
    HYPERFINE INTERACTIONS, 2011, 200 (1-3): : 31 - 34
  • [7] THE SILICON MICROSTRIP DETECTOR
    LITKE, AM
    SCHWARZ, AS
    SCIENTIFIC AMERICAN, 1995, 272 (05) : 76 - 81
  • [8] Ultrahigh-precision Compton polarimetry at 2 GeV
    Zec, A.
    Premathilake, S.
    Cornejo, J. C.
    Dalton, M. M.
    Gal, C.
    Gaskell, D.
    Gericke, M.
    Halilovic, I.
    Liu, H.
    Mammei, J.
    Michaels, R.
    Palatchi, C.
    Pan, J.
    Paschke, K. D.
    Quinn, B.
    Zhang, J.
    PHYSICAL REVIEW C, 2024, 109 (02)
  • [9] DETECTOR CAPACITANCE OF SILICON MICROSTRIP DETECTOR
    IKEDA, H
    TANAKA, M
    OKUNO, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 313 (1-2): : 31 - 36
  • [10] A diamond micro-strip electron detector for Compton polarimetry
    Narayan, A.
    Dutta, D.
    Tvaskis, V.
    Martin, J. W.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2012, 35 (04): : 134 - 136