Anatomic Asymmetry in Sentinel Lymph Node Detection in Endometrial Cancer

被引:6
|
作者
Tal, Ori [1 ]
Grinstein, Ehud [1 ]
Goshen, Elinor [2 ]
Oksman, Yakov [2 ]
Lorberboym, Mordechai [3 ]
Elyashiv, Osnat [1 ]
Ben Shem, Erez [1 ]
Peled, Ofri [1 ]
Levy, Tally [1 ]
机构
[1] Edith Wolfson Med Ctr, Div Gynecol Oncol, Dept Obstet & Gynecol, IL-58100 Holon, Israel
[2] Edith Wolfson Med Ctr, Dept Nucl Med, Holon, Israel
[3] Tel Aviv Univ, Dept Nucl Med, Shamir Med Ctr, Sackler Sch Med, Tel Aviv, Israel
关键词
Anatomic concordance; Indocyanine green; Technetium; INDOCYANINE GREEN; BLUE-DYE; BIOPSY;
D O I
10.1016/j.jmig.2020.12.029
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Study Objective: To determine whether the concomitant use of indocyanine green (ICG) with technetium-99m- filtered sulfur colloid (Tc99m-FSC) improves bilateral sentinel lymph node (SLN) detection rate in endometrial cancer and whether anatomic concordance of pelvic lymph nodes exists and can be used to predict SLN location in cases of unilateral mapping failure. Design: Retrospective cohort study. Setting: Tertiary academic medical center in Holon, Israel. Patients: Patients diagnosed with endometrial cancer, who underwent SLN mapping with Tc99m-FSC, ICG, or both, at our center between 2014 and 2019. Interventions: A total of 111 patients were included in the study. SLN mapping using Tc99m-FSC was performed in 101 (91.9%) patients, and ICG injection was given to 64 (57.6%) patients of whom 55 (49.5%) received both. We compared SLN detection rates (unilateral and bilateral) and anatomic symmetry for each method alone and for a combination of the 2. Measurements and Main Results: The overall detection rate for unilateral SLNs was 96.4%; 96.9% with ICG, 93.1% with gamma-probe, and 98.2% by combining both methods. The total bilateral detection rate was 72.1%, with ICG performing better as a single tracer than Tc99m-FSC (75% vs 63.4%, respectively). In 55 women in whom both tracers were used, the bilateral detection rate was significantly higher compared with Tc99m-FSC alone. Symmetric pelvic anatomic concordance of SLN was found in only 35 of 80 patients with bilateral SLN detection (43.8%). Conclusion: The combination of preoperative radioisotope injection and intraoperative ICG administration may yield the best bilateral SLN detection rate. In cases of unilateral mapping failure, one cannot rely on the anatomic location of the ipsilateral SLN detected to harvest the complementary node because the symmetric concordance is poor. (C) 2020 AAGL. All rights reserved.
引用
收藏
页码:1531 / 1535
页数:5
相关论文
共 50 条
  • [1] Maximizing Sentinel Lymph Node Detection: Aortic Sentinel Lymph Node Detection in Endometrial Cancer
    Gorostidi, Mikel
    Villalain, Cecilia
    Ruiz, Ruben
    Jaunarena, Ibon
    Lekuona, Arantxa
    Diez-Itza, Irene
    [J]. JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2019, 26 (01) : 23 - 24
  • [2] Sentinel lymph node detection in patients with endometrial cancer
    Niikura, H
    Okamura, C
    Utsunomiya, H
    Yoshinaga, K
    Akahira, J
    Ito, K
    Yaegashi, N
    [J]. GYNECOLOGIC ONCOLOGY, 2004, 92 (02) : 669 - 674
  • [3] Sentinel lymph node in endometrial cancer
    Lopes, L. A. F.
    Nicolau, S. M.
    Baracat, F. F.
    Baracat, E. C.
    Goncalves, W. J.
    Santos, H. V. B.
    Lopes, R. G.
    Lippi, U. G.
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2007, 17 (05) : 1113 - 1117
  • [4] Controversy over sentinel lymph node detection in endometrial cancer
    Paredes, P.
    Diaz-Feijoo, B.
    Aguilar Galan, E., V
    de Matias Martinez, M.
    Fuertes Cabero, S.
    [J]. REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2022, 41 (06): : 373 - 379
  • [5] Sentinel lymph node in endometrial cancer: A systematic review on laparoscopic detection
    Abdullah, Nor Anita
    Huang, Kuan-Gen
    Casanova, Joao
    Artazcoz, Santiago
    Jarruwale, Phanida
    Benavides, Doris R.
    Lee, Chyi-Long
    [J]. GYNECOLOGY AND MINIMALLY INVASIVE THERAPY-GMIT, 2013, 2 (03): : 75 - 78
  • [6] Laparoscopic assessment of the sentinel lymph node detection in the patients with endometrial cancer
    Holub, Z
    Jabor, A
    Kliment, L
    [J]. 10TH CONGRESS OF THE EUROPEAN SOCIETY FOR GYNAECOLOGICAL ENDOSCOPY, PROCEEDINGS, 2001, : 327 - 330
  • [7] Indocyanine green sentinel lymph node mapping and detection in endometrial cancer
    Lau, Julio
    Estrada, Erick Estuardo
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2020, 30 (09) : 1460 - 1461
  • [8] Sentinel Lymph node detection in endometrial cancer - Anatomical and scientific facts
    Kimmig, Rainer
    Thangarajah, Fabinshi
    Buderath, Paul
    [J]. BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2024, 94
  • [9] Sentinel lymph node in endometrial cancer: an overview
    Goncalves, Elisabete
    Figueiredo, Odete
    Costa, Fernanda
    [J]. GYNECOLOGICAL SURGERY, 2013, 10 (04) : 231 - 239
  • [10] THE SENTINEL LYMPH NODE TECHNIQUE IN THE ENDOMETRIAL CANCER
    Bouaziz, H.
    Sghaier, S.
    Slimane, M.
    Zabaar, L.
    Bouzaiene, H.
    Rahal, K.
    [J]. BRITISH JOURNAL OF SURGERY, 2021, 108 : 30 - 30