Improved separation by at-column dilution in preparative hydrophilic interaction chromatography

被引:3
|
作者
Jaffuel, Geoffrey [1 ]
Chappuis, Laura [1 ]
Guillarme, Davy [2 ]
Turlings, Ted C. J. [1 ]
Glauser, Gaetan [3 ]
机构
[1] Univ Neuchatel, Fac Sci, FARCE Lab, Rue Emile Argand 11, CH-2000 Neuchatel, Switzerland
[2] CMU, Univ Lausanne, Univ Geneva, Sch Pharmaceut Sci, Rue Michel Servet 1, CH-1206 Geneva, Switzerland
[3] Univ Neuchatel, Fac Sci, Neuchatel Platform Analyt Chem, Ave Bellevaux 51, CH-2000 Neuchatel, Switzerland
基金
瑞士国家科学基金会;
关键词
HPLC; Preparative chromatography; HILIC; At-column dilution; Efficiency; Peak capacity; INTERACTION LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; EXTRACTS; STRESS;
D O I
10.1016/j.chroma.2017.11.071
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We evaluated at-column dilution (ACD), as a possible approach to reduce peak distortion caused by the injection of strong solvents in preparative hydrophilic interaction chromatography (HILIC). Three model compounds, namely uridine, cytidine and guanosine were selected and injected either in conventional or ACD conditions, using various proportions of water and acetonitrile in the sample diluent. Plate number and peak capacity were systematically investigated under both isocratic and gradient elution conditions, respectively. In isocratic conditions, ACD was found to provide higher plate numbers with sample diluent containing more than 40% water, but lower plate numbers with injections of less than 40% water, in comparison to a conventional injection system at the preparative scale. These contrasting results were attributed to the fact that i) efficiency was fundamentally reduced in ACD, due to the low make-up flow rate that was used to flush the injection loop, but ii) the trend was reversed for highly aqueous injection thanks to the capacity of ACD to maintain similar efficiency regardless of the injection solvent. On the other hand, peak capacity was comparable between ACD and conventional systems in gradient elution for injections containing low amounts of water. However, ACD became increasingly advantageous as the proportion of water in the injection solvent and/or the injection volume increased. This was confirmed by the separation of a plant root aqueous extract. Altogether, our findings suggest that ACD is beneficial both in isocratic and gradient modes when strongly aqueous solutions are injected, offering an attractive approach to increase loadability, while preserving peak shapes in preparative HILIC. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:136 / 143
页数:8
相关论文
共 50 条
  • [1] At-column dilution for improved loading in preparative chromatography
    Neue, UD
    Mazza, CB
    Cavanaugh, JY
    Lu, Z
    Wheat, TE
    [J]. CHROMATOGRAPHIA, 2003, 57 (Suppl 1) : S121 - S127
  • [2] At-column dilution for improved loading in preparative chromatography
    U. D. Neue
    C. B. Mazza
    J. Y. Cavanaugh
    Z. Lu
    T. E. Wheat
    [J]. Chromatographia, 2003, 57 : S121 - S127
  • [3] Carbohydrate separation by hydrophilic interaction liquid chromatography on a 'click' maltose column
    Fu, Qing
    Liang, Tu
    Zhang, Xiuli
    Du, Yuguang
    Guo, Zhimou
    Liang, Xinmiao
    [J]. CARBOHYDRATE RESEARCH, 2010, 345 (18) : 2690 - 2697
  • [4] Lignosulfonate Separation Using Preparative Column Chromatography
    Ouyang, Xinping
    Zhang, Pan
    Qiu, Xueqing
    Deng, Yonghong
    Chen, Pu
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2011, 50 (18) : 10792 - 10799
  • [5] IMPROVED PREPARATIVE DRY-COLUMN CHROMATOGRAPHY
    MENDEL, A
    [J]. JOURNAL OF CHROMATOGRAPHY, 1973, 87 (01): : 236 - 238
  • [6] Separation of nucleotides by hydrophilic interaction chromatography using the FRULIC-N column
    Nilusha L. T. Padivitage
    Milan K. Dissanayake
    Daniel W. Armstrong
    [J]. Analytical and Bioanalytical Chemistry, 2013, 405 : 8837 - 8848
  • [7] Separation of nucleotides by hydrophilic interaction chromatography using the FRULIC-N column
    Padivitage, Nilusha L. T.
    Dissanayake, Milan K.
    Armstrong, Daniel W.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (27) : 8837 - 8848
  • [8] PREPARATIVE SEPARATION OF PLASMA LIPOPROTEINS BY AGAROSE COLUMN CHROMATOGRAPHY
    RUDEL, L
    MORRIS, M
    LEE, J
    FELTS, J
    [J]. CIRCULATION, 1972, 46 (04) : 17 - &
  • [9] COLUMN CHROMATOGRAPHY ON TRIACETYLCELLULOSE - PREPARATIVE SEPARATION OF ENANTIOMERIC DIAZIRIDINES
    HAKLI, H
    MANNSCHRECK, A
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1977, 16 (06): : 405 - 406
  • [10] Separation efficiencies in hydrophilic interaction chromatography
    Ikegami, Tohru
    Tomomatsu, Kouki
    Takubo, Hirotaka
    Horie, Kanta
    Tanaka, Nobuo
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) : 474 - 503