Pedicle Screw Placement With O-arm and Stealth Navigation

被引:36
|
作者
Patil, Suresh [1 ]
Lindley, Emily M. [1 ]
Burger, Evalina L. [1 ]
Yoshihara, Hiroyuki [1 ]
Patel, Vikas V. [1 ]
机构
[1] Univ Colorado, Spine Ctr, Dept Orthopaed, Aurora, CO 80045 USA
关键词
CONVENTIONAL FLUOROSCOPY; IMPROVING ACCURACY; SURGERY; FUSION; INSTRUMENTATION; THRESHOLDS; FIXATION; SPINE;
D O I
10.3928/01477447-20111122-15
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Various navigation systems are available to aid pedicle screw placement. The O-arm replaces the need for fluoroscopy and generates a 3-dimensional volumetric dataset that can be viewed as transverse, coronal, and sagittal images of the spine, similar to computed tomography (CT) scanning. The dataset can be downloaded to the Stealth system (Medtronic Navigation, Louisville, Colorado) for real-time intraoperative navigation. The main objectives of the current study were to assess (1) accuracy of pedicle screw placement using the O-arm/Stealth system, and (2) time for draping, positioning of the O-arm, and screw placement. Of 188 screws (25 patients), 116 had adequate images for analysis. The average time for O-arm draping was 3.5 minutes. Initial O-arm positioning was 6.1 minutes, and final positioning was 4.9 minutes. Mean time for screw placement, including O-arm draping and positioning and array attachment, was 8.1 minutes per screw. Mean time for screw placement alone was 5.9 minutes per screw. Screw placements on final O-arm images were on average 3.14 mm deeper than on the snapshot navigation images. Three screws (2.6%) breached the medial cortex, and 3 screws (2.6%) were misaligned and did not follow the pilot hole trajectory. The use of the O-arm/Stealth system was associated with a low rate of pedicle screw misalignment. The time to place screws was less than previously reported with CT navigation, but longer than conventional techniques. It is important to be aware of the potential discrepancy between snapshot navigation images and actual screw placement on final O-arm images. Our findings suggest that final screw positions may be deeper than awl positions appear on navigation images.
引用
收藏
页码:E61 / E65
页数:5
相关论文
共 50 条
  • [1] Benefits and Pitfalls of O-Arm Navigation in Cervical Pedicle Screw
    Shin, Hong Kyung
    Jeon, Sang Ryong
    Roh, Sung Woo
    Park, Jin Hoon
    [J]. WORLD NEUROSURGERY, 2022, 159 : E460 - E465
  • [2] One-step Minimally Invasive Pedicle Screw Instrumentation Using O-Arm and Stealth Navigation
    Kleck, Christopher J.
    Johnson, Christopher
    Akiyama, Michelle
    Burger, Evalina L.
    Cain, Christopher J.
    Patel, Vikas V.
    [J]. CLINICAL SPINE SURGERY, 2018, 31 (05): : 197 - 202
  • [3] O-arm navigation versus C-arm guidance for pedicle screw placement in spine surgery: a systematic review and meta-analysis
    Weili Feng
    Weihao Wang
    Shubiao Chen
    Kezhou Wu
    Hu Wang
    [J]. International Orthopaedics, 2020, 44 : 919 - 926
  • [4] Clinical and radiographic outcomes of minimally invasive percutaneous pedicle screw placement with intraoperative CT (O-arm) image guidance navigation
    Kim, Terrence T.
    Drazin, Doniel
    Shweikeh, Faris
    Pashman, Robert
    Johnson, J. Patrick
    [J]. NEUROSURGICAL FOCUS, 2014, 36 (03)
  • [5] O-arm navigation versus C-arm guidance for pedicle screw placement in spine surgery: a systematic review and meta-analysis
    Feng, Weili
    Wang, Weihao
    Chen, Shubiao
    Wu, Kezhou
    Wang, Hu
    [J]. INTERNATIONAL ORTHOPAEDICS, 2020, 44 (05) : 919 - 926
  • [6] Risk Factors for the Drift Phenomenon in O-arm Navigation-Assisted Pedicle Screw Placement during Spinal Deformity Surgery
    Zhao, Jianquan
    Jiang, Heng
    Zhuge, Yingjie
    Gao, Rui
    Wang, Ce
    Ma, Jun
    Zhou, Xuhui
    [J]. ORTHOPAEDIC SURGERY, 2023, 15 (01) : 118 - 123
  • [7] O-arm navigation for sacroiliac screw placement in the treatment for posterior pelvic ring injury
    Shengyu Lu
    Keqin Yang
    Cailing Lu
    Ping’ou Wei
    Zhi Gan
    Zhipeng Zhu
    Haitao Tan
    [J]. International Orthopaedics, 2021, 45 : 1803 - 1810
  • [8] O-arm navigation for sacroiliac screw placement in the treatment for posterior pelvic ring injury
    Lu, Shengyu
    Yang, Keqin
    Lu, Cailing
    Wei, Ping'ou
    Gan, Zhi
    Zhu, Zhipeng
    Tan, Haitao
    [J]. INTERNATIONAL ORTHOPAEDICS, 2021, 45 (07) : 1803 - 1810
  • [9] O-Arm Assisted Cervicothoracic Spine Pedicle Screw Placement Accuracy Is Higher Than C-Arm Fluoroscopy
    Inoue, Tomohisa
    Wada, Keiji
    Tominaga, Ayako
    Tamaki, Ryo
    Hirota, Tomoya
    Okazaki, Ken
    [J]. WORLD NEUROSURGERY, 2022, 158 : E996 - E1001
  • [10] The Accuracy of Intraoperative O-arm Images for the Assessment of Pedicle Screw Postion
    Santos, Edward R. G.
    Ledonio, Charles G.
    Castro, Carlos A.
    Truong, Walter H.
    Sembrano, Jonathan N.
    [J]. SPINE, 2012, 37 (02) : E119 - E125